Mongoose ems 1.9 wiring diagram. How to use autostart on Mongoose alarms. Special Functions of the LCD Controller
Most motorists prefer to use the Mongoose security system for their car.
Arguing this by the fact that it has easy control, quick installation, great quality and affordable cost.
ATTENTION! Found a completely simple way to reduce fuel consumption! Don't believe? An auto mechanic with 15 years of experience also did not believe until he tried it. And now he saves 35,000 rubles a year on gasoline!
The alarm system of this company contains many models. Let's take a closer look at some of this large list.
Mongoose ems 7.0
Mongoose ems 7.0 is a security system that is designed to provide comprehensive protection for a car. This alarm is controlled by remote and automatic engine start. To display the danger there is a sound and light alarm.
A danger signal is sent via a radio signal to a pager located in the alarm remote control. Also, this model prevents, unauthorized by the owner, starting the engine.
Significantly simplifies the use of the Mongoose EMS 7.0 alarm system - autostart. He can remotely turn on the alarm or start the engine.
This happens automatically, you just need to decide on the time and frequency. The system is designed to work on machines with any engines and gearboxes. Starting the engine is completely safe.
In order for no one to get into the system, the protection of the radio command code is thought out in advance. It will be able to prevent any attempts to intercept codes. An anti-scan function is available, which is necessary to protect against disabling the alarm by selecting any codes. There is also a state memory function. Thanks to her, an attacker will not be able to remove the car from the alarm by attaching the car battery terminal. As a result, the machine will simply return to the mode that was previously set and the engine will be blocked.
Mongoose ems 1.7
Mongoose ems 1.7 is a car security system that will be useful to you both in the parking lot, on the way, and at “minute” stops. When creating this alarm, the principle of protection of different levels was used to prevent penetration into the car and theft. This system has the ability to control at a distance.
If, after disarming the car, no additional actions have taken place that indicate that it was the owner of the vehicle who did it, then the key fob will receive a signal about the threat of theft and an alarm will go off. It is also possible to set the permanent removal of the car from protection at the same time, without the participation of the remote control.
Mongoose ems 1.9 is a car security system, which includes engine start control.
This means that it not only helps to prevent car theft, but also to start the engine at any time. convenient time. This function helps to save a lot of time in winter time of the year.
The biggest plus of Mongoose ems 1.9 is the wiring diagram. Installation is easy, connection of the system does not require special knowledge. The instruction is attached and it tells how to properly set up the alarm and activate all the necessary functions. It will not be difficult to buy this security system, since the company is well-known and the cost is affordable.
Contents of delivery:
- Central control unit.
- Communication module.
- Bi-directional control panel with built-in multi-channel pager, LCD display for alarm and system status indication, sound emitter, vibrating alert and five control buttons with sound confirmation of command transmission.
- Unidirectional remote control with two buttons.
- Dual level shock sensor.
- Indicator LED.
- Button emergency shutdown.
- Wire harness kit.
- Installation kit.
- User manual (in Russian and English).
- Installation instructions (in Russian and English).
Mongoose EMS 1.9R specific features:
- Programmable arming function with a key.
- Engine protection.
- Safe activation procedure.
- Ignition support function. - Quiet guard mode.
- Alarm indication only by signal lights and through the pager channel, without turning on the siren. - Passive immobilizer mode.
- Keeping the engine blocking after the system is disarmed.
- Shutdown by a programmed combination of buttons on the remote control or PIN code (User authorization).
- Turn on the alarm when you try to turn off the mode with the wrong command.
- Programmable alarm activation function if the immobilizer is not disabled within a specified period of time after disarming the system. - Anti-hijack function Anti-Hi-Jack.
- Programmable automatic activation when the door is opened with the ignition on.
- Remote activated activation when opening the door for one trip.
- Secure multi-step activation procedure. - Blocking the engine with imitation of a malfunction.
Remote deactivation of the warning zone of the shock sensor and additional sensor. - Programmable alarm activation delay when the door is opened.
- LED indication of the number of programmed control panels.
- Programmable status output operation mode: for connecting a normally closed or normally open relay.
- Remote activation of the test mode of the pager.
- Selecting the mode of signal transmission to all control panels known to the system, or only to the panel by which the system was armed.
- Disarm warning function.
- Programmable double pulse unlocking.
- Two-step unlocking of doors when disarmed and ignition on.
- Two 2-level sensor inputs.
Engine start control system EMS 1.9R:
- Remote engine start.
- Daily start of the engine at a specified time according to the internal clock of the central alarm unit.
- 24 hour engine start according to the internal clock of the central signaling unit.
- Periodic and forced synchronization of the clock of the control panel with the clock of the central signaling unit.
- Periodic start of the engine according to the internal timer.
- Fast task from the control panel of the period of start and time of operation of the engine. - Periodic start of the engine when the temperature drops.
- Fast task from the control panel of temperature of start. - Safe start mode for vehicles with manual transmission.
- diesel mode.
- Turbo timer.
- Programming the engine shutdown delay after disarming.
- Programming the ACC output turn-on delay.
Special Features LCD control panel:
- System status indication.
- Real time clock.
- Set the daily start time.
- Indication of enabled modes.
- Parking timer.
- Separate switching off / on of the sound signal and vibrating alert.
Battery discharge indicator. - Button lock.
- Power saving mode.
- Checking the status of the security system.
Additional control channels:
- Tailgate release.
- Programmable output
- Window closing output when arming (“Comfort”).
- Two-step door unlocking. - Additional channel with program selection of one of 2 functions:
- Supplying power to the brake light circuit when starting the engine remotely.
- Impulse with fixation. - Central lock control input (with the possibility of arming).
- Control input (positive polarity) with software selection of one of 2 functions:
- Positive limit switch.
- Sound warning about lights not turned off.
Two Way Car Alarm System MONGOOSE EMS 1.9R
User's Guide
Introduction
Thank you for purchasing our car alarm system.
Mongoose EMS 1.9R is a modern car security system, designed and manufactured to ensure
the highest level of security for your car and provide you with a number of convenience features.
Please carefully read this manual and follow its instructions while using different features and
functions of the Mongoose EMS 1.9R.
We are not responsible for any injuries or damages resulting from your wrong use of our
Do not change the Installer's Functions while using the alarm system. These functions are
to be adjusted by professional installation staff, and to tailor the alarm system for reliable and
safety operation along with the different equipment installed on your car.
If you find any problems while using the alarm system, contact your installation shop for
repairing or re-adjusting. Do not try to repair the alarm system yourself.
After reading this Guide you will be able to make good use of your alarm system and get as full
as possible protection for your car.
The Mongoose EMS 1.9R monitors the status of the doors, hood and trunk, two stage shock
sensor and the optional e.g. space disturbance sensor (if installed). A power siren, light
indicators, and a pager system will warn you about any intrusion into your car.
Enhanced anti theft facilities are ensured by a powerful built in blocking relay and an
additional universal output available to connect an extra blocking relay with either normally
closed or normally opened contacts. The Passive Immobilizer function and programmable
disarm authorization procedure are included to enhance the protective abilities of the
alarm system.
Variable functions of the inputs and outputs add flexibility to the installation procedure and
daily usage of the alarm system; optional sensors and other equipment can be connected.
Built in relays are used to connect high current circuits.
The alarm system allows adjustment through programming a number of features to tailor the
system to particular car and extra installed equipment.
The self diagnostics feature helps to identify and quickly remove all possible faults.
The alarm system includes an engine start facility, which allows safety and reliable starting
the engine on both gasoline and diesel as well as on both automatic and manual transmission
vehicles.
remote control
Two Way Hand Held LCD Transceiver
5 button LCD Transceiver. The Transceiver has four buttons for controlling the alarm system
and the remote start system and one button (Button S) for configuring the display. The transceiver
radio remote control incorporates random encryption technology so that the control code is
changed each time the transmitter is used. Once the transceiver receives a status change or
alarm triggered signal from the main alarm unit the LCD indication will change accordingly
and audible/vibration warning will turn on to warn you the alarm is triggered.
User's manual
EMS 1.9R
User function table
switch function
Factory
Button 1
Button 2
installation
Auto arming
OFF
Locking doors during auto-arming
OFF
Automatic re-arming
Locking the doors when the ignition is turned on
Acoustic signals confirming the execution of commands
Disarm warning function
OFF
Transmission of signals to all control panels known to the system
OFF
Passive immobilizer
OFF
Activation of Anti Hi jack when opening the door
remotely
Automatic
remotely
included
activation at
included
activation
activation
opening the door
Warning zone activation indication
sensor on the bi-directional control panel
Change PIN code 1
÷9 (button 2 only).
Change PIN code 11
÷99 (button 1+button 2)
Press required
Press required
number of times for
number of times for
tens input
unit input
Erasing the codes of all remotes except the one you are using
Press buttons 1&2 together
Return to factory settings
Press buttons 1&2 together
Button(s) to disable the passive immobilizer.
Button 1
To enter the programming mode, press buttons 1 and 2
simultaneously. Press both buttons when installation is complete.
again to exit the mode.
Turning on the alarm when the passive is not turned off
OFF
For selection
immobilizer after disarming ( ASL
duration
delays
inclusion
LED indication:
alarm press:
15 seconds - single flashes
1 time - 15 sec
30 seconds - double flashes
2 times - 30 sec
60 seconds - triple flashes
3 times - 60 sec
Door open alarm delay
OFF
For selection
duration
delays
inclusion
LED indication:
alarm press:
15 seconds - single flashes
1 time - 15 sec
30 seconds - double flashes
2 times - 30 sec
Transition to installation programming
Press buttons 1&2 together
Press the buttons in the selected
sequences: 1; 2; 3; M; one
⇒2; 1⇒3; 1⇒M; 2⇒1; 2⇒2; 2⇒3;
⇒M; 3⇒1; 3⇒2; 3⇒3; 3⇒M; M⇒1;
⇒2; M⇒3; M⇒M;
* ATTENTION! When deleting the remote control codes, the system also deletes the central control codes.
block from the memory of control panels (if they are within the communication zone).
This takes approximately 8 seconds. After that, the system re-registers the code cent
remote control unit to the memory of the remote control used when erasing. If you don't want to wait
the end of the erasing procedure, program the remote control you are using as described
above to restore the pager function.
Installation instructions
EMS 1.9R
INSTALLATION INSTRUCTIONS
Attention! This part of the manual is intended for professional users only.
Disconnect the “ ” battery terminal of the car before starting the installation.
1. The central alarm unit is installed inside the cabin, away from the source
kov moisture and heating.
2. Antenna communication module, for maximum work efficiency
pagers should be placed as high as possible, away from metal panels
bodywork and wiring harnesses of the vehicle.
3. The siren is installed under the hood or in another place inaccessible to the hijacker
mouthpiece down or to the side. The installation location must be away from sources
heating and protected from water ingress. In case of installation of a siren with autonomous
supply, it is necessary to provide access to the service key lock.
4. The hood and trunk limit switches are installed in protected from
moisture in places inaccessible when the hood or trunk is closed.
5. The shock sensor is installed in the car interior on the body metal using
self-tapping screws or glued, as close as possible to the longitudinal axis of the vehicle.
6. All power circuits must be protected by fuses according to
flowing currents.
Specifications.
Supply voltage
Current consumption in armed mode
Radio channel frequency
Operating temperature range
Maximum allowable current
engine blocking circuits
signal light circuits
central lock control circuits
engine start control circuits
Pager modulation type
Control signal modulation type
Range of the bi-directional remote control
Measurement conditions
Pager channel
Control channel
Urban development out of line of sight
Line of sight in urban environments
Direct visibility outside the city
Car security system “MONGOOSE” Model EMS 1.9R
RUSSIAN
Programming of control panels.
control and 1 unidirectional, however, the alarm system is able to remember up to 4 two-way
directional and 4 unidirectional control panels, and if you have any need
the need to increase the number of remotes to control your security system,
You can program them using the following procedure:
1. Enter PIN code, for which turn on the ignition, press the emergency stop button
number of times equal to the first (or only) digit of the PIN code and turn off
ignition. If a 2-digit PIN code is set, turn the ignition back on to
press the emergency stop button a number of times equal to the second digit of the PIN code and
turn off the ignition. If the code is entered correctly, the system will beep twice.
a signal will inform you about entering the keyfob programming mode.
2. When you have finished entering the code, turn the ignition back on.(immediately after the double beep
3. Press button 1 on the remote control to be programmed. A short beep will confirm
writing the remote control code to the system memory. After the beep, wait for the double
flashes of the signal lights icon on the bi-directional LCD display
remote control, confirming the entry of the alarm block code into the remote control memory. remember
those when recording the fifth bi-directional or fifth uni-directional remote,
the first one recorded will be automatically deleted from the system memory, when recording
sixth - second, etc. If necessary, delete sweat codes from the system memory
remote controls, use the program switch 3 2 in the user table
Telsky programming.
4. To exit the remote programming mode, turn off the ignition and press
push the emergency stop button or wait 15 seconds. About exit mode
the system will notify you with a double beep.
WARNING: When programming bi-directional remote controls, the
the code of the remote control is written to the memory of the security system, as well as the code of the security
system into the remote pager memory. The pager memory of the control panel can be
the code of only one security system is recorded in order to avoid confusion when displaying
remote alarm and other information about the state of the security system. If you ho
Please use the same remote to control multiple Mongoose systems
EMS 1.9R , remember that when programming the remote control into the memory of the next security
system, the previous code is erased from the remote control memory, so the pager function will
det is available only in the last security system of those where the remote control is programmed
management.
Installation programming.
To change the settings for programmable functions, you must first
de, perform programming of the control panels. Then execute the following
procedure:
1. Having finished programming key fobs, turn on the ignition.
2. Press the emergency stop button 4 times (each press will confirm the system
emitted by a long beep), switch the ignition off and on again, and