Physiotherapy matrix. Why ALT "Matrix" is the best series of laser therapeutic devices? Basic control units for "matrix" devices

The "Matrix" devices (as well as the devices of the previous generation of the series) consist of four main parts:

To create a working set of the Matrix apparatus, it is absolutely not necessary to purchase all four components of the apparatus - it is enough to have a base unit and one or more emitting heads. If necessary, you can always additionally purchase the necessary equipment.

The base blocks of the Matrix apparatus, depending on the version, have 2 or 4 channels for connecting radiating heads with the possibility of independently setting parameters (radiation frequency and power) for each channel. The presence of independent channels allows you to increase the efficiency of work, since for the implementation of various methods it is not necessary to change the emitters, it is enough to select the desired channel by simply pressing a button.

Each apparatus "Matrix" contains a built-in photometer, which allows you to measure the radiation power of all types of heads. When measuring the radiation power, the device automatically determines the type of head used, the radiation wavelength and displays the value of the radiation power in watts (for impulse heads) or in milliwatts (for continuous heads) on a digital display.

The Matrix device provides for the possibility of external radiation modulation, including the BIO mode, which changes the laser radiation power during the procedure synchronously with the patient's pulse and breathing rate.

The device is equipped with various interchangeable laser and LED emitting heads (see page Emitting heads). In addition, specialized heads are connected to the device:

  • infrared matrix (ML01K), which has a large radiation area (0.89 microns, maximum power 50-60 W);
  • multi-color matrix laser-LED head MLS-1 "EFFECT", combining pulsed lasers with a wavelength of 0.63 and 0.89 microns and LEDs of blue, green and IR ranges;
  • radiating heads for extremely high frequency (EHF) therapy with a wavelength of 7.1, 5.6 and 4.9 mm.

If necessary, the heads of the EHF range are equipped with nozzles for acupuncture.

All of the above radiating heads (with the exception of the heads of the EHF range) also work with devices of the Mustang-2000 series.

Various, mirror, acupuncture and intracavitary nozzles can be used with heads.

Specifications

Radiation modes

Pulse, continuous, modulated

Number of emission channels
ALT "Matrix" 2-channel
ALT "Matrix" 4-channel
Radiation wavelength, µm

Determined by the type of replaceable external emitter

Method of setting the pulse repetition rate, Hz
Fixed "quick selection" pulse repetition rates, Hz

10, 80, 600, 3000

Frequency setting range "arbitrary selection"
Duration of laser pulses, ns
Choosing an exposure time

Fixed or arbitrary

Fixed values ​​of "quick selection" exposure time, min
Setting range of exposure time "arbitrary selection"

1 s - 90 min

Range of controlled pulse radiation power, W
Range of controlled average radiation power, mW
Power supply
voltage, V
frequency Hz
Maximum power consumption, VA
Operating temperature range, °С
Overall dimensions, mm

275 x 196 x 105

340 x 240 x 140

Weight, kg
ALT "Mustang-2000" 2-channel
ALT "Mustang-2000" 4-channel

Laser and LED emitting heads for ALT "Matrix"

All of the emitting heads listed below (with the exception of the heads of the EHF range) also work with devices of the Mustang-2000 series.

Laser emitting heads for ALT "Matrix"

Radiant type
heads

Working mode

Optical range

Wavelength,
micron

Radiation power, W,
at least

Pulse, modulated

IR + red

7W(0.89) +15mW(0.63)

Pulse

Pulse

Pulse

Pulse

Pulse

Pulse

Continuous, modulated

Continuous, modulated

Continuous, modulated

Continuous, modulated

Continuous, modulated

Continuous, modulated

Continuous, modulated

LED emitting heads for ALT "Matrix"

Matrix emitters

Radiant type
heads

Working mode

Optical range

Wavelength,
micron

Radiation power, W,
at least

Pulse

60 W (10 laser diodes)

MLS-1 "Effect"

Pulse and modulated

5 W (imp.)

3 W (imp.)

Intravenous blood irradiation

KL-VLOK-M

Intravenous blood irradiation

To work with a flexible light guide

The choice of radiating heads (number and technical parameters) is mainly influenced by economic and methodological considerations. We recommend choosing the minimum reasonable set of emitting heads, which is enough to implement the basic techniques. In the future, it will always be possible to additionally purchase the missing emitting heads, guided by the principles below.

  1. LO7 and KLO6, with the maximum power for LT, are used mainly for the treatment of diseases of the tonic type, when it is necessary to provide the maximum dose.
  2. Of the LO1-LO4 radiant heads, LO3 is recommended, although the methodological recommendations most often indicate lower powers (5-10 W), a reasonable margin does not hurt, and when working with nozzles, the power decreases by an average of 2 times. Let's not forget that for the implementation of many techniques, 2 radiating heads are needed - a paravertebral technique, impact on joints from two sides, etc.
  3. The pulse radiating head LOK2, operating in the red spectral range (0.63-0.65 μm), is most effective in combined or combined exposure with the head LO3 (IR spectrum).
  4. KLO1 and KLO7 with their minimum power are used almost exclusively in reflexology.
  5. Of the continuous heads, the KLO3 is the most common, which, according to its characteristics, completely replaces helium-neon lasers in terms of method.
  6. Matrix head ML01K is the most versatile and should be included in almost every kit.
  7. The emitting head MLS-1 "EFFECT" is difficult in its application and has a high cost, which is often justified. In many ways, the efficiency of the head is determined by the presence of pulsed lasers, both red and IR ranges.
  8. CL-ILBI for intravenous laser blood irradiation is rarely included in a universal set, since it is preferable to have a separate device (see below).
  9. Matrix LED emitting heads МСО3-МСО6 are used practically only in dermatology and cosmetology.

Thus, the most optimal today is the presence of 4 emitting heads in the kit:

  • pulse IR with a power of at least 15 W (LO3) - 2 pcs.
  • matrix with pulsed IR lasers (ML01K) - 1 pc.
  • continuous with a radiation wavelength of 0.63 microns and a power of 10 mW (KLO3) - 1 pc.

The heads must be equipped with magnetic (ZM-50 and MM-50) and mirror (ZN-35 and ZN-50) nozzles, and depending on the field of application, optical nozzles can also be added - ENT, dental, gynecological, etc. n. To conduct ILBI, a room with certain sanitary and hygienic requirements is required, therefore it is preferable to use a separate device (ALT "Matrix-ILBI").

Optical attachments

A wide range of intracavitary attachments are produced for Matrix laser therapy devices, which allow you to increase the effect of laser therapy by delivering radiation directly to the pathology focus.
In various attachments, radiation losses are low and range from 20 to 60% of the power at the emitter output, which characterizes their high quality.

Proctological tips

Forms a radiation spot O 5-10 mm at an angle of 120°, which makes it possible to obtain a local power density distribution.
Used in urology for transrectal irradiation of the prostate


It is used in urology for irradiation of the prostate gland (transrectally) or in proctology for irradiation of the walls of the rectum.

Distributes the radiation evenly over the cylinder O 9mm and length 25mm.
It is used in proctology for irradiating the walls of the rectum (anal fissures, hemorrhoids, etc.).

Urological handpiece

It is made of flexible materials 30 cm long. At the end it has a dissipating cylindrical area 20 mm long.
Designed for transurethral effects on the prostate gland and urethra.

Gynecological tips

Scatters radiation over an area of ​​O15 - 20 mm in contact.
Used for intravaginal irradiation of the cervix and appendages.

It is used intravaginally for some inflammatory diseases.

Otorhinolaryngological tips

Set of 3 nozzles.
When connected, an adapter is used.

Dental tips

Set of 3 nozzles.
When connecting, a collet clamp is used.

Acupuncture nozzles

Designed for reflexotherapeutic effects on BAP
Attachment for emitters of EHF-therapy, designed to influence BAP

Emitting heads with a single laser source allow the use of optical attachments for introducing laser radiation directly into the light channel without the use of special optics, using a simple threaded or collet connection (“hard” tool). At the exit of the nozzles, the necessary distribution of the light flux delivered to the right place is obtained.

For laser therapy, a set of tools containing the following indicatrices is sufficient: “cone”, “wide cone”, “cone to the side”, “sphere”, “cylinder”. The necessary scattering diagrams, depending on the task, are formed by processing the distal end of the light guide to a certain geometric shape, introducing a metal reflector into the cavity of the protective shell of the distal end of the metal reflector.

The light guide tool consists of three main parts: a connector for fastening, a rod and a working part - an optical scattering element. From the optical connector to the diffuser, the radiation passes through the light guide. The diffuser provides convenience of fixation in the cavity of the pathological focus and its uniform irradiation.

Mirror and magnetic nozzles

Mirror and magnetic nozzles are connected to the devices of the Matrix series, which serve to enhance the effect of laser therapy during the treatment process.

Mirror attachments receive radiation that is not absorbed by the patient's skin (reflected from it) and reflect it back, thereby significantly reducing losses and increasing the amount of radiation absorbed by the patient.

Magnetic nozzles are designed for the combined effect of a magnet and a laser - magneto-laser therapy. The combined use of these effects is much more effective than their separate use. In medical practice, magnets of 25, 50 and 75 mT are most often used. The magnetic field of the nozzles is maximally elongated towards the area of ​​influence.

Magnetic nozzles have different values ​​of magnetic induction and are designed for magnetic laser therapy (MLT). In medical practice, magnets with an induction of 25, 50 and 75 mT are most often used, for which an optimal set of KM-2 nozzles for MLT has been developed. The magnets currently used are made of special alloys of rare earth metals based on Nd2Fe12B, and are designed in such a way that the magnetic field is maximally elongated in the direction of impact. One set contains two magnet holders and two ring magnets (Fig. 7), which have different values ​​of magnetic induction from different sides: 25 and 50 mT; 50 and 75 mT, respectively. This is done in order to be able to vary them as freely as possible and apply a magnet on two radiating heads at the same time. The most commonly used mirror magnet is 50 mT - ZM-50.

For matrix emitters ML01K for ALT "Matrix" specially designed magnetic attachments MM50 and MM100 are used, with a magnetic induction of 50 and 100 mT, respectively.

In addition to intracavitary and magnetic, there are optical nozzles for external use.

Mirror nozzles: ZN-35 (diameter 35 mm) and ZN-50 (diameter 50 mm) are the most common. Are intended for a mirror-contact way of influence. They are extremely versatile and useful:

  • increase the depth and intensity of the therapeutic effect,
  • ensure the stability and reproducibility of the procedure,
  • protect medical staff from reflected radiation,
  • ensure the hygiene of the procedure,
  • make it easier to calculate the dose, since the effective area of ​​exposure is assumed to be 1 cm2.

Acupuncture nozzles: plastic A-2 (spot size no more than 2.5 mm) and modern light guide with a metal tip A-3 (spot size no more than 1 mm) - designed to concentrate laser radiation on acupuncture points.

Prefix "BIO" to ALT "Matrix"

Biosynchronization of time parameters of laser radiation exposure with endogenous biorhythms of a particular patient is one of the most interesting and promising directions in the development of technology and treatment methodology. This mode of operation was implemented in the ALT "Mustang-2000" with the block-attachment "BIO", and now it is also applied in the "Matrix" apparatus. The "Matrix-BIO" block allows for laser irradiation modulated by signals from pulse and respiration sensors connected to the patient. Biocontrolled laser therapy takes into account the biorhythmological characteristics of the patient, thereby achieving a stable therapeutic effect, the absence of side effects at a lower dose of exposure.
When a pulse sensor is connected, the amplitude of laser radiation is modulated by the patient's pulse, when a breath sensor is connected, accordingly, by the patient's breathing. As a result, in the phases of exhalation and diastole, the radiation power is minimal, and in the phases of inspiration and systole (the most favorable moment of exposure) it reaches the maximum value set before the procedure.
The principle of measuring pulse parameters is based on the operation of an optoelectronic pair photodiode-LED. Depending on the amount of blood filling, which changes synchronously with the pulse, the intensity of the signal passed through the finger changes, which is recorded by a photodiode. The processed signal is fed further to the laser power modulation circuit.
The breathing sensor is a pair of thermistors (in a plastic case) that change their resistance in proportion to the change in air temperature that occurs during breathing; located directly at the nose of the patient.

MATRIX laser therapy devices consist of the following main parts:

  • Basic control unit;
  • Remote emitters (radiating heads);
  • Optical, magnetic and mirror nozzles.

Basic control units of MATRIX devices:

Basic blocks ALT "MATRIX" are designed to set and control radiation parameters.
External emitters (radiating heads) are connected to the base units - laser, LED, matrix, for intravenous blood irradiation (ILBI) and EHF-therapy.
The base blocks of the MATRIX laser therapy device, depending on the version, have 2 or 4 channels for connecting radiant heads with the possibility of independent setting of parameters (frequency, radiation power and exposure time) for each channel.

Prices of basic blocks ALT "MATRIX":

Emitting heads for ALT "MATRIX":

.

Laser emitting heads:

Type µm range Mode Power Price
LO IR 0.89
Red 0.63
impulse,
continuous
7 W
15mW
3 300 rub.
LO1 IR 0.89 Pulse 5 W 3 000 rub.
LO2 IR 0.89 Pulse 9 W 4 100 rub.
LO3 IR 0.89 Pulse 15 W 5 300 rub.
LO4 IR 0.89 Pulse 20 W 7 100 rub.
LO7 IR 0.89 Pulse 80 W 11 400 rub.
LOK2 Red 0.63-0.65 Pulse 5 W 9 700 rub.
KLO1 Red 0.63 Continuous 5 mW 3 500 rub.
KLO2 Red 0.65-0.67 Continuous 30 mW 6 500 rub.
KLO3 Red 0.63 Continuous 10 mW 6 500 rub.
KLO4 Red 0.63 Continuous 30 mW 18 000 rub.
KLO5 Red 0.83 Continuous 40 mW 6 400 rub.
KLO6 Red 0.83 Continuous 200 mW 7 400 rub.
KLO7 IR 1.3 Continuous 5 mW 3 000 rub.

LED emitting heads:

Matrix emitters:

Type µm range Mode Power Price
MLO1K IR 0.89 Pulse 60 W 6 450 rub.
ML01KR Red 0.63-0.65 µm Pulse 30 W RUB 21,350
MLS-1 "Effect" IR 0.89 Pulse 5 W RUB 19,350
IR 0.88 Continuous 50 mW
Red 0.63 Pulse 3 W
Green 0.53 Continuous 3 mW
Blue 0.47 Continuous 20 mW

Radiating heads of the EHF range:

Laser emitting heads:

Type Wave length, mm Mode Power
mW / cm 2
Price
LO-KVCh-4.9 4,9 Continuous 4-12 11 900 rub.
LO-KVCh-5.6 5,6 Continuous 4-12 11 900 rub.
LO-KVCh-7.1 7,1 Continuous 4-12 11 900 rub.

Optical nozzles for ALT "MATRIX":

MATRIX laser therapy devices have a wide range of optical intracavitary and external attachments that allow radiation to be delivered directly to the pathology zone.

UROLOGY:

Nozzle P-1. Designed for irradiation
prostate rectally.
Price 900 rubles.
Nozzle U-1. Has soft silicone
tip. Designed for transurethral
effects on the prostate and urethra.
Price 900 rubles.

PROCTOLOGY:

Nozzle P-2. It is used to irradiate the walls of a straight line
intestines.
Price 900 rubles.
Nozzle P-3. It is used to irradiate the walls of a straight line
intestines.
Price 900 rubles.

GYNECOLOGY:

Nozzle G-1. Used to irradiate the cervix and
appendages.
Price 900 rubles.
Nozzle G-2. Used to irradiate the cervix and
appendages.
Price 900 rubles.
Nozzle G-3. Used for wall irradiation
vagina
Price 900 rubles.
L1. Set of nozzles ENT. Price 1200 rub. C1. Set of nozzles for dentistry. Price 1200 rub.

Magnetic and mirror nozzles for ALT "MATRIX":

TYPE Purpose Price
KM-2 Set of magnetic nozzles 25,50,75 mT 750 rub.
ZM-25 Mirror magnet 25 mT 400 rub.
ZM-50 Mirror magnet 50 mT 650 rub.
MM-50 Magnetic attachment for ML01K 50 mT 650 rub.
MM-100 Magnetic attachment for ML01K 100 mT 880 rub.
ZN-35 Mirror nozzle 35 mm 180 rub.
ZN-50 Mirror nozzle 50 mm 180 rub.
A-2 Acupuncture nozzle 270 rub.
A-3 Acupuncture nozzle 350 rub.

Additional accessories for ALT "MATRIX":

Literature on laser therapy:

Name Price
Moskvin S.V., Buylin V.A. Fundamentals of laser therapy. 256 p. 500 rub.
Geinits A.V., Moskvin S.V., Azizov G.A. Intravenous laser blood irradiation. 144 p. 100 rub.
Moskvin S.V., Gorbani N.A. Laser-vacuum massage. 72 p. 100 rub.
Moskvin S.V. Laser therapy in dermatology: vitiligo. 124 p. 100 rub.
Moskvin S.V., Myslovich L.V. Combined laser therapy in cosmetology 5 000 rub.
Moskvin S.V. and etc. Laser therapy for diseases of the urogenital area 200 rub.
Nasedkin A.A., Moskvin S.V. Laser therapy of patients with heroin addiction. 48 p. 100 rub.
Moskvin S.V., Kupeev V.G. Laser chromo- and color therapy 95 p. 100 rub.
Moskvin S.V. The effectiveness of laser therapy. 256 p. 100 rub.
Brekhov E.I., Buylin V.A., Moskvin S.V. Theory and practice of EHF-laser therapy.160 p. 200 rub.
Moskvin S.V. and etc. Therapy with matrix pulsed lasers of the red radiation spectrum. 116 p. 100 rub.
Amirkhanyan A.N., Moskvin S.V. Laser therapy in dentistry. 72 p. 100 rub.
Mufaged M.L. and etc. Laser therapy in urology. 132 p. 200 rub.

When used, Matrix laser devices affect not only a specific organ or area of ​​the body, but also the general condition of the body. Therefore, it cannot be said that their effect affects only that part of the body to which their radiation is directed. No matter what disease or injury a person treats with a laser, this device also improves their immunity and improves their general condition.

In this section, we will consider specific diseases and suboptimal conditions that the device helps to cope with. And in some cases, the use of this device is enough to cope with painful conditions without resorting to drugs.

Matrix laser devices are beneficial when they are used in the following areas of medicine:

  • Surgery
  • sports medicine
  • Cosmetology
  • Dermatology
  • Urology
  • Proctology
  • Gynecology
  • Dentistry
  • Gastroenterology
  • Cardiology
  • Neurology
  • Pulmonology
  • ENT diseases

Lasers are also successfully used in the treatment of pets: cats, dogs, hamsters and others.

Below we will consider in detail each section of medicine where Matrix laser devices can be successfully used:

Matrix in surgery

Indications for use: bone fractures, wounds, burns, frostbite, purulent diseases, diseases of the veins and arteries, heel spurs, trophic ulcers, hematomas, bruises, etc.

Application result: The use of the Matrix apparatus during treatment significantly reduces the recovery time. In fractures, callus forms faster. In the treatment of wounds, burns and frostbite, the result in the form of swelling, pain and redness can be observed after the second procedure. By increasing blood circulation in the extremities, the Matrix apparatus, when used, restores diseased veins and arteries. As a result, chilliness of the limbs and pain when walking are reduced. The Matrix apparatus, by activating the nutrition of the skin, allows you to accelerate the healing of purulent diseases and ulcers.

Matrix in sports medicine

Indications for use: sports injuries: bruises, injuries of the musculoskeletal system, dislocations of the joints, sprains. Fatigue after intense workouts. Preparing an athlete for competition.

Application result: When treating sports injuries with the Matrix apparatus, the recovery time for an athlete is reduced from one and a half to two times. Reduces the likelihood of recurrence of injuries. The use of the device relieves fatigue, stimulates the body's strength, enhances metabolism. As a result, the state of the athlete before the competition is activated.

Matrix in cosmetology

Indications for use: Withering of the skin, the formation of wrinkles, the appearance of edema and cellulite.

Application result: The use of the device preserves youth and elasticity of the skin, prevents the formation of wrinkles, stops the development of cellulite. When using the Matrix apparatus in the tissues of the body, exchange and recovery processes are improved, which allows you to restore the structure of the skin and tissues, and slow down the process of their aging. Also, the laser device enhances and prolongs the effect of the use of cosmetics.

Matrix in dermatology

Indications for use: Herpes, dermatitis, dermatosis, acne, eczema, neurodermatitis.

Application result: If you start using the Matrix device for herpes at an early stage of the disease, this allows you to stop its development. Treatment with the device with an already developed disease contributes to faster healing of ulcers. The use of the device in dermatitis, dermatosis, eczema, rashes and neurodermatitis accelerates the healing of damaged areas. Also, the use of Matrix helps to achieve a long-term remission of these diseases.

Matrix in urology

Indications for use: Prostatitis, prostate adenoma, cystitis, urethritis, nephritis, pyelonephritis.

Application result: Due to its anti-inflammatory properties, the Matrix laser device, when used, significantly speeds up the process of treating patients with urological diseases. The device also helps to normalize the functions of the prostate gland in case of prostatitis, and alleviates symptoms during exacerbations of diseases. The use of the device in the treatment of urological diseases can significantly reduce the amount of drugs consumed. In order to reduce the likelihood of exacerbations of chronic diseases, you need to use the device once every two to three months.

Matrix in proctology

Indications for use: Hemorrhoids, anal itching, fissures, paraproctitis.

Application result: If you start using the Matrix laser device at an early stage of the disease, this will help to avoid surgical intervention. Also, the device will help in restoring the state of the body in the postoperative period.

Matrix in gynecology

Indications for use: Birth and postpartum complications, inflammation of the appendages, inflammation of the uterus, mastitis, erosion, climate syndrome.

Application result: Due to its ability to cope with various inflammations, the Matrix device helps very well with inflammation of the appendages and uterus. Also, the use of the device contributes to the cure of other gynecological diseases.

Matrix in dentistry

Indications for use: Pulpitis, caries, periodontitis, paradontosis, ulcers of the oral mucosa.

Application result: As a result of laser treatment, areas of teeth with reduced mineralization are restored. The pain syndrome is reduced. Inflammatory phenomena disappear after 3-5 sessions of using the device. The mucous membrane recovers much faster.

Matrix in gastroenterology

Indications for use: Gastric ulcer, duodenal ulcer, gastritis, cholecystitis, hepatitis, pancreatitis, colitis.

Application result: Using the Matrix laser device, patients with gastric and duodenal ulcers after several procedures experience relief, reduction of pain. As a result of the subsequent examination, patients show a decrease in inflammation and rapid healing of ulcers. The Matrix apparatus reduces inflammation of the gallbladder and liver, and also stimulates the process of liver regeneration and normalizes its function.

Matrix in cardiology

Indications for use: Hypertension, myocardial infarction, coronary heart disease, angina pectoris.

Application result: The Matrix laser device stabilizes blood circulation and heart activity, increases the electrical stability of the myocardium. Also, the device helps to reduce cholesterol levels in the blood and improves blood microcirculation. If a person has an artificial heart valve, an implanted pacemaker or a pacemaker, this will be a contraindication for using the device.

Matrix in neurology

Indications for use: Diseases of the joints and spine, arthritis, bursitis, arthrosis, osteochondrosis, sciatica, neuralgia.

Application result: Pretty soon after the start of using the device, an analgesic effect appears. When using the device, the tissues of the body begin to feed better, blood circulation improves, inflammation is removed, and the affected area recovers more quickly. Increased mobility in the joints. The process of formation of intervertebral hernias is suspended. The best results can be achieved if the treatment with the device is combined with massage and physiotherapy exercises.

Matrix in pulmonology

Indications for use: Bronchitis, bronchial asthma, pneumonia.

Application result: In the treatment of pulmonary diseases, the Milta apparatus helps to achieve a positive result due to its anti-inflammatory, antimicrobial and analgesic effect. Using the device for bronchitis allows the patient to feel much better after the third procedure. Use in the treatment of bronchial asthma reduces symptoms requiring inhalation. In the treatment of pneumonia, the use of the device in combination with other methods reduces the recovery time by five to seven days.

Matrix in ENT diseases

Indications for use: Rhinitis, pharyngitis, otitis media, tracheitis, sinusitis, sinusitis, tonsillitis, prevention of influenza and SARS.

Application result: When treating ENT diseases with the Matrix laser device, the patient's condition improves much faster than without its use. With otitis media, the pain goes away after the third or fourth procedure. It also reduces the amount of discharge from the ear. Rhinitis, pharyngitis, tracheitis, sinusitis, sinusitis and tonsillitis are also well cured by the Matrix apparatus. After a course of procedures with the Matrix device, a lasting improvement occurs.

Contraindications to the use of Matrix devices

Malignant neoplasms of any localization, benign tumors with a tendency to progress, systemic blood diseases, leukemia, pregnancy at all stages, benign tumors of the female genital organs, acute infectious diseases, severe forms of diabetes mellitus and thyroid diseases, severe forms of diseases of the cardiovascular system ( crisis course of hypertension, cardiovascular insufficiency of the third stage), the presence in a person of an artificial heart valve, an implanted pacemaker or a pacemaker. Acute disorders of cerebral circulation, lung diseases with the phenomenon of pulmonary insufficiency of the third stage, liver and kidney failure in the stage of decompensation, fever (fever) of unknown origin, increased skin sensitivity to light (photodermatitis and photodermatosis), lupus erythematosus, mental illness in the acute stage .

Message to visitors to our site

Ladies and gentlemen! In order for you to decide with confidence whether the Matrix laser device will help you in the treatment of your ailments, we have a free consultation with a doctor for you. Our doctor has extensive experience in treating patients with Matrix devices. The doctor will answer all your questions regarding the use of the device in the treatment of diseases. The doctor will help you choose the device that is right for the treatment of your ailment. He will also advise you on the treatment of your disease.

In order to contact our doctor for a free consultation, call our phones.

Expansion of the range of laser devices

We have expanded the range of offered laser devices.