Scheme of connecting the boiler with liquid fuel kiturami. High efficiency and simple structure is the Kiturami diesel boiler. Reasons for no ignition - error code "01"

Diesel boiler Kiturami Turbo-13 R

The leader series of liquid fuel boilers Kiturami TURBO is an example of economical and efficient heating on liquid fuel. Reliable and lightweight, the Kiturami TURBO-13R boiler is perfect for heating a house in a country house, cottage up to 150 m2. The boiler operates in automatic mode and has a number of pleasant features for its owner.

The fuel for the liquid fuel boiler Kiturami Turbo 13R is diesel fuel heating kerosene and diesel fuel GOST-305.

Turbocyclone burner

The turbocyclone burner built into the Kiturami TURBO boiler is the latest world-class technology, which distinguishes each such boiler from analogues. It is thanks to her that Kiturami Turbo has the greatest efficiency, economy and reliability.

Boiler operation

For quick and high-quality heating of hot water, the boiler heat exchanger is installed in the "hottest" part of the boiler.

Kiturami TURBO is a boiler with low noise levels - up to 55 dB. This pleasant characteristic is realized thanks to the special structure of the turbulator, created on the principle of a car muffler.

High quality is the hallmark of the TURBO series. Boilers are made of durable stainless steel, which extends the service life of such equipment by +10 years.

Along with excellent efficiency indicators, Kiturami TURBO has a pleasant compact size that allows you to place the boiler on an area of ​​1 sq.m.

Automation and security

The boiler works according to the settings of the CTX-1500 control unit. Automation includes:

Indication "Temperature of the heat carrier in the heat exchanger" (Options: less than +60°С, +60°С and more, +85°С (max))

Circulation pump (indication)

Burner (indication)

Network (display)

Switch

The Turbo boiler can be controlled remotely. For this, a remote room temperature controller CTR-5900 is used. The list of possibilities that this thermostat opens up includes:

Room function

Sleep function

Bath function

Away function

Function "Programming"

Time programming (regulator)

Setting the heating water t

Hot water t check

T°С indoors (indicator)

t controller in the room

The model has the latest computerized self-diagnosis for the organization of complete safety of work. The list of safety alarms includes: coolant level sensor, flame control, fuel level, temperature in the heated room.

The boiler is certified for use in Russia.

    • Gas heating boilers Kiturami series TGB-30R, KSG-50R, KSG-70R, KSG-100R, KSG-150R, KSG-200, KSG-300R, KSG-400R. User manual. Language: RU | pdf 896.41 Kb

      Gas heating floor double-circuit coppers of Kiturami of the KSG series - 50/70/100/150/200/300/400. Instructions for installation, operation, service and repair. 2016 | Language: RU | pdf 5.35 Mb

      Gas double-circuit heating floor coppers of Kiturami of the STSG series - 13/17/21/25/30. Instructions for installation, operation and maintenance. 2016 | Language: RU | pdf 3.44 Mb

      Models TURBO 13-30R. Double-circuit heating boilers. Installation instructions. Language: RU | pdf 2.27 Mb

    • Models WORLD 5000 - 13/16/20/25/30R. Double-circuit heating boilers KITURAMI WORLD 5000. Technical data sheet. Language: RU | pdf 4.21 Mb

      Models WORLD 5000-13/16/20/25/30 R. Wall mounted gas boilers. Technical information and instructions for installation and service. Language: RU | pdf 2.91 Mb

      Gas wall-mounted boilers Kiturami series Eco condensing (open type) - 16H / 20H / 25H / 30H / 35H, (closed type) - 16D / 20D / 25D / 30D / 35D. Instructions for installation and operation. Language: RU | pdf 4.04 Mb

      Gas wall-mounted boilers Kiturami series TWIN ALPHA 13 / 16 / 20 / 25 / 30. Installation and operation instructions. Language: RU | pdf 6.95 Mb

      Gas wall-mounted boilers Kiturami series WORLD 5000 - 13 R, 16 R, 20 R, 25 R, 30 R, 35 R. Installation and operating instructions. Language: RU | pdf 3.27 Mb

      Technical information and instructions for installation and service. WORLD5000 - 13R (15.1 kW), WORLD5000 - 16R (18.6 kW), WORLD5000 - 20R (23.2 kW), WORLD5000 - 25R (29.1 kW), WORLD5000 - 30R (34.9 kW). Language: RU | pdf 2.91 Mb

      Gas wall-mounted boilers Kiturami series WORLD PLUS 13 / 16 / 20 / 25 / 30. Installation and operation instructions. Language: RU | pdf 2.76 Mb

    • Gas / liquid fuel boilers Kiturami STS series - 13 R, 17 R, 21 R, 25 R, 30 R stainless steel. User manual. Language: RU | pdf 2.77 Mb

      Liquid fuel heating boilers Kiturami series KSO-50 R, KSO-70 R, KSO-100 R, KSO-150 R, KSO-200, KSO-300 R, KSO-400 R. Operating instructions. Language: RU | pdf 1.13 Mb

      Liquid fuel heating boilers Kiturami series TURBO-9R, TURBO-13R, TURBO-17R, TURBO-21R, TURBO-30R. User manual. Language: RU | pdf 682.85 Kb

      Liquid fuel heating boilers Kiturami series CTR 5000. Operating instructions. Language: RU | pdf 7.04 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the KSO series - 50/70/100/150/200/300/400. Instructions for installation, operation, service and repair. 2016 | Language: RU | pdf 4.79 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the KSO HI FIN - 50/70/100 series. Instructions for installation, operation, service and repair. 2016 | Language: RU | pdf 3.04 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the STSO series - 13/17/21/25/30. Instructions for installation, operation and service. 2016 | Language: RU | pdf 3.94 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the STSO HI FIN - 13/17/21/25/30 series. Instructions for installation, operation and service. 2016 | Language: RU | pdf 4.30 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the TURBO series - 13/17/21/30. Instructions for installation, operation and service. 2016 | Language: RU | pdf 3.93 Mb

      Diesel heating floor double-circuit coppers of Kiturami of the TURBO HI FIN - 13/17/21/25/30 series. Instructions for installation, operation and service. 2016 | Language: RU | pdf 3.89 Mb

      Combined heating boilers Kiturami series KRM - 30R, KRM - 70R on solid and liquid fuels. Instructions for installation and operation. Language: RU | pdf 921.12 Kb

    • Bifuel coppers of Kiturami of the KRH - 35A series (liquid fuel + wood fuel). Instructions for installation and operation. Language: RU | pdf 3.49 Mb

  • The Korean company Kiturami focuses primarily on the manufacture and sale of heating equipment. All heaters of this brand symbolize high quality, which is the reason for such popularity of products. In production, only modern technologies are used, thanks to which the consumer is guaranteed to receive stable operation of the devices throughout the operational period. So, today we will talk about Kiturami diesel boilers, but first we will get acquainted with all the products of this company.

    Diesel boilers from the manufacturer

    All diesel fuel boilers from Kiturami are double-circuit and are manufactured in several series, let's get acquainted with them.

    1. - These are devices whose power can reach 35 kilowatts. The power, as we see, is insignificant, but there is a turbocyclone burner, and the cost is low. All models are designed for use in private houses or cottages, the area of ​​​​which does not exceed 350 square meters.
    2. Specifications Unit rev.
      Power kWh 15 19.8 24.5 35
      Heated area m2 up to 150 up to 200 up to 250 up to 350
      efficiency % 92.8 92.9 92.8 92.7
      Average heat consumption l/day 4.9-6.8 6.1-8.6 7.3-10.4 10.0-14.5
      DHW capacity l/min at T=40C 5.2 6.5 8.2 13.0
      Heat exchanger area m2 0.78 0.92 1.03 1.03
      Heat exchanger capacity l 23 32 29 29
      Boiler dimensions WxDxH mm 310x580x835 360x640x920 360x640x920 360x640x920
      Boiler weight kg 64 75 85 88
      Electricity consumption energy W/h 120 170 200 280

      Table of technical characteristics of boilers of the Kiturami Turbo model

    3. Kiturami STS- similar devices, differing in that they are made of stainless steel.
    4. Model Power
      Heating area
      DHW at dT 25 C HxWxD-mm The weight
      Kiturami STS 13 OIL 16.9 kW 160 sq.m 6.2 l/min 700x325x602 30 kg
      Kiturami STS 17 OIL 19.8 kW 190 sq.m 6.7 l/min 700x325x602 30 kg
      Kiturami STS 21 OIL 24.4 kW 240 sq.m 8.3 l/min 700x325x602 32 kg
      Kiturami STS 25 OIL 29.1 kW 290 sq.m 10.4 l/min 930x365x650 48 kg
      Kiturami STS 30 OIL 34.9 kW 340 sq.m 12.5 l/min 930x365x650 48 kg

      Table of technical characteristics of boilers of the Kiturami STS model

    5. Kiturami KSOG- high-power devices (up to 465 kilowatts) of a two-coil type, also consuming diesel fuel. These Kiturami diesel boilers have a built-in turbocyclone burner and are intended for operation at industrial facilities up to 4650 square meters, as well as for supplying hot water.

    Note! All mentioned boilers have an electronic control unit, which is equipped with numerous functions. In addition, the manufacturer provides for the possibility of installing a room thermostat, which allows you to control the temperature in the room directly on site.

    Table - Comparison of models and prices of Kiturami heat generators

    The lineup Name Power, in kilowatts Cost, in rubles
    Kiturami KSOG 50R 58 95.5 thousand
    200R 230 304 thousand
    150R 175 246 thousand
    100R 116 166.6 thousand
    70R 81 104 thousand
    Kiturami STS 30R 35 63 thousand
    25R 29 55 thousand
    21R 24 50 thousand
    17R 19 42 thousand
    13R 16 41 thousand
    30R 34 52 thousand
    21R 24 50 thousand
    17R 19 40.6 thousand
    13R 15 38 thousand

    Strengths and weaknesses of diesel units

    So, we found out that all boilers from this Korean manufacturer embody excellent quality, functionality, affordable cost and modern design. The fuel in this case can be both light oil and kerosene. If the burner is replaced, it is also possible to switch to natural gas.

    Other advantages of the devices include the presence of security sensors with which you can control the main work processes. Tellingly, when creating these sensors, a unique technology was used regarding the removal of fuel combustion products.

    A distinctive feature of the models of the Turbo series is that they include floor-mounted diesel heat generators that can not only heat the room, but also heat water for domestic needs. Therefore, there is no need to purchase an expensive boiler, because all models of this series already belong to boiler-type devices.

    Another advantage is the high degree of protection provided by the fact that the boilers are built in:

    • sensors;
    • forced removal of flue gases;
    • control bullets;
    • thermostat.

    The common advantages of all boilers of this manufacturer include the fact that they are quite capable of functioning in any conditions, and this is quite relevant for our country. And buying spare parts for Kiturami boilers is also not difficult, since the company has many dealerships.

    When compared with boilers made by other manufacturers, Korean models are distinguished by one of the most economical fuel consumption. And if we talk about the performance of hot water, then this figure can reach twenty liters per minute.

    And now let's talk about the main advantage of the described boilers - this, of course, is their affordable cost. To date, Kiturami diesel boilers can be purchased for the amount from 20-30 thousand rubles. Moreover, this equipment is distinguished by the widest model range, due to which the requirements of not only the owners of country houses, but also the management of industrial facilities will be satisfied.

    Model Kiturami Turbo-13R: comparative characteristics

    As an example, let's take one of the most popular models of boilers from this manufacturer, namely the Turbo-13R. It is characterized by the fact that it is made in the floor version and can be used both for heating and for providing warm water. The main advantage can be considered the presence of a turbocyclone burner.

    How is this burner different? First of all, it functions according to the technology of a turbocharged engine in a car: due to the high temperature, which can reach 800 degrees, the gas is completely burned out in a special metal plate (the so-called secondary combustion takes place). And thanks to this, you can not only save on resources, but also significantly reduce the amount of harmful substances released into the atmosphere.

    Note! To control this boiler, a special remote control is used, located on the front of the case.

    There is also an alternative to such control - a thermostat installed in one of the premises of the house. Among the functions of this device are:

    • integrated security (this includes self-diagnosis, combustion sensors, fuel shortage sensors, etc.);
    • programming;
    • lack of people in the room.

    To date, thousands of users have already tried and convinced themselves of the quality of this boiler. Many of them subsequently spoke about the high quality of not only Turbo, but of all Kiturami products as a whole.

    And this is how the boiler looks from the inside in an open, disassembled form:

    Video - Kiturami Turbo-13R

    Instrument installation and maintenance

    So, we found out that Kiturami heat generators have excellent characteristics, but it is worth remembering that during their operation the relevant requirements should be followed, otherwise the most reliable device in the world will require a major overhaul.

    The very first thing that many boiler users encounter is installing an already purchased model. During installation, it is necessary to adhere to all the requirements of the manufacturer, for this reason it is much better if qualified specialists take over the work - in this case, there will be no risk of having to repair the device immediately after the installation work is completed. Indeed, in most cases, the cause of an early breakdown of the device is just its incorrect installation. And to avoid all this, you have to pay a little extra.

    Due to the fact that the diesel heat generator is equipped with a fuel tank, certain operational requirements are also imposed on it. So, only pure fuel can be poured into the tank, in addition, it should be cleaned regularly, as well as the boiler itself. For this reason, when buying, you should pay attention to whether the tank is equipped with a sediment outlet pipe and a fix bag.

    Note! Before turning on the boiler itself, fill it with fuel and let it stand for at least twenty minutes. Only after that you can proceed to the device settings.

    If voltage drops often occur in your area, then do not spare the money and also buy a stabilizer that can save the functionality of the control unit and various sensors present in the device. But proper installation and competent operation is not all, because Kiturami diesel boilers need periodic preventive measures. Such activities consist of:

    • mechanical cleaning;
    • checking all nodes is not a matter of operability and the presence of leaks.

    Some of these works can be done with your own hands - for example, connect the device itself - but it is advisable to entrust the rest to professionals. And always remember the need to care for the heat generator, so carry out all these activities in advance. So you can avoid a number of minor problems, as well as prevent more serious ones.

    Kiturami boilers - customer reviews

    As noted above, Korean heating appliances are becoming increasingly popular and this is not surprising. All the people who bought diesel boilers of this brand and use them unanimously talk about the main advantage of the product - namely, the special design.

    Today's heat exchangers are made of high-alloy steel, which is significantly superior to its counterparts in terms of durability. At the same time, their contours are made of copper, which is why they are perfectly combined with antifreeze or ordinary water. It is thanks to this feature that boilers have a high thermal conductivity.

    Among other features noted by users, the electronic system, which is equipped with both indoor and outdoor consoles, deserves special attention, thanks to which the control procedure is noticeably simplified, and a person can observe the operation of the equipment from anywhere.

    Video - Diesel boilers Kiturami

    As a small conclusion

    When analyzing some models, we found a lot of advantages for boilers of this brand over their competitors, although even here they could not do without drawbacks.

    This applies in particular to liquid fuel (diesel) appliances. Each boiler that consumes diesel fuel is necessarily equipped with a special fuel tank, which in most cases has a very significant volume - from 2,000 to 5,000 liters. Boilers are equipped with such tanks, but in the absence of the latter, you will also have to fork out for the purchase of a “tank for diesel fuel”.

    To install such a boiler, it is necessary to have a room with excellent ventilation, so that the user does not accidentally get poisoned by fuel combustion waste. In some cases, heat generators even smoke, which is why they need special care. Finally, one should not forget about the cost of diesel heating appliances - it is often higher than that of appliances using other types of fuel (even though Kiturami boilers are cheaper).

    Despite all the strengths and weaknesses of such boilers, modern technologies make it possible to significantly increase the safety in the operation of space heating devices. And we all know that safety should come first. Moreover, this equipment can work autonomously, maintain the required temperature for a long time, even if there are no people nearby.

    Video - Kiturami Turbo-30R

    Assortment of Kiturami

    All heating boilers from this Korean manufacturer are divided into three categories, each of which has its own characteristics, strengths and weaknesses. This is:

    • diesel;
    • solid fuel;
    • gas heaters.

    Let's get acquainted with each of the types.

    1. Diesel devices, as the name suggests, operate on diesel fuel, which increases the efficiency of heating. The model range of such boilers will be discussed in more detail in the next paragraph.
    2. Solid fuel appliances are an alternative to the previous option, since they are quite capable of operating on both diesel and solid fuel, which is especially important in conditions of an unstable supply of energy resources. These boilers are made in such a way that after solid fuel is used, they begin to burn diesel itself. All diesel devices are combined into one model range - KRM. There is an automatic control, it is possible to use for domestic hot water purposes.
    3. Gas appliances use natural gas, which is why they are now very popular. They are floor or wall, for one or two circuits. They are quite convenient to operate, and the savings in their use are obvious.

    The work of the Kiturami concern is aimed at the production of heating devices for biofuels and gas. But it was diesel-fueled equipment that made this manufacturer popular.

    Advantages of diesel fuel installations:

    • Ease of use due to the ability to control any function using the remote control. The thermostat built into it determines the operating and temperature conditions. The operation of the boiler does not depend on the size and presence of draft, since the existing effect of turbocharging contributes to the forced direction of exhaust gases into the chimney;
    • High economic efficiency is achieved through aerodynamic flow during fuel combustion;
    • Possibility of self-configuration;
    • Year-round hot water supply;
    • The presence of a self-diagnosis system with information about the operation and malfunctions of the system;
    • Acceptable price;
    • Variety of lineup.

    The only negative is the type of fuel, which creates a negative environmental situation when it is burned.


    Equipment characteristics

    • The design, equipped with high-quality elements and blocks, is different from other brands. The heat exchanger is made of highly alloyed steel, superior in physical and technical qualities to other metals, which increases its cost, offset by high quality.
    • The equipment is made of copper, which does not react with water and increases its heat resistance. The presence of internal and external control units, which contributes to the regulation and control of the operating mode of the system from various places in the boiler room.
    • Coverage of the power range of floor-standing 2-loop units – from 10 to 35 kW, sufficient for heating 250-275 sq. m.
    • The dependence of the actual fuel consumption on personal settings. The nozzle is selected from the manufacturer for the actual power parameters.
    • Heating power, fuel consumption and its combustion mode are set independently. With power parameters up to 15 kW, the expected fuel consumption is 8 liters per day, while the burner will work with a certain frequency to create the optimal room temperature. By choosing the right heating mode and installing a variable temperature controller, you can significantly reduce fuel consumption.
    • Boilers for gas, diesel fuel, floor or mounted on the wall are mainly equipped with a closed-type combustion chamber and a forced gas exhaust system. A steel or ceramic chimney is coaxial so that the supply of street air flow and gas exhaust are carried out at the same time.
    • It is possible to build a chimney with a slightly larger diameter - up to 120 mm. Reducing its size and cross section is unacceptable.

    The lineup

    The development of KSO models was originally carried out as gas-powered equipment. After changing the type of burner and slightly changing the monitoring and control system, it became possible to use other energy sources. The main fuel was diesel. The turbocyclone burner contributed to 100% fuel combustion and increased efficiency. The advantages of the model are simplicity of design, ease of maintenance and low price.


    Biofuel boilers models KRM-30R and KRM-70R with changes made to their design, both diesel fuel and other solid fuels are used. The transition from one type of fuel to another is carried out quickly. The forced circulation system increases the efficiency of the heater. These models differ only in power.

    Model turbo 13r generates 13,000 kcal/hour of thermal energy or 15.1 kW, which is enough to heat 150 sq. m. The heat costs for the preparation of hot water supply are taken into account. With significant regular waste of boiling water, the thermal circuit power is lower.


    Model turbo 17 has a thermal power parameter of 19.8 kW, sufficient to heat 180 square meters. m. To increase the limit of the upper performance threshold, nozzles on the burner are selected, which may affect fuel consumption.


    Model turbo 21r with a capacity of 24.4 kW has an increased capacity of the DHW circuit. At the same time, the dimensions of the boiler remain unchanged.

    Liquid fuel model turbo 30 r has a capacity of 34.9 kW, sufficient for heating 350 square meters. m. Equipped with flame-shaped burners, the fuel combustion mode is optimal. Due to the small number of nitrogen oxides, it is a highly environmentally friendly equipment.


    Price

    • Turbo models 15-35 kW for heating 150-350 sq. m, weighing 52-85 kg - cost 28 thousand-37 thousand rubles;
    • STS models 17-35 kW for heating 160-350 sq. m, weighing 40-58 kg - cost 29 thousand-43 thousand rubles;
    • KSO models 58-465 kW for heating 580-4650 sq. m, weighing 93-750 kg - cost 75 thousand-428 thousand rubles.

    Owner reviews

    “In 2012, a Kiturami 17R boiler was purchased. Excellent purchase. He was supposed to work as an understudy for the Evan Epo-18 electric boiler, which acts as the main one in the heating system. Since an area of ​​150 sq. m, then the choice specifically fell on high-power equipment. In severe frosts, the main boiler cannot cope with maintaining the required temperature regime, it stops working due to a voltage drop in the network. Kiturami acts as a lifeguard by providing warmth and water.” Tambov, Arkady

    “The Kiturami Turbo boiler is of interest in terms of hot water due to the presence of the SHOWER function, which is capable of delivering a small amount of hot water in a short period of time.” Sochi, Marina

    “Wonderful equipment. No matter how many such systems have been installed, practically no one has any complaints. The whole of Siberia is warmed by them.” Yekaterinburg, Sergey

    “The cost of this equipment is already interesting. Spare parts are always in stock, the panels are unified.” Moscow, Konstantin

    “We have our own claims to the boilers of this company. In my opinion, they are not entirely reliable. So we had to resort to repairs twice. Automation fails." St. Petersburg, Alexander

    Installation and operation rules


    In the presence of power surges, it is desirable to purchase a stabilizer to ensure the correct operation of the control and monitoring unit and safety from premature failure

    The boilers are equipped with tanks for storing liquid fuel. These tanks can affect the performance of the equipment. It is necessary to properly install this container, which must be set on all planes.

    The tank must have a pipe for draining sediments and a fix bag. The container must be periodically emptied of fuel and cleaned; it is recommended to use only purified fuel.

    Before starting the equipment, diesel fuel is initially filled into the tank, which must settle for at least half an hour. Only after that the unit is started and the operating modes are adjusted.

    In the presence of power surges, it is desirable to purchase a stabilizer to ensure the correct operation of the control and monitoring unit and safety from premature failure.

    To keep the boiler working you need:

    • Periodic mechanical cleaning.
    • Constant monitoring of equipment performance and checking of components and parts for their leakage.

    Self-installation of diesel boilers is possible with a careful study of the schemes and recommendations of the manufacturer. However, there are many operations that require the presence of highly qualified specialists, so that later the equipment does not have to be repaired. The instructions for the exact order and principle of installation and the electrical installation diagram serve to illustrate the implementation of these works.

    Kiturami boilers are an economical option with a long service life. The reason for the premature repair is untimely service or low-quality fuel filling.

    Error codes:

    Reasons for no ignition - error code "01":

    • Jamming of the screw limiting the fuel level. It is necessary to replace the locking element or check the injection motor;
    • Injection motor failure– it will be necessary to check the performance of the motor;
    • Lack of fuel supply- you will need to check its level;
    • third party item in a screw gate;
    • Photosensor failure- it needs to be checked for functionality.

    • Diesel single-circuit and double-circuit models have been developed, the latter are more convenient, but more expensive. Choosing the first option, you need to purchase a boiler and other appliances and fixtures, but its cost will still be lower.
    • It is worth paying attention to the depth of the fuel intake according to the criterion for determining the deep location of the fuel and the fuel tank. According to fire safety, fuel tanks must be dug into the ground to an appropriate depth. With low power, the depth of the fence is higher.
    • The cost of installing the equipment will include the price of the heater, its installation, start-up and adjustment works, maintenance and spare parts during its repair.

    Heating the house in winter is a top priority for every homeowner today. Most of all, this issue is relevant for owners of suburban housing. And although modern gas boilers are the most advanced, they are inaccessible to many people due to the constant increase in the price of this type of fuel.

    Therefore, a large number of consumers choose other alternatives, one of which is the Kiturami diesel boiler. Although they are not new on the market, they have not lost their popularity at all. They are able to provide high-quality heating in the house.

    Today Kiturami is a well-known South Korean concern, one of the largest manufacturers of heating equipment. Repeatedly, the boilers of this company were awarded diplomas for reliability and technical perfection, and due to the presence of certificates that meet all international standards, the Kiturami diesel heating boiler is exported to almost all countries.

    What is the peculiarity of heating equipment from Kiturami?

    The Kiturami concern is engaged in the production of various types of heating equipment, which includes biofuel and gas installations. But it was Kiturami's diesel heating equipment that brought the concern such great fame and a high rating. The name diesel itself speaks of the type of fuel on which it runs.

    Rice. one

    The most popular model in the line of this manufacturer is the Kiturami Turbo 17 diesel boiler, the purpose of which is hot water supply and heating of industrial and residential premises. Boilers from the manufacturer Kiturami are very convenient for use in country houses, when the need for hot water does not arise daily, and heating is required only during the presence of the owners there. In addition, with proper operation, repair of such equipment is very rarely necessary.

    The main advantages of Kiturami diesel heating equipment include:

    • the diesel copper of Kiturami is convenient in operation. The control panel allows you to set any control function. Kiturami's work on the coolant and room temperature is regulated by a thermostat built into the remote control. The boilers are independent of the size of the chimney and the presence of draft due to the presence of a turbo blowing effect, which forcibly sends the exhaust gases to the chimney;
    • diesel Kiturami is highly economical. Thanks to the aerodynamic flow in the combustion chamber, maximum efficiency is achieved in terms of the amount of fuel consumed;
    • setting up the equipment is absolutely simple, and you can do it yourself;
    • The house has hot water all year round. Boilers of the Kiturami brand are also used at a time when the room is not heated;
    • The Kiturami diesel boiler has a self-diagnosis system that informs on the display about its operation and the malfunctions that have occurred, showing the real state of the system. If you constantly monitor the display readings, then the need for repairs will be minimal.

    Features of Kiturami in operation

    The diesel heating unit represented by the Kiturami concern differs significantly from other brands in its characteristics, both in terms of the method of maintenance and the need for repair. Only high alloy steel is used to manufacture the heat exchanger.


    Rice. 2

    Kiturami brand boilers are made of copper, which is highly resistant to water. If we talk about the price, then in comparison with stainless steel, copper is much cheaper, and, accordingly, a diesel boiler costs accordingly. In addition, copper significantly increases the heat resistance of equipment.

    The quality of the Kiturami Turbo depends on how correctly placed the tanks in which the fuel is stored. Here it is necessary to correctly place the tank and expose it in three surfaces. It is imperative to take into account that a drain is provided in the sedimentation tank. The Turbo tank should be cleaned regularly and sediment drained, and the diesel engine should only be filled with fuel in a cleaned form. Such handling contributes to trouble-free operation, and the need for repairs is not needed.

    When the Kiturami diesel boiler is filled with fuel, the instruction says that you need to wait half an hour until it settles. Only after this, the Turbo diesel boiler can be started and the necessary modes can be adjusted. It is also advisable to use a stabilizer to avoid repairs from sudden changes in mains voltage. It will ensure the stable operation of the control unit, as well as protect the heating unit from premature repairs.

    In order for the Kiturami diesel heating boiler to work smoothly during operation, the following is necessary:

    • the boiler setting must be carried out correctly and correctly, then the need for repairs will be minimal;
    • a diesel boiler requires the systematic implementation of its mechanical cleaning in order to protect it from premature repairs;
    • Turbo should regularly monitor the operation of all its connections and assemblies for leaks;
    • the performance of the equipment must be checked regularly so that it is not necessary to prematurely repair Kiturami diesel boilers.

    Equipment installation and connection

    All the requirements for connecting Kiturami are absolutely not difficult to fulfill on your own. You can install the Kiturami diesel boiler without the help of specialists, it is enough to carefully study the scheme and recommendations of the manufacturer. But at the same time, there are many operations that require the presence of qualified craftsmen in order to subsequently avoid incorrect actions.

    For those people who for the first time have to assemble heating equipment Kiturami diesel boilers, the instructions and the installation scheme will serve as a good example of such work. It is very important that the Kiturami Turbo is connected using the electrical diagram of the boiler and that all recommendations for connecting to the mains are clearly followed.

    Who is not sure that he can independently perform all the work on which the setting of the Kiturami diesel boiler directly depends, it is best to involve specialists, and thus avoid possible errors and premature repairs.

    The Kiturami diesel boiler requires an extremely precise order and principle of its installation, since an incorrect connection is most often the cause of equipment failure and it becomes necessary to carry out expensive repairs of Kiturami diesel boilers.

    Description of Kiturami malfunctions and repair

    The Kiturami diesel boiler belongs to the economy option and has a rather long service life. But there are situations when the boilers fail prematurely. The reason for the need to repair Kiturami is their untimely service or the use of poor quality fuel.

    A simple repair of Turbo boilers can be carried out independently, but it is more rational to contact service organizations in case of malfunctions.

    Rice. 3 Installed boiler Kiturami

    Below are the main error codes that the Kiturami Turbo 17 diesel boiler is most often exposed to:

    • when the lights on the display flash "01", "02" or "03" - it means that there are problems in the flame detector and ignition does not occur. The Turbo boiler in this case should be restarted according to the instructions;
    • error "04" indicates that the water temperature sensor is faulty in the Kiturami heating system, and repair in this case becomes inevitable;
    • error "08" warns that the path between the boiler and the temperature sensor is very long or a wire break has occurred in some place. Repairs will be required to identify the immediate cause of the failure;
    • error "95" means too low pressure in the heating circuit. The Turbo boiler must be energized and the entire heating system must be examined for the possibility of leaks;
    • error "96" - the mechanism that protects the Turbo system from overheating has worked;
    • error "98" - indicates that there is a lack of fuel in the supply line.

    Of all the errors described above, “01” flashes most often on the display, but this does not pose a great danger to the operation of the equipment. The diesel boiler Kiturami Turbo 17 is characterized by maximum efficiency. Thanks to the control panel, the boiler control functionality is achieved and room heating is possible in any temperature regime.

    In Turbo it is possible to regulate temperature parameters step by step from 45 to 75°С. All information about the operation of the diesel Kiturami Turbo on the thermostat screen is displayed by the self-diagnosis mechanism.

    Most often, the Kiturami diesel boiler gives error 01. This happens when there is no stable ignition in the Turbo.

    The reasons may be as follows:

    • when the screw jams, which serves as a fuel level limiter. The repair consists in the need to replace the locking element or check the injection motor;
    • when the blower motor fails. It is necessary to check the working condition of the Kiturami motor. If the motor is faulty, then the repair consists in replacing it with a new one;
    • when there is a lack of incoming fuel, then its level should be checked in the tank, in this case repairs will not be needed;
    • when a third-party object accidentally appears in the screw gate, then it must be removed during the repair process;
    • when the photosensor fails, the Turbo repair consists in checking this element for its operability.

    When the error code “01” periodically appears on the display, then in such cases it is necessary to seek help from the relevant specialists in order to avoid major costly repairs.

    Carrying out regular maintenance and repair of Kiturami is a guarantee that Turbo boilers will work efficiently and reliably. If irreparable damage occurs in the diesel boiler during the warranty period, then it is repaired without the need to pay for such work.

    The Kiturami Turbo diesel boiler has excellent performance, but it must always be remembered that non-compliance with the established installation scheme, correct settings and elementary rules for handling it in many cases ends with a total repair. When all requirements for use and operation are met, modern technologies for the production of Kiturami heating equipment guarantee each user stable operation of the boiler without the need for repair and a long service life.