Mongoose ems 1.9 how to enable autorun. How to use autostart on Mongoose alarms. Special Functions of the LCD Controller
The problem of setting up autostart and other Mongoose alarm functions may arise if a car owner who has recently installed a security system on his vehicle, for some reason there is no instruction for the alarm or it is not Russian-speaking.
This rarely happens, but nevertheless, therefore, in the article we will describe what to do if the alarm is not set to autostart and try to solve your problem.
ATTENTION! Found a completely simple way to reduce fuel consumption! Don't believe? An auto mechanic with 15 years of experience also did not believe until he tried it. And now he saves 35,000 rubles a year on gasoline!
There are many models of Mongoose alarms, but among those in which autorun is installed, the general principles of settings are the same. Therefore, owners of different alarm models will press the same buttons, for example, remotely start the engine, turn on or turn off some function.
We give as an example a table from the instructions for signaling the Mongoose EMS 1.9R model. As you can learn from the experience of owners of various models of car security systems of this brand, the setting buttons for each model are the same. Therefore, we recommend that you familiarize yourself with the table and try to solve your problem by configuring Mongoose autostart using it.
Explanation of the table: dot - single short press, therefore, three dots in a row - three consecutive short presses; dot and number next to it - press (number - number of times) and hold for about a second, that is, a dot and next to "2" - two long presses; dot and number of seconds - pressing and holding the button.
The button designations on the remote control are the same for all Mongoose alarm models. The layout of the buttons is shown below.
If you use the table, but nothing works out for you, that is, the alarm does not respond or does not respond correctly, it is likely that the alarm wiring is not connected according to the instructions. Often, only some functions do not function for car owners, for example, autostart by temperature does not turn on or it is not possible to set the engine operation time when low temperature then you can only help official instruction in your alarm system or a good electrician. Well, as an option, in this case, empirically, you can “feel” the right combination of buttons to activate autorun or any other functions - this is very time consuming and not the fact that everything will work out.
Peculiarities
It will not work to set the alarm to autostart if the neutral gear is not on (for cars with a manual transmission). A car with automatic transmission must be in parking mode, otherwise the engine will not start either.
Some Mongoose models are more finicky and remote engine start is performed only when the alarm is armed and the car is on the handbrake.
Modern alarm models are equipped with a huge set of functions that are configured from the key fob:
- remote engine start,
- daily start of the internal combustion engine at a given time,
- starting the internal combustion engine according to the internal alarm timer,
- safe start mode for cars with manual transmission,
- "automatically turn off the car" mode,
- the starter crank time is set automatically.
In addition, most alarms have a mass additional options, like the possibility of programming a delay in turning off the engine after deactivation security module, installation minimum temperature, at which the engine will start and its warm-up time, so the number of combinations used to configure the system, as you understand, is not small. So, if something does not work, it will be very difficult to figure it out without instructions.
Basic commands on popular alarm models
Below we provide button combinations for executing certain commands on alarms of specific models. The designations of the buttons on the main key fob are the same as in the diagram that we presented earlier; the designations of the buttons of the additional one-way key fob in the diagram below - it has only two buttons, so it will not work to set the autorun time or perform other settings with it - all this is done on the main key fob.
MONGOOSE EMS 1.9
Main keychain (double-sided):
- remote engine start: successive pressing of M and 1,
- turn off the engine: sequentially press M and 1.
Additional keychain (one-sided):
MONGOOSE EMS 1.9R
Main Keychain:
- remote engine start: successive pressing S and 1;
- turn off the engine: sequentially press S and 1.
Additional keychain:
- engine start (maximum from 20-30 meters): two short presses on button 1.
And to disable autorun, you need to press the same combination of buttons that it turns on.
We recommend when you find serious problems with the operation of the alarm, contact service center. And if you are going to purchase an alarm, then make sure that the kit will have instructions in Russian.
Contents of delivery:
- central block management.
- Communication module.
- Bi-directional control panel with built-in multi-channel pager, LCD display for alarm and system status indication, sound emitter, vibrating alert and five control buttons with sound confirmation of command transmission.
- Unidirectional remote control with two buttons.
- Dual level shock sensor.
- Indicator LED.
- Button emergency shutdown.
- Wire harness kit.
- Installation kit.
- User manual (in Russian and English).
- Installation instructions (in Russian and English).
Mongoose EMS 1.9R specific features:
- Programmable arming function with a key.
- Engine protection.
- Safe activation procedure.
- Ignition support function. - Quiet guard mode.
- Alarm indication only by signal lights and through the pager channel, without turning on the siren. - Passive immobilizer mode.
- Keeping the engine blocking after the system is disarmed.
- Shutdown by a programmed combination of buttons on the remote control or PIN code (User authorization).
- Turn on the alarm when you try to turn off the mode with the wrong command.
- Programmable alarm activation function if the immobilizer is not disabled within a specified period of time after disarming the system. - Anti-hijack function Anti-Hi-Jack.
- Programmable automatic activation when the door is opened with the ignition on.
- Remote activated activation when opening the door for one trip.
- Secure multi-step activation procedure. - Blocking the engine with imitation of a malfunction.
Remote deactivation of the warning zone of the shock sensor and additional sensor. - Programmable alarm activation delay when the door is opened.
- LED indication of the number of programmed control panels.
- Programmable status output operation mode: for connecting a normally closed or normally open relay.
- Remote activation of the test mode of the pager.
- Selecting the mode of signal transmission to all control panels known to the system, or only to the panel by which the system was armed.
- Disarm warning function.
- Programmable double pulse unlocking.
- Two-step unlocking of doors when disarmed and ignition on.
- Two 2-level sensor inputs.
Engine start control system EMS 1.9R:
- Remote engine start.
- Daily start of the engine at a specified time according to the internal clock of the central alarm unit.
- 24 hour engine start according to the internal clock of the central signaling unit.
- Periodic and forced synchronization of the clock of the control panel with the clock of the central signaling unit.
- Periodic start of the engine on the internal timer.
- Fast task from the control panel of the period of start and time of operation of the engine. - Periodic start of the engine when the temperature drops.
- Fast task from the control panel of temperature of start. - Safe start mode for vehicles with manual transmission.
- Diesel mode.
- Turbo timer.
- Programming the engine shutdown delay after disarming.
- Programming the ACC output turn-on delay.
Special Features LCD control panel:
- System status indication.
- Real time clock.
- Set the daily start time.
- Indication of enabled modes.
- Parking timer.
- Separate switching off / on of the sound signal and vibrating alert.
Battery discharge indicator. - Button lock.
- Power saving mode.
- Checking the status of the security system.
Additional control channels:
- Tailgate release.
- Programmable output
- Window closing output when arming (“Comfort”).
- Two-step door unlocking. - Additional channel with program selection of one of 2 functions:
- Supplying power to the brake light circuit when remote start engine.
- Impulse with fixation. - Central lock control input (with the possibility of arming).
- Control input (positive polarity) with software selection of one of 2 functions:
- Positive limit switch.
- Sound warning about lights not turned off.
Installation instructions
EMS 1.9R
INSTALLATION INSTRUCTIONS
Attention! This part of the manual is for professional use only.
Disconnect the “ ” battery terminal of the vehicle before beginning installation.
1. The central alarm unit is installed inside the cabin, away from the source
kov moisture and heating.
2. Antenna communication module, for maximum work efficiency
pagers should be placed as high as possible, away from metal panels
bodywork and wiring harnesses of the vehicle.
3. The siren is installed under the hood or in another place inaccessible to the hijacker
mouthpiece down or to the side. The installation location must be away from sources
heating and protected from water ingress. In case of installation of a siren with autonomous
supply, it is necessary to provide access to the service key lock.
4. Limit switches hood and trunk are installed in protected from
moisture in places inaccessible when the hood or trunk is closed.
5. The shock sensor is installed in the car interior on the body metal using
self-tapping screws or glued, as close as possible to the longitudinal axis of the vehicle.
6. All power circuits must be protected by fuses according to
flowing currents.
Specifications.
Supply voltage
Current consumption in armed mode
Radio channel frequency
Operating temperature range
Maximum admissible current
engine lock circuits
signal light circuits
central lock control circuits
engine start control circuits
Pager modulation type
Control signal modulation type
Range of the bi-directional remote control
Measurement conditions
Pager channel
Control channel
Urban development out of line of sight
Line of sight in urban environments
Direct visibility outside the city
Car security system “MONGOOSE” Model EMS 1.9R
RUSSIAN
Programming of control panels.
control and 1 unidirectional, however, the alarm system is able to remember up to 4 two-way
directional and 4 unidirectional control panels, and if you have any need
the need to increase the number of remotes to control your security system,
You can program them using the following procedure:
1. Enter PIN code, for which turn on the ignition, press the emergency stop button
number of times equal to the first (or only) digit of the PIN code and turn off
ignition. If a 2-digit PIN code is set, turn the ignition back on to
press the emergency stop button a number of times equal to the second digit of the PIN code and
turn off the ignition. If the code is entered correctly, the system will beep twice.
a signal will inform you about entering the keyfob programming mode.
2. When you have finished entering the code, turn the ignition back on.(immediately after the double beep
3. Press button 1 on the remote control to be programmed. A short beep will confirm
writing the remote control code to the system memory. After the beep, wait for the double
flashes of the signal lights icon on the bi-directional LCD display
remote control, confirming the entry of the alarm block code into the remote control memory. remember
those when recording the fifth bi-directional or fifth uni-directional remote,
the first one recorded will be automatically deleted from the system memory, when recording
sixth - second, etc. If necessary, delete sweat codes from the system memory
remote controls, use the program switch 3 2 in the user table
Telsky programming.
4. To exit the remote programming mode, turn off the ignition and press
push the emergency stop button or wait 15 seconds. About exit mode
the system will report double sound signal.
WARNING: When programming bi-directional remote controls, the
the code of the remote control is written to the memory of the security system, as well as the code of the security
system into the remote pager memory. The pager memory of the control panel can be
the code of only one security system is recorded in order to avoid confusion when displaying
remote alarm and other information about the state of the security system. If you ho
Please use the same remote to control multiple Mongoose systems
EMS 1.9R , remember that when programming the remote control into the memory of the next security
system, the previous code is erased from the remote control memory, so the pager function will
children is only available in the latest security system of those where the remote is programmed
management.
Installation programming.
To change the settings for programmable functions, you must first
de, perform programming of the control panels. Then execute the following
procedure:
1. Having finished programming key fobs, turn on the ignition.
2. Press the emergency stop button 4 times (each press will confirm the system
emitted by a long beep), switch the ignition off and on again, and