Sherhan magicar a instruction manual. Car alarm sherkhan magicar a instruction manual. All technical features

Car alarm Sherkhan MAGICAR A INSTRUCTION MANUAL

MAGICAR A

MANUAL

SCHER-KHAN MAGICAR A FUNCTION

The SCHER-KHAN MAGICAR A system is a car alarm system with the ability to be controlled via a radio channel using a key fob-communicator with a liquid crystal display. The system exchanges information between the key fob-communicator and the processor unit at a distance of up to 800 m. The system is designed to work on gasoline or diesel vehicles with a fuel injection system and an on-board network voltage of 12V. The protection of the processor unit, shock sensor, call sensor, antenna unit is made according to the IP-40 standard and provides for installation in the car. The siren is IP-65 rated and can be installed in the engine bay away from the exhaust manifold and high voltage systems.

KEY FOB COMMUNICATOR FUNCTIONS

  • Multifunctional, 4-button LCD keychain communicator
  • Protection against interception of MAGIC CODE code packets
  • Audiovisual confirmation of executed commands
  • Vibrating bell
  • Loud beeps
  • Ultra long distance communication up to 800 m with processor unit
  • Automatic display backlight
  • Low battery indication
  • Vehicle battery voltage indication
  • Indication of temperature in the passenger compartment
  • Current time indication
  • Indication of engine operating time in automatic mode
  • Remote engine start
  • Programming the engine start time (accurate to the minute)
  • Sound and visual alert reminder mode
  • Operational, from the key fob, programming of all system functions
  • Economy Power (one AAA element)

PROCESSOR UNIT FUNCTIONS

  • Automatic engine start for vehicles with automatic or manual transmission
  • Operation of the starting system with both petrol and diesel engines
  • Operation of the starting system with engines having a turbine
  • Starting the engine on command from the key fob
  • Automatic engine start every 2 hours
  • Automatic engine start at a pre-set time every 24 hours
  • Monitoring the engine start by signals from the generator or by noise in the on-board network
  • Personal code for access to the car interior if the key is lost
  • Power output for controlling the car's central locking
  • Trunk release power output
  • Alarm control power output (two circuits)
  • Programming the lock relay type
  • Auto arming (programmable function)
  • Sound warning before automatic arming
  • Automatic return to armed mode if the door was not opened
  • Sound warning before automatic return to armed mode
  • Armed mode without siren signals
  • Two universal programmable control channels for additional devices
  • Ability to connect negative and positive door sensors
  • Input for negative trunk sensor
  • Locking and unlocking the door locks when starting and stopping the engine
  • Possibility of arming with and without confirmation siren signals
  • Open Door Alarm Warning (Programmable)
  • Panic or JackStop mode
  • Highly sensitive two-level shock sensor with sensitivity adjustment
  • Parking lights not switched off warning

TECHNICAL SPECIFICATIONS

Alarm types:
Influence on the main and additional electrical equipment of the car
STSTS controls the power supply to: Maximum current per channel
Starter or ignition interlock circuit Imax = 0.2 A
Port Alarm Circuit Imax = 10 A
Starboard Alarm Circuit Imax = 10 A
Ignition circuit Current Imax = 30 A
Accessory chain Current Imax = 30 A
Starter circuit Current Imax = 30 A
Ignition circuit 2 Current Imax = 0.2 A
Additional siren Current Imax = 2 A
Relay for unlocking electric door locks or unlocking the standard system of the Central locking (CL) of the car Current Imax = up to 15 A
Relay for controlling the locking of electric door locks or locking the standard system of the Central lock (CL) of the car Current Imax = up to 15 A
Power trunk lock relay Current Imax = 10 A
Auxiliary device control channel 1 Current Imax = 0.2 A
Option control channel 2 Current Imax = 0.2 A
The channel for disarming the STSTS standardly installed on the car Current Imax = 0.2 A
Control methods
  • Remotely with a radio frequency transmitter (key fob) at a frequency of 433.92 MHz ± 0.2% with a power of not more than 10 mW
  • From the ignition key
  • Automatically based on signals from sensors
Electrical circuit protection

Fuses. (Automotive slow-acting fuses according to wiring diagram)

Spheres of protection
Other parameters
Batteries

* Note: The table shows the average value. The service life of the key fob battery depends on the intensity of use of the key fob and the quality of the battery, the key fob operation modes.

ATTENTION! Use only quality batteries. The use of a poor quality battery can lead not only to a reduction in the life of the key fob, but also to its damage.

KEYFOB COMMUNICATOR

PREPARING THE KEYFOB-COMMUNICATOR FOR WORK

Before using the key fob, you must bring it into working condition, because. during transportation and storage, an insulating gasket is installed between the contact of the battery and the contact plate of the key fob, which prevents the battery from discharging before operation. Before using the key fob, remove it. To do this, release the battery cover lock, press the cover and slide it in the direction opposite to the antenna. Remove the battery. Remove the insulating pad between the battery and the collector plate. Install the battery back, observing the polarity indicated on the bottom of the battery compartment. Close the battery cover. Keyring is ready to go.

SYMBOLS ON THE DISPLAY OF THE KEY FOB COMMUNICATOR
Timer start indicator
TURBO mode indicator
Passive arming indicator
Siren indicator
Shock sensor off indicator
Vibrating alert indicator
Indicator of turning on the automatic control of the central lock by ignition
Door open indicator
Trunk/hood open indicator
Shock sensor alarm indicator (optional sensor)
Car owner call indicator
Engine running indicator
Ignition on indicator in security mode, indicator of side lights not switched off
Key fob transmitter operation indicator
Battery discharge indicator of the key fob-communicator
VALET mode indicator
Locking and unlocking indicator. Security Mode Status Indicator
Purpose of the keyfob-communicator buttons

Example notation:

I - quick (0.5 sec.) button press
I- - long (2 sec.) button press
(I + II) - fast (0.5 sec.) simultaneous pressing of the buttons (combination of buttons)
(I + II) - - long (2 sec.) simultaneous pressing of the buttons (combination of buttons)

Control channel number Button number Press duration Executed function (mode)
1 I 0.5 sec.
  • Enable / disable security mode
  • Enable/disable call mode
  • Stop alarm mode
  • Enable/disable starter/ignition interlock
2 (III+IV) - 2 sec. Recording and playback of a fragment on the voice module (Option)
3 II 0.5 sec. Additional channel control 1
4 III 0.5 sec. Additional channel control 2
5 IV 0.5 sec. Checking System Status
6 II- 2 sec. Starting and stopping the engine from the key fob
7 III- 2 sec. open trunk
8 IV- 2 sec. "Panic". To stop, press the I button
9 (I+II) 0.5 sec. Siren on/off
10 (I+III) 0.5 sec. "Valet" mode enable/disable
11 (I+IV) 0.5 sec. Automatic control of the central lock by ignition on / off
12 (II+III) 0.5 sec. Automatic arming enable/disable
13 (II+IV) 0.5 sec. Timer start enable/disable
14 (III+IV) 0.5 sec. Turbo mode enable/disable
15 (I+III)- 2 sec. Shock sensor enable/disable
18 (I+II)- 2 sec. Enter programming menu 1
19 (I+IV)- 2 sec. Enter programming menu 2
Setting the time on the keyfob-communicator display

Setting the current time is required before starting the operation of the system or when changing the key fob battery. Follow the steps according to the table below.

Execution steps Press duration Executed function (mode)
STEP 1 (II+III)- 2 sec.
STEP 2 I 0.5 sec. Turn on the current time setting mode. The indications of the current time are flashing (confirmed by the sound signal of the key fob)
STEP 3 I 0.5 sec. Changing the value of the clock
II 0.5 sec. Changing the minutes
STEP 4 (II+III)- 2 sec.

ATTENTION! Setting the exact time is a prerequisite for the correct operation of the automatic engine start by timer.

Setting the keyfob-communicator, vibration call, owner call, temperature display standard "°F" or "°С"

To set the desired key fob operation mode, follow the steps in accordance with the table below.

Execution steps Button number or combination of buttons Press duration Executed function (mode)
STEP 1 (II+III)- 2 sec. Entering the keyfob function programming mode. The appearance of the symbol is confirmed by a beep from the key fob.
STEP 2 III 0.5 sec. Activate the call mode from the car. The symbol appears or disappears. Confirmed by a beep from the key fob
IV 0.5 sec. Turning on the vibration signal of the key fob. The symbol appears or disappears. Confirmed by a beep from the key fob
(I+IV) 0.5 sec. Changing the temperature display "°F" or "°C"

Note: STEP 2 must be completed within 15 seconds. after STEP 1.

Arming [Button (I)]

Close doors, hood, trunk. Briefly press button I on the key fob. The system will switch to the armed mode, the door locks will be locked, the starter (ignition) interlock will turn on until the system is disarmed.


When arming:

Enable sensors:

  • Immediately after the LED starts flashing, the system begins to monitor the status of the doors, hood, trunk, call sensor of the owner of the car.
  • The shock sensor will turn on after 30 seconds. after arming.

Note: If, when arming, you heard three signals from the key fob, and on the display for 5 seconds. the image of an open door or trunk flashes, this means that the door, hood / trunk is open in the car. The door, hood/trunk sensor will be immediately armed when its functionality is restored. The hood area is not displayed separately, the hood sensor must be connected to the trunk sensor wire.

Disarming [Button (I)]

When the system is armed, briefly press button I on the key fob. The system will be disarmed, the door locks will be unlocked, the starter (ignition) interlock will be disabled.


When disarming:

Starting the engine on command from the key fob [Button (II) -]

To start the engine, press button II on the key fob for 2 seconds. The system will be armed, the door locks will be locked, the car engine will start. After the engine has started, the keyfob-communicator displays information about the time remaining until the end of engine operation in automatic mode. Engine run time is programmable and can be 15/25/45/5 minutes (programmable function 2-4).

To start driving. you need to open the door, insert the ignition key into the lock and turn it to the "ON" position. To do this, you have 20 seconds, after this time the system will transfer control to the ignition switch, if you do not turn on the ignition, the engine will be stopped. If the launch did not occur the first time, the system will try again. The system makes no more than three attempts to start, after which it goes into standby mode. If the car engine does not start after the last attempt, contact a service station to diagnose your car.

At the time of launch:

The system will not start the engine if:

  • Ignition on
  • The car engine is already running
  • Door or hood/trunk open
  • Backup mode failed for vehicles with manual transmission

On successful launch:

Note: If the car's engine is started automatically, the current time indicator shows the time remaining until the engine is stopped. Time is displayed in countdown mode. Time display format in this mode: [ XX min: XX sec.]

When the engine stops automatically:

Trunk opening [Button (III)-]

Press and hold for 2 sec. key fob button III, after which the trunk will open. If the system is armed (doors locked), it will disarm, the doors will unlock, and the starter will be disabled. To implement this function, it is necessary to have a trunk lock solenoid connected to the corresponding output of the main unit of the system.


When opening the trunk:

Checking System Status [Button (IV)]

If you need to check the status of the system, briefly press the button IV of the keyfob-communicator. Information about the state of the system will be shown on the keyfob-communicator display, as well as confirmed by siren and alarm signals.

When checking system status:

When checking the status of the system, the current time indicator shows the temperature value in the car interior. The temperature can be displayed in either °F or °C The temperature inside the vehicle is 10°C.


Repeated short pressing of the button IV of the keyfob-communicator within 6 seconds after the first one allows you to view information about the car battery voltage in volts. The voltage on the car battery is 13.9V.


Panic Mode or JackStop™ (anti-grab) [Button (IV)-]

When you press the button N of the key fob for 2 seconds. the system will enter Panic mode or JackStop™ (protection against capture) - programmable function 1-4.. If the system was disarmed, it will arm itself, the door locks will be locked. The siren will sound for 90 seconds, the alarm will flash for 90 seconds. The "Panic" mode stops the automatic engine start mode. After 90 sec. the system will go into armed mode until it is disarmed by the key fob or emergency shutdown mode. Panic mode can be stopped with a short press of the I button. Panic and JackStop™ modes are used in case of danger or when it is necessary to draw attention to the vehicle.

When activating Panic and JackStop™ modes:

Differences in the Panic and JackStop™ algorithms (depending on the selected value of the programmable function 1-4):

ATTENTION! The JackStop™ mode should only be used in an emergency. It is not a regular constantly used STSTS mode, because. it provides for stopping the engine while driving.

When choosing one or another mode, consult with a specialist.

Siren Silence [Button (I+II)]

By briefly simultaneously pressing the buttons I + II of the key fob, you can turn on or turn off the siren signals. In this case, the key fob signals and alarm signals will work as usual. The siren activation is indicated by the presence of a symbol on the key fob display.


When the siren is turned on:

When turning off the siren signals:

VALET mode [Button (I+III)]

To disable the security functions of the system and when transferring the machine to a service station for maintenance, you can use the VALET mode. To do this, briefly press the buttons I + III of the key fob.

In VALET mode, you can control the locking and unlocking of the door locks. To lock or unlock the locks, briefly press button I.

The VALET mode is shown on the display with the symbol

To exit the VALET mode, briefly press the buttons I + III of the key fob


When VALET mode is enabled:

When turning off VALET mode:

Disabling the two-level shock sensor [Button (I+III)]

You can disable the two-level shock sensor. Simultaneously press and hold for 2 seconds. buttons I + III of the keyfob, as a result, the sensors will be turned on or off. The indication of the sensor disconnection is the symbol on the key fob display. Switching off the sensor is necessary if you leave the car where false alarms are possible (the car is parked near tram tracks, a child or an animal remains in the car).


When the shock sensor is disabled:

When the shock sensor is turned on:

The shock sensor is called two-level, because it has two levels of response from the impact on the car.

In case of a weak impact, the system warns with 4 short siren sounds and 4 alarm flashes. Key fob - communicator gives a short tone signal, the symbol of impact on the car flashes on the display. If the impact is strong, the system goes into alarm mode for 30 seconds.

Central locking control for turning the ignition on and off [Button (I + IV)]

By briefly simultaneously pressing the buttons I + IV of the key fob, you can turn on or turn off the automatic control of the central lock (CL) by turning the ignition on and off. If the function is enabled, the door locks will be automatically locked after 30 seconds. after the engine is started and all doors, the hood/trunk will be closed. The locks are unlocked immediately when the ignition is switched off. The function activation is indicated by the presence of a symbol on the key fob display.


When the central locking control function from ignition is turned on:

When the central locking control function is turned off from the ignition:

Passive arming [Button (II+III)]

The passive arming function can be turned on/off by briefly pressing the buttons II+III of the key fob. When passive arming is enabled, the system will automatically arm itself after 30 seconds. after closing the last door or after disarming with the key fob. The system warns of passive arming with alarms and (or) siren every 10 seconds. If within 30 sec. doors (hood/trunk) were opened, the system will arm itself in 30 seconds. after closing the doors (hood/trunk).


When passive arming is enabled:

When turning off passive arming:

Setting the timer for automatic engine start [Button (II+IV)]

Briefly press the buttons II + IV of the key fob to turn the engine start on or off by timer. The indication of the inclusion of starting the engine by timer is the presence of the label "TIMER" on the key fob display. The system provides two modes of starting the engine by timer. The first mode allows you to start the engine every day at a predetermined time, the second mode allows you to start the engine periodically, every 2 hours to warm up (or cool the interior in countries with a hot climate). Two modes cannot be used at the same time, the mode you need can be selected by programmable function 2-3


To automatically start the engine by timer at the right time (24 hours), it is necessary to make a reservation for this mode. For this:

  1. Select start time (see table)
  2. Press the buttons II + IV and turn off the label "TIMER"
Execution steps Button number or combination of buttons Press duration Executed function (mode)
STEP 1 (II+III)- 2 sec. Entering the keyfob function programming mode. The appearance of the symbol is confirmed by a beep from the key fob.
STEP 2 II 0.5 sec. Turn on the timer setting mode. The indications of the previously set time are flashing (confirmed by the sound signal of the key fob)
STEP Z I 0.5 sec. Changing the value of the clock
II 0.5 sec. Changing the minutes
STEP 4 (II+III)- 2 sec. Exit from the programming mode of the key fob functions. Confirmed by a beep from the key fob

In order to enable or disable the engine start by timer every 2 hours, briefly press the buttons II + IV of the key fob. Setting the start time in this mode is not required, the first engine start will occur 2 hours after the mode is turned on.

When the timer engine start is enabled:

When turning off the engine start by timer:

Note: Automatic start of the engine by timer every 24 hours is useful for starting the engine every day at a certain time if your car is parked outside the range of the key fob.

ATTENTION! The engine start time according to the 24 hour timer can be shifted up to ±2 minutes per day.

TURBO Mode [Button (II+IV)]

If the car has a Turbo-engine, then after a long operation at high speeds it is not recommended to stop it immediately. The engine should idle for some time to cool the turbine. For this, the SCHER-KHAN MAGICAR A system has a TURBO mode (turbo timer). If the TURBO mode is on, then at the end of the trip the engine will run for 2 minutes. To enable or disable the TURBO mode, briefly press the buttons III + IV of the key fob.


When TURBO mode is enabled:

When turning off the TURBO mode:

To activate the mode at the end of the trip, do the following:

  1. Put the gear lever in neutral or "P" position.
  2. Turn the ignition key from the ON position to the OFF position. The engine will continue to run after this for another 2 minutes.
  3. Get out of the car, close the doors. As soon as the doors are closed, the alarm will flash

Now you can arm the system. The engine will then run until the expiration of 2 minutes. interval. When the car is armed, the door, hood/trunk sensors, the driver call sensor are immediately armed, and the shock sensor will start working after the engine stops. The engine will be immediately stopped when the door, hood/trunk sensor is triggered, and the system will go into alarm mode. If necessary, you can urgently stop the engine by pressing for 2 seconds. key fob button II.

Auxiliary channel 1 control [Button (II)]

If your car is equipped with an electromechanical hood lock, an additional starting heater or other service equipment, you can control the operation of these devices using a key fob. To do this, briefly press button II on the key fob. A short or long signal will appear at the output of additional channel 1 of the processor unit (programmable function 2-5). The siren and parking lights signals will differ when controlling an additional channel, depending on the state of the programmable function 2-5. If a channel is programmed to beep continuously (Programmable Function Value 4 2-5), the system will confirm its activation and deactivation with siren and alarm signals. If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel. The additional channel does not work in the VALET mode and in the alarm mode.

Note: If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel (programmable function 2-5)

Auxiliary channel 2 control [Button (III)]

If your car is equipped with an electromechanical hood lock, an additional starting heater or other service equipment, you can control the operation of these devices using a key fob. To do this, briefly press button III on the key fob. A short or long signal will appear at the output of additional channel 2 of the processor unit (programmable function 2-6). The siren and parking lights signals will differ when controlling an additional channel, depending on the state of the programmable function 2-6. If a channel is programmed for a long beep (Programmable Function Value 4 2-6), the system will confirm its activation and deactivation with siren and alarm signals. If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel.

The additional channel does not work in the VALET mode and in the alarm mode.

Turning on an additional channel:

Turning off the additional channel:

Note: If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel (programmable function 2-6)

Alarm mode

If the door, hood/trunk is opened in armed mode, the system will go into alarm mode for 30 seconds, alarms and sirens will last 30 seconds. At the end of 30 sec. the system will return to armed mode. If the shock sensor alarm zone is triggered (strong impact), the system will go into alarm mode for 15 seconds, the alarm and siren signals will last 15 seconds. At the end of 15 sec. the system will return to armed mode. When the warning zone of the shock sensor is triggered (weak impact), the system will not go into alarm mode, but will only issue a series of four short signals by a siren and an alarm. You can stop the alarm mode by short pressing the keyfob button I. The locks will not be unlocked, and the system will switch from alarm mode to armed mode.

In alarm mode:

Reminder mode

If the communicator keyfob received an alarm signal on the door, hood/trunk, shock sensor, call sensor, and you did not notice it immediately, then the keyfob, after the alarm is transmitted, goes into reminder mode (short beeps and indication of the zone that caused the alarm mode ). To stop the reminder mode and check the state of the car, briefly press the button IV of the key fob or button I to exit the security mode and unlock the door locks.

In reminder mode:

Note: Keyfob communicator does not go into reminder mode when receiving a warning signal from a shock sensor (weak impact)

Car Owner Call

If you need to call the owner of the car, tap with a hard object (coin, keys, etc.) near the call sensor. The call sensor LED will flash green. The function of calling the owner of the car is available immediately after arming.

To stop the signals of the keyfob-communicator, press the button I of the keyfob. To stop the signals from the keyfob-communicator and check the condition of the car, briefly press the IV button.


When calling the car owner:

Access to the car without a key fob

Access to a car without a key fob may be required in a number of cases. For example, if the key fob is lost, if the battery in the key fob is dead, if you are relaxing on the beach and do not want to take the key fob with you (the key fob and keys are closed in the car). The SCHER-KHAN MAGICAR A system provides such an opportunity. To ensure that only you are allowed access, the system uses a personal code consisting of four digits. The value of each digit of the code can vary from 1 to 9. Thus, the code can have a value from 1111 to 9999. The code is entered and recorded through the call sensor of the car owner.

Recording a personal code:

In order for you to use this function, you must enter your code into the system memory. To do this, follow several steps:

  1. Turn on the ignition
  2. open the door
  3. While the LED is flashing, tap the call sensor the number of times corresponding to the first digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  4. While the LED is flashing, tap the call sensor the number of times corresponding to the second digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  5. While the LED is flashing, tap the call sensor the number of times corresponding to the third digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  6. While the LED is flashing, tap the call sensor the number of times corresponding to the fourth digit of the code. After 1.5 sec. The LED will confirm the selected number with red flashes.
  7. You will hear one siren tone to confirm that the code has been programmed, and the alarm will flash once.

If you made a mistake on any of the steps, then you need to record the code, starting from point 1.

Entering a personal code:
  1. Tap the call sensor 10 times. Each time the LED in the sensor will flash green. The time between blows must be less than 1.5 seconds.
  2. The LED will quickly flash red to confirm that the previous step has been completed. If the LED does not flash red, then start from step 1 again.
  3. While the LED is flashing, tap the call sensor the number of times corresponding to the first digit of the code. After 1.5 sec. the LED will confirm the entry of the first digit with red flashes and start flashing again.
  4. While the LED is flashing, tap the call sensor the number of times corresponding to the second digit of the code. After 1.5 sec. the LED will confirm the entry of the second digit with red flashes and start flashing again.
  5. While the LED is flashing, tap the call sensor the number of times corresponding to the third digit of the code. After 1.5 sec. the LED will confirm the entry of the third digit with red flashes and start flashing again.
  6. While the LED is flashing, tap the call sensor the number of times corresponding to the fourth digit of the code. After 1.5 sec. the LED will confirm the entry of the fourth digit with red flashes.
  7. If the code is entered correctly, the system will disarm, the door locks will open, and the key fob-communicator will receive a signal to disarm the system.

If the code is entered incorrectly, then the key fob will receive a call signal from the owner, and it will be necessary to repeat all the actions starting from point 1. The system allows five attempts to enter the code within 30 minutes. If the code was entered incorrectly, then its entry is blocked for 24 hours or until you disarm the system using the key fob.

Battery protection (out-of-dimension warning)

The system helps protect the car's battery from being discharged. If you forgot to turn off the parking lights, then when arming, the key fob-communicator will give a series of beeps for 5 seconds. At this time, the images of the lock and side lights will flash on the display. The warning tone will repeat every 30 seconds. three times.

Starter or ignition lock

The system in armed mode will not allow you to start the car engine. When you try to start the engine in armed mode, the system will send an alarm signal to the key fob communicator. An alarm about turning on the ignition will be displayed by flashing side lights on the key fob communicator, sound and vibration signal. The engine blocking operation mode is selected when the system is installed at a service station and depends on the values ​​of two programmable functions 1-4 and 1-8. You can find out more about blocking the engine of your car at the place where the system is installed. When the starter interlock is selected, the system will prevent the vehicle's starter from restarting if the engine is started in automatic mode.

Open door warning

The system warns of an open door (programmable function 1-2). When a custom function value is selected, the alarm flashes if the car door is open.

Protection of the radio channel from code interception

The system has special protection for the commands transmitted by the key fob. Each time you press a button on the system's key fob, the code message changes according to a special algorithm. This is done to protect the system from interception of the code and its selection (intelligent hacking of the security system). The code protection algorithm is specially designed for the SCHER-KHAN MAGICAR system and is unique, not used in any security system of other brands.

Motor protection in automatic start mode

The system in automatic start mode constantly monitors the operation of the engine. If the engine stops before the end of the warm-up cycle (engine failure or out of fuel), then no later than 20 seconds. the processor unit of the system will turn off the ignition. Repeated automatic start of the engine will not be possible until the malfunction is eliminated. For vehicles with a manual transmission, you must perform the backup mode again.

Shock sensor sensitivity adjustment

You can adjust the sensitivity of the shock sensor depending on your requirements. A regulator is provided to adjust the sensitivity of the sensor. Turning the knob clockwise increases the sensitivity, and counterclockwise decreases it until the sensor turns off. Consult a service station about the location of the shock sensor, it must be easily accessible for adjustment.

Adjusting the sensitivity of the owner's call sensor

You can adjust the sensitivity of the car owner's call sensor depending on your requirements. To adjust the sensitivity on the sensor, a step regulator with three positions is provided. The extreme left position of the regulator corresponds to the minimum sensitivity of the sensor, the extreme right - to the maximum. The sensor should be located in the lower corner of the car's windshield.

Adjusting the volume of siren confirmation signals

You can adjust the volume of the siren's short beeps. To reduce the volume, you need to cut the loop from the wire on the siren's body. The system can be equipped with any siren according to the wishes of the owner, including those where there is no possibility of adjustment.

Backup mode (only for manual transmission)

The standby mode excludes the possibility of automatic starting of the engine if the manual transmission lever is not set to the neutral position. Depending on your requirements, you can choose one of three redundancy algorithms (programmable function 1-6).

Algorithm 1

Algorithm 2

To perform a backup (prepare the vehicle for the subsequent automatic start of the engine), do the following:

  1. At the end of the trip, without turning off the engine, place the gear lever in neutral position
  2. Close the hood/trunk doors
  3. Remove the key from the ignition switch (in the OFF position). The engine will keep running
  4. Open the door and get out of the car. Close the door. The engine will stall.

Opening the door after completing the fifth step will make it impossible to automatically start the engine. Diagnosis of the reasons for its failure is described below.

If at least one step from the above algorithm is not performed, then there will be no backup mode and automatic engine start will not occur. In this algorithm, redundancy will be prohibited if the door, hood / trunk are open at the time the ignition is turned off.

Algorithm 3

To perform a backup (prepare the vehicle for the subsequent automatic start of the engine), do the following:

  1. At the end of the trip, without turning off the engine, place the gear lever in neutral position
  2. Close the hood/trunk doors
  3. Press for 2 sec. key fob button II
  4. Remove the key from the ignition switch (in the OFF position). The engine will keep running
  5. Open the door and get out of the car. Close the door. The engine will stall.

Opening the door after completing the fifth step will make it impossible to automatically start the engine. Diagnosis of the reasons for its failure is described below.

If at least one step from the above algorithm is not performed, then there will be no backup mode and automatic engine start will not occur. In this algorithm, the implementation of the reservation requires you to each time press button II of the key fob before turning off the ignition (by turning the key in the ignition switch to the OFF position).

ATTENTION!

Close the sunroof and windows before leaving the vehicle.
Do not leave people or animals in the vehicle when the reservation mode is being executed.
Do not start the engine automatically if there are people or animals in the car. Leave the gear lever always in the neutral position.
Do not use automatic engine start on open top vehicles.
If the operation of the redundancy mode differs from the described algorithms or does not occur, urgently contact a service station for advice. Until the causes of malfunction are eliminated, do not use automatic engine start.

PROGRAMMING NEW KEYFOBS

The system can remember the codes of three key fobs. To program new key fobs, follow two steps.

  1. Turn the ignition key three times from OFF to ON. The alarm will flash once to confirm entry into programming mode.
  2. Not later than 4 sec. after the alarm flashes, press button I of the key fob, the code of which must be entered into the memory of the processor unit.

To exit the programming mode, do not take any action for 4 seconds. after writing the code of the last key fob.

If no action is taken after step 1, then after 4 seconds. the alarm will flash 2 times, the system will switch from the key fob programming mode to the VALET mode.

Note: the system has three memory cells for storing key fob codes. When you try to write the fourth key fob, the code of the first recorded key fob will be deleted.

PROGRAMMING FUNCTIONS USING THE KEYFOB

Programming the CTCTS functions using a key fob consists of four steps.

  1. Entering the programming mode and selecting the programming menu. To enter Menu No. 1, press the I + II buttons simultaneously for 2 seconds. To enter Menu No. 2, press the I + IV buttons simultaneously for 2 seconds. The siren will sound one short beep and the alarm will flash once, confirming the successful completion of STEP 1.
  2. Press the IV button to select the Menu function you want to change. The number of presses must correspond to the number of the selected function. For example, to select function 4, you need to briefly press the keyfob button IV four times. Each button press will be confirmed by a short siren tone (if enabled) and an alarm flash.
  3. Wait a few seconds. The system will confirm the number of the selected function to be changed with short siren sounds and alarm flashes. The number of signals will correspond to the number of the selected function.

    Note: If, when choosing a function, you made a mistake with the number of clicks and (or) there are no siren and alarm signals, then you must repeat all the steps starting from STEP 1.

  4. Press the I button to select the factory setting for the function. To confirm this, the siren will give one short signal, the alarm will flash once. Press the II, III, or IV button to select optional function values. To confirm this, the siren will give two, three or four short beeps, the alarm will flash two, three or four times.

Note: If you hear one long siren signal, this means the system has exited the function programming mode. To continue programming, repeat all steps from STEP 1.

ATTENTION!

If you need to change more than one function from the Menu you have selected, then the selection of each function to change must begin with STEP 1.

Menu of programmable functions

Menu #1 [Button (I+II)-]

No. p / p Function [Button (I)] Factory setting [Button (II)] [Button (III)]
1-1 Delay before the starter rotates after the ignition is turned on. Should be increased for a diesel vehicle. 4 sec. 10 sec.
1-2 Open door warning Not There is
1-3 The duration of the control pulse of the central lock. Should be increased for pneumatic central locking system 0.8 sec. 4 sec.
1-4 Panic mode or JackStop™ (robbery protection) "Panic" (Starter lockout) JackStop™ (Ignition Interlock)
1-5 Central locking control for turning the ignition on and off Turned off Turned off
1-6 Launch reservation method. (Only for manual transmission) Automatically, every time the ignition is turned off Automatically, whenever the ignition is turned off, but provided that the doors are closed Only manual mode, before switching off the ignition for reservation, it is necessary to press button II for 2 seconds.
1-7 Starter rotation time Standard Standard + Minimum Standard + maximum
1-8 Interlock relay type NZ HP

Note on function 1-4: This function allows you to select Panic mode or JackStop™ mode (robbery protection):

Resetting all programmable functions of Menu No. 1 to factory defaults
  1. Entering programming mode. Press buttons I+II simultaneously for 2 sec. The siren will sound one short beep and the alarm will flash once, confirming the success of STEP 1
  2. Briefly press button III on the key fob three times. Each press will be confirmed by a short siren tone and an alarm flash.

After some time, three siren sounds will sound, the alarm will flash three times, confirming the factory settings of all programmable functions of menu No. 1

Menu #2 [Button (I+IV)-]

Resetting all programmable functions of Menu No. 2 to factory defaults

To reset the programmable features to factory defaults, two steps are required.

  1. Entering programming mode. Press buttons I+IV simultaneously for 2 sec. The siren will sound one short beep and the alarm will flash once, confirming the success of STEP 1
  2. Briefly press button III on the key fob three times. Each press will be confirmed by a short siren tone and an alarm flash. After some time, three siren sounds will sound, the alarm will flash three times, confirming the factory settings of all programmable menu No. 2 functions.

Feedback in the alarm system allows the owner to quickly receive information about the car when intruders commit any illegal actions. Read about how to install a Sherkhan alarm in a car.

Consider a real situation: your car has sensors installed all over the area, and someone hit the fender of the car badly. The result of this incident will be an instant message to the keychain. If it also has an LCD display, you will see what part of the car is affected.

Important! A simple alarm without feedback would simply turn on the siren.

However, the feedback properties are not limited to this. The most advanced models constantly exchange messages between the controller on the key fob and the control unit in the car. The result is that any code grabber is useless in such a situation.

Naturally, most Sherkhan alarm models have feedback. Due to the increased activity of car thieves, developers have to come up with more and more new ways of protection.

Separately, you need to talk about the autorun system present in the Sherkhan alarms. It allows you to warm up the engine before you get behind the wheel. While at home with a cup of tea, you can instruct the car to autostart and even turn on the air conditioner.

Alarm Sherkhan Magikar

This series is one of the most popular on the market, now the 14th model is gaining popularity, but SCHER-KHAN MAGICAR 10 still holds the palm of spectator sympathy. At one time it was a real breakthrough in the world of alarms. Even now, this Sherkhan alarm system has an impressive list of features, here are the main ones:

  1. Slave mode - allows you to control the Sherkhan alarm from a distance.
  2. Ability to control two cars with one key fob.
  3. Tachometer sensor.
  4. Possibility to connect additional sensors.
  5. Improved energy saving.
  6. Parking timer.
  7. Possibility of blocking buttons.
  8. Alarm.

Of course, this is not a complete list of the possibilities that the Sherkhan signaling can give. One of its main advantages is its low price.. Also, one cannot ignore such a function as connecting to the CAN bus.

An adapter is built into the processor unit. It allows you to quickly and without any difficulties install the Sherkhan alarm. Modern technical solutions greatly simplify the installation process. Therefore, every driver can install an anti-theft system. True, for this you will have to spend at least a day.

As a result, it is possible to install the Sherkhan alarm even in the most difficult places of the car. Not surprisingly, it is extremely difficult for car thieves to cope with the detection of this brand's anti-theft system. With the right installation, finding the right wires will take so much time that any intruder will simply run away.

If we talk about other technical characteristics of the Sherkhan alarm, then the range of the transmitter cannot be ignored - it is as much as 2 kilometers. In addition, a reliable encryption system is implemented here, which guarantees the stability of the signal within the city.

Attention! The coding algorithm varies from signal to signal. As a result, intellectual hacking is useless.

With each new version of the Sherkhan alarm system, the Magikar series receive new features that allow you to control the anti-theft system with great convenience. The tenth version of the key fob has such functions as:

  • Displays the status of the sensors installed on the machine.
  • Two channels of information transmission - one to remove the protective mode, the other to turn it on.
  • Commands are confirmed by sound and visual signals.
  • There is a vibration mode.
  • Screen backlight.
  • Determining the temperature inside the cabin.
  • The key fob also shows the status of the vehicle's battery and accumulator.

Of course, this list of functions cannot be called impressive, but it is more than enough to ensure that the car is properly protected. Much more interesting opportunities for the driver are provided by the processor unit, more precisely, it is he who is the brain of the car. The device is capable of performing functions such as:

The shock sensors included are two-level and are considered one of the most sensitive in their series. But in order for them to be able to adequately recognize the danger, it is necessary to configure them.

Alarm setting Sherkhan Magikar 10

It all starts with programming the CAN module, perhaps this is the most important stage of work. First, determine the firmware number. This information is located on the end of the central block. If you want the climate system to work together with the Sherkhan alarm, connect CN11 to the orange wire of the car network.

Attention! Some machines do not have the ability to connect to the CAN port. To remove this limitation, you will need a repair cable.

A special role in setting up the Sherkhan alarm is played by programming functions. Let's start by setting the settings for automatically closing the windows when switching to armed mode. To do this, you need to reprogram function 2-4 to position 3. After you do this, you no longer have to think about whether you closed all windows before setting the protective mode.

Be sure to take a few minutes and set the windows to close automatically. According to statistics, most car thieves use this oversight of drivers to get inside.

There are also a number of other important functions with which you can start programming the Sherkhan alarm:

  1. To activate SLAVE mode, set function 2-14 to 2.
  2. To disable the return to armed mode, you will need to set f1-8 to position 3. This will allow you to forget about the constant return of the system to the protected mode after disabling.
  3. Ф 1-1 transfer to position 3. This will avoid triggering the Sherkhan alarm when you open the trunk with a command from the key fob even when the security mode is on.
  4. An important advantage of the Sherkhan alarm system is that it can be trained. Therefore, one of the first actions that you must take is to start the engine at idle. In this case, you need to hold the VALET button for about two seconds. The hazard warning light should turn on and off. After that, you need to release the key, wait 5 seconds, and press it again for 4 seconds. One siren signal will announce the successful completion.

Of course, there are a number of other important points in the instructions, but it is these points that will help you use the purchased device with maximum comfort.

Operation of the alarm system Sherkhan Magikar 10

Let's start with the simplest, namely arming the car, for this you will need to perform the following actions:

  1. Turn off the engine and close all doors, including the trunk, hood, and so on.
  2. Find the button with number 1 on the key fob, click on it. After that, the door locks should be locked. This activates the starter lock.
  3. If the installation is successful, the siren will sound, the alarm lamp will flash, the headlights will flash, the key fob will respond.

The sensors will turn on 30 seconds after the mode is activated.

Alarm Sherkhan Logicar

The Sherkhan company produces many alarms of different specifications. At the same time, she is famous for two well-known series: "Magicar" and "Logicar". There is also a UNIVERSE series, but it is not yet so popular in the domestic market.

A series of car alarms "Magikar" from the company "Sherkhan" currently has 14 models. The Logicar lineup is more modest. There are only 6 full-fledged products and two special editions. The latest and most technically advanced is the Logicar 6i alarm. Nevertheless, the most popular version is the one in the abbreviation of which there is a unit, which will be discussed further.

The Logicar 1 alarm system from the Sherkhan company has similar technical properties with the Magikar 10 device. But there are, of course, some differences. For example, the radius of the transmitter is one and a half kilometers.

The loss of 500 meters affected the price, you can buy the Sherkhan Logicar 1 alarm for 5,000 rubles. The AES-128 encryption system is used to protect the signal. This makes the system immune to intellectual hacking.

The display has a high contrast, thanks to which you can easily track all the processes that occur with the car. Additionally, this device from the Sherkhan company is able to display the following parameters:

  • engine temperature,
  • battery charge,
  • the time the engine has been running during automatic start.

The Sherkhan alarm keychain has an ultraviolet coating and is not afraid of scratches. High-strength plastic avoids cracks and chips even when dropped. There are four function keys for control. Programming can be carried out directly from the key fob.

By carrying out each command, the driver will receive audiovisual confirmation. There is also a function to control two cars at once. It is worth saying that this Sherkhan alarm, despite its low cost, has a number of significant advantages, including:

  • personal code,
  • disabling protection in two steps,
  • Turbo mode and JackStop,
  • work with petrol and diesel engines,
  • installation both on cars with automatic transmission and manual transmission.

You can set the automatic start time for the Sherkhan alarm. It will automatically run every few hours. But for this to become possible, this function must be activated once every 24 hours.

If we talk about the rules of operation, then they are similar to the Magikar 10 alarm. It is worth noting that all Sherkhan alarms have a similar tuning algorithm. Except for some technical nuances. If we talk about the rules of operation, then they are almost the same.

Results

The Sherkhan company has been producing multifunctional alarms at an affordable price for many years. For 5-7 thousand, you can purchase a system that will be equipped with autorun and feedback. Installation is carried out both independently and in a service center.

When operating security alarm systems from one manufacturer, it is noticeable that the activation algorithms for individual functions are similar for different models. This statement is confirmed by the Sherkhan signaling. Models differ in functionality, but at the same time they have common settings algorithms.

Functionality of the security system

Security systems are widely used due to the use of a secure radio channel with a long transmission distance - up to 2000 meters. Information is exchanged between the processor unit and the key fob switch. The Sherkhan car alarm works successfully on cars with automatic transmission or “mechanics”, in a 12 V circuit. The system has the following levels of protection:

  • processor - IP-40, which provides for installation in the car;
  • siren - IP-65 with installation in the engine compartment away from heated surfaces.

Before using the Scher khan Magicar complex, you should read the instructions in order to study the basic functionality.

Functionality of key fobs


The control elements include a multifunctional block with 4 control buttons and the ability to control operating modes and the status of alarms and auto systems.

Among the main functions of the controls, the following positions of magicar stand out:

  1. Interception protection system code signals.
  2. Synchronization of readings of all control key fobs involved in the work.
  3. The presence of two control channels.
  4. Low battery indication and a power save function.
  5. Battery level monitoring.
  6. Programming of all functions from the control key fob.
  7. Talkback level indication.
  8. Car interior temperature control.
  9. Engine timer indication when working with autorun or Turbo mode.
  10. Other auxiliary functions(current time, parking timer).

The key fob automatically reminds the owner of certain events, which is accompanied by vibration, sound or visual indication

Processor operating functions


The processor unit for providing work has extended functionality. At the same time, it is convenient to present the main features in the combined groups:

  1. Car security mode. Assumes manual or automatic statement for protection. When choosing the option of how to turn off the alarm, direct deactivation or gradual deactivation using a personal identification code is allowed.
  2. Engine guard with running engine. This mode is used when the car is warming up, when it is left for a short time.
  3. Autorun mode allows you to give commands to start at certain time intervals, or based on the specified parameters (temperature in the cabin or cooling system).
  4. Programming individual parameters. The mode allows you to set the alarm operation conditions for certain conditions and situations.
  5. Special modes of use. Anticipate unusual situations.

The security complex Sher khan magicar allows you to set the necessary alerts for the owner of the car, regarding the state of protection, the operating parameters of the car and the alarm.

Technical features


Before use, it is important to know some of the technical features of Sherhan. Alarm signals are transmitted as the following signals:

  • siren operation (beep, sounds continuously, 30 sec.);
  • visual signal(works through an alarm, sounds intermittently at a frequency of 1 Hz for 30 seconds);
  • radio signal (works through a dedicated channel, the sound is intermittent at a frequency of 0.08 Hz for 40 seconds).

To protect electrical circuits from damage, including with directional action, some equipment protection measures are provided:

  • delayed action fuses with automatic operation;
  • internal protection transistors;
  • directional diodes email current (when changing polarity);
  • current-burning resistors;
  • surge protection electric current.

The alarm system operates under the conditions of ensuring the following physical parameters:

  1. Temperature Range: from - 40 °С to + 85 °С.
  2. Equipment supply voltage: 9-18 V.
  3. Current consumption: 20-35 mA.

The power supply of the alarm control units, according to the operating instructions, is provided by:

  • working unit - 12 V from the battery;
  • key fob switch– 1.5 V via a standard AAA battery;
  • key fob- 6 V through batteries with the index CR-2025.

For the normal use of the signaling capabilities, one should not only know the purpose of the individual Magikar keys in accordance with the manual, but also establish the order of their activation.

How to use key fobs


To master the activation of modes, the conventional designation of the keys of the remote control is used:

  • key I - a symbol of a closed lock;
  • key II - a symbol of an open lock;
  • button III - a symbol of an open trunk;
  • button IV - question mark.

When activating the modes, short (0.5 sec.) and long (about 2 sec.) pressing of the control keys are used. Below, a long press is represented with the symbol "-". Popular buttons and their combinations:

  • key I (activation of protection, termination of the alarm, blocking the start, search for a car);
  • key II (disarming, opening doors, duplicating other commands of button I);
  • key III (display activation);
  • key IV (checking the state of the security complex);
  • I "-" (activation of the "Panic" mode, forced engine stop);
  • II "-" (interception of an ignition attempt - Pit-Stop mode);
  • III "-" (opening only the trunk);
  • I + III (activation of the Valet mode);
  • I+IV (enable/disable shock sensor);
  • II + IV (activation / deactivation of the self-start timer);
  • II + III "-" (using the "Hands free" mode);
  • III+IV "-" (setting a personal identification code);
  • I + IV "-" (activation of the programming mode).

The active use of possible modes increases the efficiency of the Scher Khan car alarm, increases the degree of car security.

Basic operating modes


The task of the required mode is carried out from the programming menu also using the key fob. Please note that the current time task allows you to use the autostart timer, parking timer. As an example, the order of programming the following modes can be given:

  1. Programming. The transition is carried out by a combination of buttons I + III "-". Confirmation of entry through the indication "Pro 9".
  2. Time setting. In programming mode, the transition is automatic. The time indicators flash, use the I and II keys to set the current time.
  3. Autorun mode. Called by the IV key. “Timer” flashes, use the I and II keys to set the autorun time.
  4. Owner's call. Activated with the IV button. The handset symbol appears on the screen. Enable/disable the function by pressing the I key.
  5. Exit programming. Becomes available after pressing the IV key. A tone signal confirms the exit.

It should be remembered that the time of using the active function does not exceed 15 seconds. In the passive state, the transition to the normal mode is carried out.

Some additional features


The Scher-khan Magicar security system, by analogy with the Logicar, has some additional functions:

  1. Parking timer. It is activated by double short pressing of button III.
  2. Turning off the siren. During the night period, a short simultaneous pressing of the I+II keys activates the function.
  3. Valet mode. Provides door opening without starting the engine. It starts working after a joint short press of the I + III buttons in the disarmed mode.
  4. Forced one-time remote start of the motor. It is carried out by long pressing the II key. This activates the protection mode.

By analogy with Starline B9, the alarm uses a second communication channel. This is required when installing optional equipment. It can be a hood lock, preheater. In this case, they are controlled via the second radio channel. If the function is programmed, it is activated by long pressing the IV key.

Possible failures in work


Among the possible incorrect manifestations of signaling in operation, both damage to the structure and individual elements, and individual failures in the execution of commands are distinguished.

If the algorithm “how to turn on” the armed mode is completely executed, and there is no display on the switch, the possible reasons may be the following:

  • disruption of radio signal transmission;
  • damage to the antenna or key fob as a result of impact;
  • violation of the basic settings of the transmitting device;
  • battery discharge.

In this case, it will be necessary to carry out diagnostics in accordance with the installation map, and step by step check all the indicated positions. In some cases, different alarm schemes do not differ depending on the equipment used. So, Starline alarm installation cards are close in execution.

Performed repairs will require the installation of basic settings again, and individual features will have to be programmed.

Among other failures, according to reviews, the work notes:

  • independent transition to the Valet mode;
  • difficulties with disabling the security mode;
  • continuous notification of individual indicators - for example, a blue light is constantly on:
  • there is no reliable engine start remotely.

Before you go to the repair of key fobs, it is worth working out a plan "b". Very often, the cause of failures is a discharged battery, or the basic flip key of the car.

Violation of sensors is usually associated with damage to the electrical power circuit, which is easily diagnosed by a broken wire.

GOST R 41.97-99 (Uniform provisions concerning the approval of vehicle alarm systems (VTS) and motor vehicles with regard to their alarm systems (VTS))

GOST R 50009-2000 (Electromagnetic compatibility of technical equipment. Security alarm equipment. Requirements and test methods)

Thank you for purchasing the SCHER-KHAN MAGICAR V two-way car security system.

The constant research and development of our company embodies the most advanced ideas and serves to satisfy all the needs of users of our systems.

Car alarm SHERKHAN MagiKar 5 is a complex electronic equipment of a car. The safety of your life, health and road conditions, the quality of work of nearby radio-electronic equipment and communication facilities depend on its functioning and proper installation. Trust the installation of the system only to specialized service stations. During operation, periodically check the correct functioning of the system.

PLEASE READ CAREFULLY!

ATTENTION!
When buying, check that the warranty card is filled out correctly.
The manufacturer and supplier of the system is not responsible for any ignorance of the instructions for installation and operation, as well as for errors made during installation.
If you encounter any problems related to the functioning of the system, please immediately contact the service center for diagnostics or advice.

The installation of the SCHER-KHAN MagiKar-5 car alarm must be carried out by qualified specialists. A car alarm is a complex technical device that involves connection to the electrical circuits of a car related to the operation of the engine.

If an icon appears on the key fob display warning that the key fob battery is low, take measures in advance to replace the battery. We recommend that you store a new spare battery in the vehicle, keeping its original packaging.

PURPOSE

Car alarm SCHERKHAN MAGICAR V is a car alarm with the ability to control over the radio using a key fob-communicator with a liquid crystal display. The system exchanges information between the key fob-communicator and the processor unit at a distance of up to 1500 m. SHERKHAN MagiCar 5 has a function for automatically starting the engine by commands from the key fob or by commands from the internal timer. The SCHER-KHAN MAGICAR V system is designed to work on gasoline or diesel vehicles with a fuel injection system and an on-board network voltage of 12V. The protection of the processor unit, shock sensor, call sensor, antenna unit is made according to the standard and provides for installation in the car. The siren is made according to and can be installed in the engine compartment, away from the exhaust manifold and high voltage systems.

Contents of delivery

When buying a system, make sure that the delivery is complete. The specified set of delivery is basic and can be supplemented in accordance with the wishes of the buyer with additional components.

Instruction manual 1
Installation Guide 1
Processing unit SCHER-KHAN MAGICAR V 1
Keychain communicator 1
Shock sensor with cable CN5 1
Vehicle call sensor with CN6 cable 1
Antenna unit 1
LED indicator (LED) 1
Temperature sensor 1
Interlock relay with block 1
Siren 1
Hood/trunk limit switch 1
6-pin power connector with cable and fuse CN1 1
6 pin power connector with cable CN2 1
9 pin control connector CN3 1
4-wire connection cable for antenna unit CN7 1
2 pin auxiliary channel control connector CN8 1
Car call sensor sticker 1
Sticker for antenna unit 1
Glass sticker 2

Additional components SCHER-KHAN MAGICAR

SCHER-KHAN BP-2 immobilizer bypass module
Keychain communicator SCHER-KHAN MAGICAR V (with display)*
Keychain SCHER-KHAN MAGICAR V (without display)*
* The processor unit can only remember the codes of three key fobs.

Keychain communicator functions

  • Multifunctional, 4-button LCD keychain communicator
  • Protection against interception of MAGIC CODE code packets
  • Audiovisual confirmation of executed commands
  • Vibrating bell
  • Loud beeps
  • Ultra long distance communication up to 1500 m with processor unit
  • Automatic display backlight
  • Low battery indication
  • Vehicle battery voltage indication
  • Indication of temperature in the passenger compartment
  • Current time indication
  • Indication of engine operating time in automatic mode
  • Remote engine start
  • Programming the engine start time (accurate to the minute)
  • Sound and visual alert reminder mode
  • Operational, from the key fob, programming of all system functions
  • Economy Power (one AAA element)
.

Processing unit functions

  • Automatic engine start for vehicles with automatic or manual transmission
  • Operation of the starting system with both petrol and diesel engines
  • Operation of the starting system with engines having a turbine
  • Starting the engine on command from the key fob
  • Automatic engine start every 2 hours
  • Automatic engine start at a pre-set time every 24 hours
  • Monitoring the engine start by signals from the generator or by noise in the on-board network
  • Personal code for access to the car interior if the key is lost
  • Power output for controlling the car's central locking
  • Trunk release power output
  • Alarm control power output (two circuits)
  • Programming the lock relay type
  • Auto arming (programmable function)
  • Sound warning before automatic arming
  • Automatic return to armed mode if the door was not opened
  • Sound warning before automatic return to armed mode
  • Armed mode without siren signals
  • Two universal programmable control channels for additional devices
  • Ability to connect negative and positive door sensors
  • Input for negative trunk sensor
  • Locking and unlocking the door locks when starting and stopping the engine
  • Possibility of arming with and without confirmation siren signals
  • Open Door Alarm Warning (Programmable)
  • Panic or JackStop mode
  • Highly sensitive two-level shock sensor with sensitivity adjustment
  • "Hands free" function for automatic arming / disarming when the owner moves away / approaches the car
  • Dual mode hands-free function
  • Parking lights not switched off warning

TECHNICAL SPECIFICATIONS

Alarm types:
Influence on the main and additional electrical equipment of the car
STSTS controls the power supply to: Maximum current per channel
Starter or ignition interlock circuit Imax = 0.2 A
Port Alarm Circuit Imax = 10 A
Starboard Alarm Circuit Imax = 10 A
Ignition circuit Current Imax = 30 A
Accessory chain Current Imax = 30 A
Starter circuit Current Imax = 30 A
Ignition circuit 2 Current Imax = 0.2 A
Additional siren Current Imax = 2 A
Relay for unlocking electric door locks or unlocking the standard system of the Central locking (CL) of the car Current Imax = up to 15 A
Relay for controlling the locking of electric door locks or locking the standard system of the Central lock (CL) of the car Current Imax = up to 15 A
Power trunk lock relay Current Imax = 10 A
Auxiliary device control channel 1 Current Imax = 0.2 A
Option control channel 2 Current Imax = 0.2 A
The channel for disarming the STSTS standardly installed on the car Current Imax = 0.2 A
Control methods
  • Remotely with a radio frequency transmitter (key fob) at a frequency of 433.92 MHz ± 0.2% with a power of not more than 10 mW
  • From the ignition key
  • Automatically based on signals from sensors
Electrical circuit protection

Fuses. (Automotive slow-acting fuses according to wiring diagram)

Spheres of protection
Other parameters

Batteries

* The table shows the average value. The service life of the key fob battery depends on the intensity of use of the key fob and the quality of the battery, the key fob operating modes.

..

ATTENTION!

Use only quality batteries. The use of a poor quality battery can lead not only to a reduction in the life of the key fob, but also to its damage.

KEYFOB-COMMUNICATOR SCHER-KHAN MagiKar-5

Preparing the Keychain Communicator for Operation

Before using the key fob, you must bring it into working condition, because. during transportation and storage, an insulating gasket is installed between the contact of the battery and the contact plate of the key fob, which prevents the battery from discharging before operation. Before using the key fob, remove it. To do this, release the battery cover lock, press the cover and slide it in the direction opposite to the antenna. Remove the battery. Remove the insulating pad between the battery and the collector plate. Install the battery back, observing the polarity indicated on the bottom of the battery compartment. If there is no indication of the polarity of the battery, then it is set with a negative terminal towards the antenna. Close the battery cover. Keyring is ready to go.

Symbols on the keyfob-communicator display
Timer start indicator
TURBO mode indicator
Passive arming indicator
Hands-free mode indicator
Siren indicator
Shock sensor off indicator
Vibrating alert indicator
Indicator of turning on the automatic control of the central lock by ignition
Door open indicator
Trunk/hood open indicator
Shock sensor alarm indicator (optional sensor)
Car owner call indicator
Engine running indicator
Ignition on indicator in security mode, indicator of side lights not switched off
Key fob transmitter operation indicator
Battery discharge indicator of key fob-communicator
VALET mode indicator
Locking and unlocking indicator. Security Mode Status Indicator
Clock indicator, car battery voltage, interior temperature, engine warm-up time during automatic start
Purpose of the buttons on the key fob-communicator

Example notation:

I - quick (0.5 sec.) button press
I- - long (2 sec.) button press
(I + II) - fast (0.5 sec.) simultaneous pressing of the buttons (combination of buttons)
(I + II) - - long (2 sec.) simultaneous pressing of the buttons (combination of buttons)

Control channel number Button number Press duration Executed function (mode)
1 I 0.5 sec.
  • Enable / disable security mode
  • Enable/disable call mode
  • Stop alarm mode
  • Enable/disable starter/ignition interlock
2 I-(1) 2 sec. Activate "Hands Free" function first operating mode (symbol does not flash)
3 I-(2) 2 sec. Activate the "Hands free" function of the second operating mode (the symbol flashes)
4 I-(3) 2 sec. Deactivate hands-free function (symbol is off)
5 (III+IV) - 2 sec. Recording and playback of a fragment on the voice module (Option)
6 II 0.5 sec. Additional channel control 1
7 III 0.5 sec. Additional channel control 2
8 IV 0.5 sec. Checking System Status
9 II- 2 sec. Starting and stopping the engine from the key fob
10 III- 2 sec. open trunk
11 IV- 2 sec. "Panic". To stop, press the I button
12 (I+II) 0.5 sec. Siren on/off
13 (I+III) 0.5 sec. "Valet" mode enable/disable
14 (I+IV) 0.5 sec. Automatic control of the central lock by ignition on / off
15 (II+III) 0.5 sec. Automatic arming enable/disable
16 (II+IV) 0.5 sec. Timer start enable/disable
17 (III+IV) 0.5 sec. Turbo mode enable/disable
18 (I+III)- 2 sec. Shock sensor enable/disable
19 (I+II)- 2 sec. Enter programming menu 1
20 (I+IV)- 2 sec. Enter programming menu 2

Note:

With a long 2 sec. pressing the I button, the modes change sequentially in the order (1) > (2) > (3) > (1) … . In mode (2) the "Hands-free - "function has a high working range - the symbol flashes.

Setting the time on the keychain communicator display

Setting the current time is required before starting the operation of the system or when changing the key fob battery. Follow the steps according to the table below.

Execution steps Press duration Executed function (mode)
STEP 1 (II+III)- 2 sec.
STEP 2 I 0.5 sec. Turn on the current time setting mode. The indications of the current time are flashing, confirmed by the sound signal of the key fob
STEP 3 I 0.5 sec. Changing the value of the clock
II 0.5 sec. Changing the minutes
STEP 4 (II+III)- 2 sec.

ATTENTION!

Setting the exact time is a prerequisite for the correct operation of the automatic engine start by timer.

Setting the keyfob communicator, vibration call, owner call, temperature display standard "°F" or "°C"

To set the desired key fob operation mode, follow the steps in accordance with the table below.

Note: STEP 2 must be completed within 15 seconds. after STEP 1.

Arming [Button (I)]

Close doors, hood, trunk. Briefly press button I on the key fob. The system will switch to the armed mode, the door locks will be locked, the starter (ignition) interlock will turn on until the system is disarmed.


When arming:

Enable sensors:

  • Immediately after the LED starts flashing, the system begins to monitor the status of the doors, hood, trunk, call sensor of the owner of the car.
  • The shock sensor will turn on after 30 seconds. after arming.
  • Note:

    If, when arming, you heard three key fob signals, and on the display for 5 seconds. the image of an open door or trunk flashes, this means that the door, hood / trunk is open in the car. The door, hood/trunk sensor will be immediately armed when its functionality is restored.

    The hood area is not displayed separately, the hood sensor must be connected to the trunk sensor wire.

    Disarming [Button (I)]

    When the system is armed, briefly press button I on the key fob. The SHER-KHAN MagiKar-5 alarm system will be disarmed, the door locks will be unlocked, the starter (ignition) blocking will be disabled.


    When disarming:
    ...

    HANDS FREE function [Button (I)-]

    ATTENTION!

    The "Hands free" mode works only when using a communicator keyfob with a liquid crystal display; when using optional keyfobs without a display, this mode is not available.

    When you press button I on the key fob-communicator for 2 seconds. You can turn Hands Free on or off. When the "Hands-free" function is enabled, the system will automatically arm itself when you are 15-35 m away from the car with the key fob-communicator*. or is removed from the security mode and unlocks the door locks when approached. The function has two modes of operation:

    In the first mode, the mark on the display does not blink and the range of the function is minimal.

    In the second mode, the mark on the display with the inscription "AUTO" flashes and the range is maximum.

    The change of operating modes takes a long 2 seconds. by pressing the I button in the following order: (Function on, mode 1) > (Function on, mode 2) > (Function off) > (Function on, mode 1)….

    Arming/disarming will be accompanied by a melodious signal from the key fob-communicator.

    Continuous use of the "Hands-free" function is not recommended, as its use drastically reduces the battery life of the remote control.

    * Note:

    The distance from the unit to the communicator key fob, at which the system makes a decision to arm or disarm, may vary and depends on a number of objective reasons: the relative position of the communicator key fob and antenna unit antennas, the presence of metal objects near the antennas, radio interference on the air, weather etc. …

    When the hands-free function is enabled:

    The mode change is accompanied by one signal from the key fob-communicator.

    When the HANDS FREE function is turned off:
    ....

    Starting the engine on command from the key fob [Button (II) -]

    To start the engine, press button II on the remote control for 2 seconds. The system will be armed, the door locks will be locked, the car engine will start. After the engine has started, the key fob-communicator displays information about the time remaining until the end of the engine operation in automatic mode. Engine run time is programmable and can be 15/25/45/5 minutes (programmable function 2-4). To start driving. You need to open the door, insert the ignition key into the lock and turn it to the "ON" position. To do this, you have 20 seconds, after this time the system will transfer control to the ignition switch, if you do not turn on the ignition, the engine will be stopped.

    If the launch did not occur the first time, the system will try again. The system makes no more than three attempts to start, after which it goes into standby mode. If the car engine does not start after the last attempt, contact a service station to diagnose your car.

    At the time of launch:

    SCHERKHAN MAGICAR V car alarm will not start the engine if:

    • Ignition on
    • The car engine is already running
    • Door or hood/trunk open
    • Backup mode failed for vehicles with manual transmission

    On successful launch:

    Note: If the car's engine is started automatically, the current time indicator shows the time remaining until the engine is stopped. Time is displayed in countdown mode. Time display format in this mode: [ XX min: XX sec.]

    When the engine stops automatically:

    Trunk opening [Button (III)-]

    Press and hold for 2 sec. button III of the key fob, after which the trunk will open. If the system is armed (doors locked), it will disarm, the doors will unlock, and the starter will be disabled. To implement this function, it is necessary to have a trunk lock solenoid connected to the corresponding output of the main unit of the system.


    When opening the trunk:

    Checking System Status [Button (IV)]

    If you need to check the status of the system, briefly press button IV on the communicator. Information about the state of the system will be shown on the display of the key fob communicator, as well as confirmed by siren and alarm signals.

    When checking system status:

    When checking the status of the system, the current time indicator shows the temperature value in the car interior. The temperature can be displayed in either °F or °C.

    The temperature inside the car is 10°C.


    Repeated short pressing of the button IV of the keyfob-communicator within 6 seconds after the first one allows you to view information about the car battery voltage in volts.

    The voltage on the car battery is 13.9V.


    Panic or JackStop mode (anti-seizure) [Button (IV)-]

    When you press the button IV of the remote control for 2 seconds. The system will enter the "Panic" mode or JackStop mode (protection against capture) - programmable function 1-4.. If the system was disarmed, it will arm itself, the door locks will be locked. The siren will sound for 90 seconds, the alarm will flash for 90 seconds. The "Panic" mode stops the automatic engine start mode. After 90 sec. the system will go into armed mode until it is disarmed by the key fob or emergency shutdown mode. Panic mode can be stopped by briefly pressing button I. Panic and JackStop modes are used in case of danger or when it is necessary to draw attention to the vehicle.

    When activating the "Panic" and JackStop modes:
    Differences in the "Panic" and JackStop algorithms (depending on the selected value of the programmable function 1-4):

    ATTENTION!

    JackStop mode should only be used in emergency situations. It is not a regular constantly used CCTTC mode. it provides for stopping the engine while driving.

    When choosing one or another mode, consult with a specialist.

    Siren Silence [Button (I+II)]

    By briefly simultaneously pressing the buttons I + II of the key fob, you can turn on or turn off the siren signals. In this case, the key fob signals and alarm signals will work as usual. Siren activation is indicated by the presence of a symbol on the key fob display.


    When the siren is turned on:
    When turning off the siren signals:

    VALET mode [Button (I+III)]

    To disable the security functions of the system and when transferring the machine to a service station for maintenance, you can use the VALET mode. To do this, briefly press the I + III buttons on the remote control.

    In VALET mode, you can control the locking and unlocking of the door locks. To lock or unlock the locks, briefly press button I.

    The VALET mode is shown on the display with the symbol

    To exit the VALET mode, briefly press the buttons I + III of the key fob

    When VALET mode is enabled:
    When turning off VALET mode:
    .....

    Disabling the two-level shock sensor [Button (I+III)]

    You can disable the two-level shock sensor. Simultaneously press and hold for 2 seconds. buttons I + III of the remote control, as a result, the sensors will be turned on or off. The indication of the sensor disconnection is the symbol on the key fob display. Switching off the sensor is necessary if you leave the car where false alarms are possible (the car is parked near tram tracks, a child or an animal remains in the car).

    When the shock sensor is disabled:
    When the shock sensor is turned on:

    The shock sensor is called two-level, because it has two levels of response from the impact on the car.

    In case of a weak impact, the system warns with 4 short siren sounds and 4 alarm flashes. Key fob - communicator gives a short tone signal, the symbol of impact on the car flashes on the display. If the impact is strong, the system goes into alarm mode for 30 seconds.

    Central locking control for turning the ignition on and off [Button (I + IV)]

    By briefly simultaneously pressing the buttons I + IV of the key fob, you can turn on or turn off the automatic control of the central lock (CL) by turning the ignition on and off. If the function is enabled, the door locks will be automatically locked after 30 seconds. after the engine is started and all doors, the hood/trunk will be closed. The locks are unlocked immediately when the ignition is switched off. The function is indicated by the presence of a symbol on the key fob display.


    When the central locking control function from ignition is turned on:
    When the central locking control function is turned off from the ignition:

    Passive arming [Button (II+III)]

    The passive setting function can be turned on / off by briefly pressing the P + W buttons on the key fob. When passive arming is enabled, the system will automatically arm itself after 30 seconds. after closing the last door or after disarming with the key fob. The SHER-KHAN MagiKar-5 alarm system warns of passive arming with alarm signals and (or) siren every 10 seconds. If within 30 sec. doors (hood/trunk) were opened, the system will arm itself in 30 seconds. after closing the doors (hood/trunk).


    When passive arming is enabled:
    When turning off passive arming:
    ......

    Setting the timer for automatic engine start [Button (II+IV)]

    Briefly press buttons II + IV of the key fob to turn the engine start on or off by timer. The indication of the inclusion of starting the engine by timer is the presence of the label "TIMER" on the key fob display. The system provides two modes of starting the engine by timer. The first mode allows you to start the engine every day at a predetermined time, the second mode allows you to start the engine periodically, every 2 hours to warm up (or cool the interior in countries with a hot climate). Two modes cannot be used at the same time, the mode you need can be selected by programmable function 2-3 .


    To automatically start the engine by timer at the right time (24 hours), it is necessary to make a reservation for this mode. For this:

  • Select start time (see table)
  • Press the buttons II + IV and turn off the label "TIMER"
  • Execution steps Button number or combination of buttons Press duration Executed function (mode)
    STEP 1 (II+III)- 2 sec. Entering the key fob function programming mode. The appearance of the symbol is confirmed by the beep of the key fob
    STEP 2 II 0.5 sec. Turn on the timer setting mode. The readings of the previously set time are flashing, confirmed by the sound signal of the key fob
    SHAGZ I 0.5 sec. Changing the value of the clock
    II 0.5 sec. Changing the minutes
    STEP 4 (II+III)- 2 sec. Exit the key fob function programming mode. Confirmed by beep

    In order to turn on or off the engine start by timer every 2 hours, briefly press the buttons II + IV of the key fob. Setting the start time in this mode is not required, the first engine start will occur 2 hours after the mode is turned on.

    When the timer engine start is enabled:
    When turning off the engine start by timer:

    Note: Automatic start of the engine by timer every 24 hours is useful for starting the engine every day at a certain time if your car is parked outside the range of the key fob.

    ATTENTION!

    The engine start time according to the 24 hour timer can be shifted up to ±2 minutes per day.

    TURBO Mode [Button (II+IV)]

    If the car has a Turbo-engine, then after a long operation at high speeds it is not recommended to stop it immediately. The engine should idle for some time to cool the turbine. For this, the SCHER-KHAN MAGICAR V system has a TURBO mode (turbo timer). If the TURBO mode is on, then at the end of the trip the engine will run for 2 minutes. To turn the TURBO mode on or off, briefly press the buttons III + IV of the remote control.


    When TURBO mode is enabled:
    When turning off the TURBO mode:

    To activate the mode at the end of the trip, do the following:

  • Put the gear lever in neutral or "P" position.
  • Turn the ignition key from the ON position to the OFF position. The engine will continue to run after this for another 2 minutes.
  • Get out of the car, close the doors. As soon as the doors are closed, the alarm will flash
  • Now you can arm the system. The engine will then run until the expiration of 2 minutes. interval. When the car is armed, the door, hood/trunk sensors, the driver call sensor are immediately armed, and the shock sensor will start working after the engine stops. The engine will be immediately stopped when the door, hood/trunk sensor is triggered, and the system will go into alarm mode. If necessary, you can urgently stop the engine by pressing for 2 seconds. keychain button II.

    Auxiliary channel 1 control [Button (II)]

    If your car is equipped with an electromechanical hood lock, an additional preheater or other service equipment, you can control the operation of these devices using a key fob. To do this, briefly press button II on the remote control. A short or long signal will appear at the output of additional channel 1 of the processor unit (programmable function 2-5). The siren and parking lights signals will differ when controlling an additional channel, depending on the state of the programmable function 2-5. If a channel is programmed to beep continuously (Programmable Function Value 4 2-5), the system will confirm its activation and deactivation with siren and alarm signals. If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel. The additional channel does not work in the VALET mode and in the alarm mode.

    Note: If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel (programmable function 2-5)

    Auxiliary channel 2 control [Button (III)]

    If your car is equipped with an electromechanical hood lock, an additional preheater or other service equipment, you can control the operation of these devices using a key fob. To do this, briefly press button III on the remote control. A short or long signal will appear at the output of additional channel 2 of the processor unit (programmable function 2-6). The siren and parking lights signals will differ when controlling an additional channel, depending on the state of the programmable function 2-6. If a channel is programmed for a long beep (Programmable Function Value 4 2-6), the system will confirm its activation and deactivation with siren and alarm signals. If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel. The additional channel does not work in the VALET mode and in the alarm mode.

    Turning on an additional channel:
    Turning off the additional channel:

    Note: If a short signal is programmed at the output of an additional channel, the system will only confirm the inclusion of the channel (programmable function 2-6)

    Alarm mode

    If the door, hood/trunk is opened in armed mode, the system will go into alarm mode for 30 seconds, alarms and sirens will last 30 seconds. At the end of 30 sec. the system will return to armed mode. If the shock sensor alarm zone is triggered (strong impact), the system will go into alarm mode for 15 seconds, the alarm and siren signals will last 15 seconds. At the end of 15 sec. the system will return to armed mode. When the warning zone of the shock sensor is triggered (weak impact), the system will not go into alarm mode, but will only issue a series of four short signals by a siren and an alarm. You can stop the alarm mode by short pressing the button I on the key fob. The locks will not be unlocked, and the system will switch from alarm mode to armed mode.

    In alarm mode:

    Reminder mode

    If the communicator keyfob received an alarm signal on the door, hood/trunk, shock sensor, call sensor and you did not notice it immediately, then the keyfob, after transmitting the alarm signal, goes into reminder mode (short beeps and indication of the zone that caused the alarm mode) . To stop the reminder mode and check the state of the car, briefly press the key fob button IV or button I to exit the security mode and unlock the door locks.

    In reminder mode:

    Note: Keyfob communicator does not go into reminder mode when receiving a warning signal from a shock sensor (weak impact)

    Car Owner Call

    If you need to call the owner of the car, tap with a hard object (coin, keys, etc.) near the call sensor. The call sensor LED will flash green. The function of calling the owner of the car is available immediately after arming. To stop the signals of the key fob-communicator, press the button I of the key fob. To stop the signals from the key fob-communicator and check the condition of the car, briefly press the IV button.


    When calling the car owner:

    Access to the car without a key fob

    Access to a car without a key fob may be required in a number of cases. For example, if the key fob is lost, if the battery in the key fob has run out, if you are relaxing on the beach and do not want to take the key fob with you (the key fob and keys are closed in the car). The SCHERKHAN MAGICAR V system provides such an opportunity. To ensure that only you are allowed access, the system uses a personal code consisting of four digits. The value of each digit of the code can vary from 1 to 9. Thus, the code can have a value from 1111 to 9999. The code is entered and recorded through the call sensor of the car owner.

    Recording a personal code:

    In order for you to use this function, you must enter your code into the system memory. To do this, follow several steps:

  • Turn on the ignition
  • open the door
  • While the LED is flashing, tap the call sensor the number of times corresponding to the first digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the second digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the third digit of the code. After 1.5 sec. the LED will confirm the selected number with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the fourth digit of the code. After 1.5 sec. The LED will confirm the selected number with red flashes.
  • You will hear one siren tone to confirm that the code has been programmed, and the alarm will flash once.
  • If you made a mistake on any of the steps, then you need to record the code, starting from point 1.

    Entering a personal code:
  • Tap the call sensor 10 times. Each time the LED in the sensor will flash green. The time between blows must be less than 1.5 seconds.
  • The LED will quickly flash red to confirm that the previous step has been completed. If the LED does not flash red, then start from step 1 again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the first digit of the code. After 1.5 sec. the LED will confirm the entry of the first digit with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the second digit of the code. After 1.5 sec. the LED will confirm the entry of the second digit with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the third digit of the code. After 1.5 sec. the LED will confirm the entry of the third digit with red flashes and start flashing again.
  • While the LED is flashing, tap the call sensor the number of times corresponding to the fourth digit of the code. After 1.5 sec. the LED will confirm the entry of the fourth digit with red flashes.
  • If the code is entered correctly, the system will disarm, the door locks will open, and the key fob-communicator will receive a signal to disarm the system. If the code is entered incorrectly, then the key fob will receive a call signal from the owner, and it will be necessary to repeat all the steps starting from step 1.
  • The system allows five attempts to enter the code within 30 minutes. If the code was entered incorrectly, then its entry is blocked for 24 hours or until you disarm the system using the key fob.

    Battery protection (out-of-dimension warning)

    The SHER-KHAN MagiKar-5 alarm helps protect the car battery from discharge. If you forgot to turn off the parking lights, then when arming, the key fob-communicator will give a series of beeps for 5 seconds. At this time, the images of the lock and side lights will flash on the display. The warning tone will repeat every 30 seconds. three times.

    Starter or ignition lock

    The system in armed mode will not allow you to start the car engine. When you try to start the engine in armed mode, the system will send an alarm signal to the key fob communicator. An alarm about turning on the ignition will be displayed by flashing side lights on the key fob communicator, sound and vibration signal. The engine blocking operation mode is selected when the system is installed at a service station and depends on the values ​​of two programmable functions 1-4 and 1-8. You can find out more about blocking the engine of your car at the place where the system is installed. When the starter interlock is selected, the system will prevent the vehicle's starter from restarting if the engine is started in automatic mode.

    Open door warning

    Car alarm SCHERKHAN MAGICAR V warns of an open door (programmable function 1-2). When a custom function value is selected, the alarm flashes if the car door is open.

    Protection of the radio channel from code interception

    The system has special protection for the commands transmitted by the key fob. Each time you press a button on the system's key fob, the code message changes according to a special algorithm. This is done to protect the system from interception of the code and its selection (intelligent hacking of the security system). The code protection algorithm is specially designed for the SCHER-KHAN MAGICAR system and is unique, not applicable in one security system of other brands.

    Motor protection in automatic start mode

    The system in automatic start mode constantly monitors the operation of the engine. If the engine stops before the end of the warm-up cycle (engine failure or out of fuel), then no later than 20 seconds. the processor unit of the system will turn off the ignition. Repeated automatic start of the engine will not be possible until the malfunction is eliminated. For vehicles with a manual transmission, you must perform the backup mode again.

    Shock sensor sensitivity adjustment

    You can adjust the sensitivity of the shock sensor depending on your requirements. A regulator is provided to adjust the sensitivity of the sensor. Turning the knob clockwise increases the sensitivity, and counterclockwise decreases it until the sensor turns off. Consult a service station about the location of the shock sensor, it must be easily accessible for adjustment.

    Adjusting the sensitivity of the owner's call sensor

    You can adjust the sensitivity of the car owner's call sensor depending on your requirements. To adjust the sensitivity on the sensor, a step regulator with three positions is provided. The extreme left position of the regulator corresponds to the minimum sensitivity of the sensor, the extreme right - to the maximum. The sensor should be located in the lower corner of the car's windshield.

    Adjusting the volume of siren confirmation signals

    You can adjust the volume of the siren's short beeps. To reduce the volume, you need to cut the loop from the wire on the siren's body. The system can be equipped with any siren according to the wishes of the owner, including those where there is no possibility of adjustment.

    Backup mode (only for manual transmission)

    The standby mode excludes the possibility of automatic starting of the engine if the manual transmission lever is not set to the neutral position. Depending on your requirements, you can choose one of three redundancy algorithms (programmable function 1-6).

    Algorithm 1
    Algorithm 2

    To perform a backup (prepare the vehicle for the subsequent automatic start of the engine), do the following:

  • At the end of the trip, without turning off the engine, place the gear lever in neutral position
  • Close the hood/trunk doors
  • Remove the key from the ignition switch (in the OFF position). The engine will keep running
  • Open the door and get out of the car. Close the door. The engine will stall.
  • Opening the door after completing the fifth step will make it impossible to automatically start the engine. Diagnosis of the reasons for its failure is described below.

    If at least one step from the above algorithm is not performed, then there will be no backup mode and automatic engine start will not occur. In this algorithm, redundancy will be prohibited if the door, hood / trunk are open at the time the ignition is turned off.

    Algorithm 3

    To perform a backup (prepare the vehicle for the subsequent automatic start of the engine), do the following:

  • At the end of the trip, without turning off the engine, place the gear lever in neutral position
  • Close the hood/trunk doors
  • Press for 2 sec. keychain button II
  • Remove the key from the ignition switch (in the OFF position). The engine will keep running
  • Open the door and get out of the car. Close the door. Engine will stall
  • Opening the door after completing the fifth step will make it impossible to automatically start the engine. Diagnosis of the reasons for its failure is described below.

    If at least one step from the above algorithm is not performed, then there will be no backup mode and automatic engine start will not occur. In this algorithm, the implementation of the reservation requires you to each time press button II on the key fob before turning off the ignition (by turning the key in the ignition switch to the OFF position).

    ATTENTION!

    Close the sunroof and windows before leaving the vehicle. Do not leave people or animals in the vehicle when the reservation mode is being executed.

    Do not start the engine automatically if there are people or animals in the car.

    Leave the gear lever always in the neutral position. Do not use automatic engine start on open top vehicles.

    If the operation of the redundancy mode differs from the described algorithms or does not occur, urgently contact a service station for advice. Until the causes of malfunction are eliminated, do not use automatic engine start.

    PROGRAMMING NEW KEYFOBS

    The system can remember the codes of three key fobs. To program new key fobs, follow two steps.

  • Turn the ignition key three times from OFF to ON. The alarm will flash once to confirm entry into programming mode.
  • Not later than 4 sec. after the flash of the alarm, press the button I of the key fob, the code of which must be entered into the memory of the processor unit.
  • To exit the programming mode, do not take any action for 4 seconds. after writing the code of the last key fob.

    If no action is taken after step 1, then after 4 seconds. the alarm will flash 2 times, the system will switch from the key fob programming mode to the VALET mode.

    Note:

    The SHER-KHAN MagiKar-5 alarm system has three memory cells for storing key fob codes. When you try to write the fourth key fob, the code of the first recorded key fob will be deleted.

    PROGRAMMING FUNCTIONS USING THE KEYFOB

    Programming the functions of the CTCTS using the key fob consists of four steps.

  • Entering the programming mode and selecting the programming menu. To enter Menu No. 1, press the I + II buttons simultaneously for 2 seconds. To enter Menu No. 2, press the I + IV buttons simultaneously for 2 seconds. The siren will sound one short beep and the alarm will flash once, confirming the successful completion of STEP 1.
  • Press the IV button to select the Menu function you want to change. The number of presses must correspond to the number of the selected function. For example, to select function 4, you need to briefly press the button IV of the key fob four times. Each button press will be confirmed by a short siren tone (if enabled) and an alarm flash.
  • Wait a few seconds. The system will confirm the number of the selected function to be changed with short siren sounds and alarm flashes. The number of signals will correspond to the number of the selected function.

    Note:

    If, when choosing a function, you made a mistake with the number of clicks and (or) there are no siren and alarm signals, then you must repeat all the steps starting from STEP 1.

  • Press the I button to select the factory setting for the function. To confirm this, the siren will give one short signal, the alarm will flash once. Press the II, III, or IV button to select optional function values. To confirm this, the siren will give two, three or four short beeps, the alarm will flash two, three or four times.
  • Note:

    If you hear one long siren signal, this means the system has exited the function programming mode. To continue programming, repeat all steps from STEP 1.

    ATTENTION!

    If you need to change more than one function from the Menu you have selected, then the selection of each function to change must begin with STEP 1.

    Menu of programmable functions
    Menu #1 [Button (I+II)-]
    No. p / p. Function [Button (I)] Factory setting [Button (II)] [Button (III)]
    1-1 Delay before the starter rotates after the ignition is turned on. Should be increased for a diesel vehicle. 4 sec. 10 sec.
    1-2 Open door warning Not There is
    1-3 The duration of the control pulse of the central lock. Should be increased for pneumatic central locking system 0.8 sec. 4 sec.
    1-4 "Panic" or JackStop mode (protection against robbery) "Panic" (Starter lockout) JackStop (ignition lock)
    1-5 Central locking control for turning the ignition on and off Turned off Turned off
    1-6 Launch reservation method. (Only for manual transmission) Automatically, every time the ignition is turned off Automatically, whenever the ignition is turned off, but provided that the doors are closed Only manual mode, before switching off the ignition for reservation, it is necessary to press button II for 2 seconds.
    1-7 Starter rotation time Standard Standard + Minimum Standard + maximum

    Note on function 1-4: This function allows you to select the "Panic" mode or the JackStop mode (protection against robbery):

    Resetting all programmable functions of Menu No. 1 to factory defaults
  • Entering programming mode. Press buttons I+II simultaneously for 2 sec. The siren will sound one short beep and the alarm will flash once, confirming the success of STEP 1
  • Briefly press button III on the keyfob three times. Each press will be confirmed by a short siren tone and an alarm flash. After some time, three siren sounds will sound, the alarm will flash three times, confirming the factory settings of all menu 1 programmable functions.
  • Menu #2 [Button (I+IV)-]
    Resetting all programmable functions of Menu No. 2 to factory defaults

    To reset the programmable features to factory defaults, two steps are required.

  • Entering programming mode. Press buttons I+IV simultaneously for 2 sec. The siren will sound one short beep and the alarm will flash once, confirming the success of STEP 1
  • Briefly press button III on the keyfob three times. Each press will be confirmed by a short siren tone and an alarm flash. After some time after this, three siren sounds will sound, the alarm will flash three times, confirming the factory settings of all programmable menu #2 functions.