Ariston bs ii 24 ff three-way valve. Heating systems for country and country houses. Boilers, geysers, water heaters - Repair, service, operation. Recommendations for assembly and installation. Double-circuit wall heating systems

BS gas heating boilers are the best equipment for those who understand economy. Wall-mounted boiler with a capacity of 24 kW for heating and hot water supply is compact, lightweight, has two reliable separate heat exchangers and a unique hydraulic group.

The new equipment is distinguished by an affordable price, which makes it an extremely attractive product on the heating market.

Recommended for apartment heating and hot water supply in high-rise city buildings. Its use will reduce the cost of each consumer for heating (in comparison with the existing central heating) by about 2-3 times. Having your own boiler, you decide when and what temperature it needs to maintain in the apartment. Individual comfort, perfect value for money!

Main benefits:

    fully adapted for Russia - work at reduced gas pressure (up to 5 mbar), low pressure and water flow;

    resistance to voltage drops;

    built-in condensate collector;

    operation at low outdoor temperature (up to -52°С)

    analog control panel with temperature display

    the possibility of reducing the power for heating (with the same power for hot water) and the function of switching on delay

    function of continuous electronic modulation of the burner flame

    anti-freeze, scaling and blocking functions of the circulation pump and 3-way valve

    self-diagnosis function

    primary heat exchanger made of copper with a protective coating,

    secondary stainless steel plate heat exchanger

    durable stainless steel burner with safety feature

    heavy-duty composite hydraulic group, motorized three-way valve

    2 ultra-precise ntc temperature sensors

    2 mechanical cleaning filters - in the heating and hot water circuit

    expansion tank 8 l.

    self-diagnosis function

    Possibility to connect t-control and room thermostat


For high-quality heating of the premises of private houses of medium size (250-300 m²), the Ariston BS24FF boiler, operating on natural gas, is perfect. This is a fairly reliable product of a well-known Italian brand, which is distinguished by an acceptable cost. Unfortunately, the instruction manual attached to it rather briefly describes the device and functions of the heating unit, so it is worth considering them in more detail.

General overview of the heat generator

The Ariston BS II 24 FF household water heater is a gas wall-mounted heat generator equipped with a closed combustion chamber and forced combustion air supply using a fan (suction). Due to this organization of fuel combustion, the efficiency of the unit is 93.8% in normal mode and 89.3% with minimal combustion. To remove flue gases from the house, a double-walled coaxial chimney is used.


Theoretically, the rated power of the boiler is 25.8 kW, which is enough to service the water heating system of a private cottage with an area of ​​up to 300 m², located in the central zone of the Russian Federation and properly insulated. With poor insulation or lack thereof, the power of the device is enough to heat no more than 250 m² of area.

The Ariston BS 24 gas boiler is a modern multifunctional unit that can operate in automatic mode and does not need constant supervision by the homeowner. In addition, it is equipped with a second heating circuit for preparing water for the needs of hot water supply.

As the instruction says, the device includes the following main components and elements:

  1. Controller. This is the electronic brain of the boiler, which controls its operation based on the readings of temperature, pressure and draft sensors, as well as signaling the current mode or malfunction.

  2. Burner device of modulating type. It can smoothly change the intensity of combustion at the command of the controller, thereby adjusting the power of the heat generator.
  3. primary heat exchanger. Serves for heating water in the heating network.
  4. secondary heat exchanger. Heats tap water for domestic hot water.
  5. Safety gas valve. Shuts off the gas supply regardless of the controller in case of emergency. These include a drop in fuel pressure in the line below 5 mbar, the disappearance of draft in the chimney and spontaneous extinction of the burner.
  6. Closed combustion chamber, insulated with basalt fiber.
  7. A fan that supplies air to the chamber and removes flue gases from there through a coaxial chimney.

In addition to the main elements, the Ariston BS 24 FF boiler is equipped with additional devices that turn it into a wall-mounted mini-boiler room.

This is a circulation pump equipped with an automatic air vent, and a membrane-type expansion tank with a capacity of 8 liters. The heat generator heats water for heating up to a temperature of 85°C, for hot water supply - up to 60°C. The operating pressure range in the heating system is from 0.6 to 1.5 bar, the maximum is 3 bar.


The maximum pressure for which the DHW circuit is designed is 7 bar. The wall-mounted boiler is able to provide water consumption for household needs up to 10 l / min when it is heated by 35 ° C.

Functions of the thermal unit

The wall-mounted gas boiler Ariston is equipped with many functions, which allows you to operate it with maximum comfort:

  • convenient front panel with operating temperature indicators and a pressure gauge showing the pressure in the heating network;
  • electric ignition, carried out in automatic mode;
  • protection against power surges in the network, freezing and the appearance of a layer of scale;
  • adaptability to Russian operating conditions at low gas pressure;
  • smooth change of burner operating modes (modulation), which allows burning fuel with maximum efficiency;
  • the possibility of switching to liquefied gas;
  • the unit is equipped with a container for collecting condensate flowing from the secondary heat exchanger when heating water for domestic hot water;
  • Possibility of connection of weather-compensated automation and room thermostat.

For the manufacture of elements of the heat generator, appropriate materials were used to ensure a long service life. The heating heat exchanger is made of copper and has an additional protective coating, the hot water treatment unit is made of stainless steel. The burner is also made of stainless steel and protected from clocking (frequent shutdowns).

Starting and running the heater

The instruction manual for the Ariston boiler says that to start it, just press the "ON" button, the controller of the device will do the rest. If after 10-12 seconds the start did not occur, then it is necessary to reset it with the "Reset" button and repeat the inclusion. A repeated unsuccessful start means that the automation does not allow switching on due to a malfunction. According to the instructions, you need to contact the service department, but some problems can be detected on your own:

  • low pressure in the heating network;
  • the heating system is filled incorrectly, there are air pockets in the boiler;
  • electrical network failures.

In accordance with the rules, the connection of a gas heating unit to the gas main and a test run must be carried out by specialists of an organization that has a permit for these types of work. Therefore, the first inclusion should not cause you problems.

After the burner is turned on, heating of the coolant begins up to the temperature set by the regulator on the front panel. If at this time the hot water tap is opened, the flow sensor in the boiler will work, and the three-way valve will switch the heat carrier flow to the second heat exchanger. The water in the DHW circuit will heat up to the temperature set by the second regulator.

Characteristics and operation of the boiler Ariston BS ii 24 ff

The double-circuit gas boiler Ariston BS 24 FF is a versatile and compact mini-boiler room containing all the necessary components.

A wall-mounted boiler is used to heat small rooms with an area of ​​50-240 m2, in which it is impossible to install a floor heater, as well as to supply an object with hot water.

Rice. 1. Control panel of the gas wall-mounted boiler Ariston BS ii 24 ff

1. Green LEDs showing temperature and alarms, 2 . ON/OFF button, 3. Green LED ON/OFF, 4. Manometer (pressure in the heating circuit), 5. Yellow LED for signaling anomalies in the smoke exhaust system, 6. Summer/winter switch - Heating system temperature controller, 7. Domestic hot water temperature controller, 8. Socket for programming timer (option), 9. Red LED - column blocking signal, 10. Reset button / Chimney cleaning function, 11. Red LED for overheating signaling

Rice. 2. General view of the gas wall-mounted boiler Ariston BS 24 ff

1. Flue gas outlet, 2. Pressure switch, 3. Condensate trap, 4. Primary heat exchanger, 5. Overheating thermostat, 6. Heating circuit flow temperature sensor, 7. Burner, 8. Ignition electrodes, 9. Ignition device, 10 Gas valve, 12. Heating circuit safety valve (3 bar), 13. Secondary heat exchanger, 14. Drain cock, 15. DHW flow sensor, 16. Charging cock, 17. Heating circuit filter, 18. Circulation pump with air vent , 19. Heating return temperature sensor, 20. Three-way valve actuator, 21. Flame control electrode, 22. Mineral fiber combustion chamber thermal insulation panel, 23. Combustion chamber, 24. Expansion tank, 25. Fan, 26. Point analysis of combustion products

Technical characteristics of the gas boiler Ariston BS ii 24 ff

Rated thermal power for the heating circuit, no more / no less than (Hi) kW - 25.8 / 11.0

Rated thermal power for the heating circuit, not more / not less than (Hs) kW - 28.7 / 12.2

Output heat output (heating mode), no more / no less than kW - 24.2 / 9.8

Fuel combustion efficiency (measured at the outlet of combustion products), Hi / Hs% - 94.5

Efficiency at rated power (60/80 °C), Hi/Hs % - 93.8 / 84.5

Efficiency at 30% of nominal power (47 °C), Hi/Hs% - 93.6 / 84.3

Efficiency at minimum power, Hi / Hs% - 89.2 / 80.3

Heat loss through the chimney with the burner on % - 5.5

Heat loss through the chimney with the burner off % - 0.4

Residual pressure in the circuit Pa - 100

Flue gas temperature (G20) °C - 105

The amount of combustion products, not more than (G20) m3 / h - 56.8

Excess air % - 72

Maximum hydraulic resistance (dT=20°C) mbar - 200

Residual pressure in the circuit bar - 0.25

Expansion tank pressure bar - 1

Maximum pressure in the circuit bar - 3

Expansion tank volume l - 8

Water temperature in the heating circuit, not more / not less than ° C - 85 / 35

Water temperature in the DHW circuit, not more / not less than °C - 60 / 36

Flow rate in the DHW circuit (after 10 min at dT=30 °C) l/min - 11.3

Flow rate in the DHW circuit at dT=25 °C l/min - 13.6

Flow in the DHW circuit at dT=35 °C l/min - 9.7

Water consumption in the DHW circuit, not less than l / min - 1.7

Pressure in the DHW circuit, no more than bar - 7

Voltage and frequency V/Hz - 230/50

Power consumption W - 92

Protection class °C +5

Weight kg - 30

Dimensions (W x H x D) mm - 400/770/315

Commissioning of the gas boiler Ariston BS ii 24 ff

To turn on the boiler, press the on/off button on the control panel.

Power supply - Make sure that the voltage and frequency in the power supply network correspond to those indicated on the nameplate of the wall-mounted boiler Ariston BS 24 ff.

Gas supply:

Make sure that the type of gas in the system corresponds to that indicated on the boiler nameplate.

Open windows and doors.

Make sure there are no open flames or sources of sparks.

Check the gas burner part of the gas wall-mounted boiler Ariston BS ii 24 ff for leaks. To do this, with the gas supply valve closed (switched off), close and reopen the main gas valve. Within 10 minutes, the meter should not register gas flow.

Filling the heating circuit:

Open the air valves on the radiators of the heating circuit.

Raise the cap of the automatic air vent of the circulation pump.

Gradually open the boiler feed valve and close the air valves on the radiators of the heating circuit until water starts to come out.

When the pressure according to the pressure gauge reaches 0.1 - 0.15 MPa (1 - 1.5 bar), turn off the boiler feed valve.

First commissioning

Make sure that:

The main gas valve is closed.

Electrical connections completed. Check again that the green (yellow) wire is connected to a good ground.

Lift the cap of the automatic air vent of the circulation pump with a screwdriver.

Make sure that the pressure in the system (as indicated by the manometer) is greater than 1 bar.

Turn on the column (by pressing the on / off button) and select the stand-by mode, there is no request for either domestic hot water or the heating system.

Start the venting cycle by pressing the MODE button for 10 seconds. The column will begin an evacuation cycle of approximately 7 minutes.

At the end, check whether the air is completely removed from the heating circuit, if not, repeat the cycle.

Bleed air from radiators.

Open the cold water supply valve, wait until the air is completely removed from the circuit.

The chimney must be properly sized and free of obstructions for the removal of combustion products.

Make sure that the necessary ventilation holes in the room are open (they should be in a type B installation).

Open the gas valve, check all seals for tightness: the meter should not show gas flow. Repair if there are leaks.

Start the Ariston BS 24 ff boiler in winter (heating) or summer (DHW) operating mode.

Automatic forced air removal mode

To start the mode, press and hold the MODE button for 10 s. The duration of the cycle is approximately 7 minutes.

To interrupt the cycle, press the MODE button. If necessary, the cycle can be restarted.

First make sure that the boiler is in standby mode, i.e. without supply to the DHW and heating circuits.

Checking gas parameters

Remove the front decorative panel and lower the control panel of the Ariston BS ii 24 ff boiler.

Inlet pressure check:

Loosen the screw and insert the pressure gauge connection tube into the pressure tap.

Start the boiler at maximum power in the “Chimney sweep” mode (press the RESET button and hold for 10 s, the display in position 27 shows “L- -“). The gas inlet pressure must correspond to the nominal for this type of gas.

After 10 minutes or by pressing the button again, the boiler exits the "Chimney sweep" mode.

Checking the maximum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the maximum power, loosen the screw and connect the manometer tube to the pressure tap.

Start the boiler in the “Chimney sweep” mode: press the RESET button and hold for 10 s, the display shows “L- - “; for the boiler to operate at maximum DHW output, press the 1 + button. The display shows “L- - “.

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, remove the protective cap and tighten or loosen the adjusting screw.

After checking, tighten the screw and make sure it is tight.

Replace the protective cap of the regulator.

The boiler exits the "Chimney sweep" mode automatically after 10 minutes or immediately by pressing the RESET button.

Checking the minimum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the minimum power, loosen the screw and connect the manometer tube to the pressure tap.

Disconnect the combustion chamber compensator tube.

Start the boiler in the "Chimney sweep" mode: press the RESET button and hold for 10 s. The display shows "t". To make the boiler work at minimum power, press button 1 +.

The display shows "L- - ".

Disconnect the wire from the pressure regulator (modulator).

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, adjust it with a screw.

After checking, tighten the screw and make sure it is tight.

Connect the wire to the pressure regulator.

Connect the compensator tube.

The Ariston BS ii 24 ff boiler exits the “Chimney sweep” mode after 10 minutes automatically or immediately by pressing the RESET button.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Gas boilers Ariston appeared on the Russian heating market among the first. Largely due to its world-famous brand, this Italian manufacturer of gas heating equipment quickly managed to "win" the domestic buyer and achieve high sales dynamics.

Ariston gas boiler, reviews of the owners of which help to better decide on a purchase, we can often find on different sites and in online stores. A modern set of functions and good design, good technical characteristics and a large selection of models are a clear advantage when buying a device, even despite the somewhat inflated prices.

But today we will consider not only the pros, but also the disadvantages of Ariston mounted boilers, having studied their device and features of the models, using the instruction manual, photos, customer and specialist reviews.

Model range of wall-mounted double-circuit gas boilers Ariston

The Italian manufacturer is represented on the Russian market by a fairly wide range of wall-mounted gas boilers. We can meet Ariston double-circuit and single-circuit gas boilers, traditional and condensing, with and without a storage boiler.

In addition, like most competitors, Ariston gas heating boilers are available with a closed combustion chamber (turbocharged) and open (atmospheric). For devices with forced draft, a chimney outlet is provided horizontally through the wall, additionally buying a special one for it with a pipe diameter of 60/100 mm.

Gas boilers Ariston: product range


To date, the Italian company produces several modifications of its traditional double-circuit gas boilers:

- Ariston BS 15 FF, 24 FF and 24 II;

- Ariston Cares X 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston HS 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston Clas X 24 FF, 28 FF and 24 CF;

- Ariston Egis Plus and Premium;

— Ariston Genus X;

— Ariston Alteas X.

The single-circuit gas boiler Ariston with the possibility of connecting an indirect heating boiler is represented by only one model “Ariston Cares X System” with a power of 15 to 32 kW with closed and open combustion chambers.

Double-circuit gas boilers Ariston are available with a capacity of 15, 18, 24 and 28 kW. The most popular modification is a 24 kW device that can heat a house up to 200-230 m2. Turbocharged boilers have the symbols FF in their name, atmospheric - CF.

Features of the Ariston Cares X gas boiler: instructions, device

Ariston Cares X 24FF


This model is one of the budget ones in the price segment up to 35,000 rubles, and due to this, the most popular, judging by the number of reviews from the owners of the Ariston boiler. But even for a small amount, the buyer receives a modern wall-mounted gas boiler that has a nice appearance, button control and an LCD display, as well as a whole range of necessary functions.

As on all models of Ariston wall-mounted gas boilers, the Cares X series devices are equipped with: Wilo with automatic air vent and gas valve SIT. In addition, they are equipped with a boiler safety group and a membrane expansion tank of 8 liters.

The gas boiler "Ariston Cares X" has two heat exchangers: the main copper with aluminum coating for the heating circuit and the compact secondary stainless steel for the DHW circuit. The capacity of this secondary heat exchanger for the 24 kW Ariston Cares X 24 FF (CF) models is 13.6 l/min. Consider the device of a double-circuit gas boiler Ariston Cares X 24 FF NG:

Double-circuit gas boiler Ariston


1 - outlet for a coaxial chimney;
2 - pneumatic relay;
3 - collector for condensate;
4 - main heat exchanger for heating;
6 and 19 - temperature sensors at the inlet and outlet of the heating circuit;
7 - Polidoro gas burner;
8 - ignition electrodes;
9 - secondary heat exchanger for hot water supply;
10 - gas valve SIT;
11 - safety valve 3 bar;
12 - ignition block;
13 - pressure gauge;
14 - tap for feeding the heating system;
15 - filter;
16 - DHW flow sensor;
17 - Wilo circulation pump;
18 - pressure switch;
20 - three-way valve drive;
21 - burner flame control sensor;
22 - combustion chamber;
23 - expansion tank;
24 - fan (turbine).

The "winter-summer" mode and room thermostat help to reduce gas costs. In summer, the boiler can only work on the DHW circuit, while in winter the device works economically thanks to the modulating gas burner. The room thermostat is not included in the boiler, but it can always be purchased separately.

Boilers of this series have in their device temperature sensors installed on the "supply" and "return", running water temperatures, flame and draft control sensors. In addition, the devices are equipped with a security system: protection against low water pressure, protection against freezing of the system and its overheating.

The Ariston gas boiler is adapted to Russian conditions, such as power surges, low gas pressure and low air temperature outside the window. But, even despite this, the manufacturer himself recommends connecting the boiler through.

This recommendation applies not only to boilers of this brand, but also to other wall-mounted gas boilers of any manufacturer. If the electronic board of the boiler suddenly fails due to a power surge, then this case will not be guaranteed.

Technical characteristics of the double-circuit gas boiler Ariston Cares X

Ariston gas boiler: technical specifications


Advantages of Ariston gas boilers:

- a very large selection of models;
- a prestigious global brand;
- Italian assembly;
- two heat exchangers;
— adaptation to Russian conditions.

Disadvantages of gas boilers Ariston:

- overcharge;
- components made in China;
- the main direction of the company is the production of storage water heaters.

Dual circuit gas boilers Ariston

The Ariston trademark, under which high-quality household and, in particular, heating equipment is produced, is today the property of the Italian concern Indesit Company. This brand combines the proven traditions of the past with the innovations of the future. All this makes Ariston appliances the perfect solution to ensure maximum comfort in your home.

Currently, the production divisions of Ariston and Hotpoint are combined into one functional structure. The result is a joint trademark, which is steadily gaining momentum in popularity both in Europe and in Russia.

A special place of honor among the assortment of Hotpoint-Ariston is occupied by water-heating boilers, which, perhaps, are the pride of the Italian company. Units supplied to the world market are distinguished by ergonomics and stylish design. It would seem, how can you make an ordinary design not only functional, but also visually attractive? Italian engineers from Hotpoint-Ariston were able to do this.

The undoubted advantage of Hotpoint-Ariston boilers can also be considered that they are distinguished by a high level of safety and ease of daily operation. They are also distinguished from competitors by their quiet operation, which is also very important, especially when installing heating equipment in a small apartment, where every sound can cause discomfort.

Hotpoint-Ariston designers strive to diversify the appearance of the proposed structures as much as possible, so that the buyer has the opportunity to choose exactly the model that harmoniously fits into the concept of a particular interior. Now it is not at all necessary to hide the water heating unit in a specially designated place, since the Hotpoint-Ariston boiler looks very stylish and concise.

The technique of the Italian brand is a unique combination of elegance, reliability and manufacturability. An important plus of Hotpoint-Ariston boilers is their environmental safety. And although this quality is not valued by the Russian consumer as highly as by the European, the loyal attitude towards the environment confirms the manufacturer's desire for continuous improvement of each unit of the model range.



Ariston has a lot of achievements in its long history. Founded in the 1930s as a family business, today it can safely be called one of the leaders in its industry. Today, products offered under the Ariston brand rank third in their market segment in terms of sales. The main activity of this functional division of Indesit is the production of household appliances of the middle and high price segment.

If we talk about heating equipment offered on the domestic market under the Hotpoint-Ariston brand, then first of all it is worth mentioning BS type water heating boilers. It is this technique that is in deserved demand all over the world, due to its efficiency and performance. At the same time, each of the models in the BS line has small dimensions and weight, which greatly facilitates the process of their transportation and installation. An obvious plus of these heating boilers is also that they are equipped with separate heat exchangers. Separately, it is worth mentioning the reliability of the built-in hydraulics, which can withstand aggressive operating conditions without any problems.

Let us consider in more detail the most popular modification of equipment in this line - the boiler Ariston bs 24 ff

The gas boiler Ariston bs 24 ff is a high-performance wall-mounted 2-circuit type unit that can be used simultaneously for hot water and heating. Among the proposals on the market, this equipment can be considered the most attractive, since it combines technical excellence, durability and affordable price.

Experts recommend installing Ariston bs 24 ff as a universal means for heating apartments and private residential buildings. This technique makes it possible to significantly reduce the cost of the family budget for heating, when compared with the central water supply system. By purchasing an Ariston bs 24 ff boiler, you can forget about the cold weather even at unusually low temperatures outside the window. Italian brand equipment is able to maintain comfort in your home at all times.

Among the advantages of the Ariston bs 24 ff model, the following are worth noting:

  • Adaptability to work in difficult Russian conditions. The technique easily copes with lowering the gas pressure in the system to a level of 5 mbar. In addition, the boiler continues to function even with water pressure drops in the circuit, which is also very important for our country. Ariston bs 24 ff is adapted to power surges due to the presence of a special protection system.
  • The boiler is able to maintain operation even at very low temperatures outside the window (up to -52 degrees Celsius).
  • The presence of an analog control panel, which displays the temperature of the coolant in the system.
  • The possibility of distributing the intensity of the heating system without affecting the water heating system.
  • Electronic flame modulation.
  • Protection of the boiler against scale.
  • Pump blocking prevention system.
  • Prevention of freezing of the coolant in the system in case of a decrease in the air temperature outside the window.
  • Ariston bs 24 ff is able to independently diagnose a problem and adequately respond to its occurrence.

The Ariston boiler will please the buyer with the presence of a copper heat exchanger and a secondary plate heat exchanger made of stainless steel. The specialists of the manufacturing company took care of the durability of the equipment, equipping it with a durable stainless steel burner that can maintain stable operation for decades.

As additional structural advantages, it is worth noting the elements of the hydraulic system made of durable materials, a 3-way valve with a drive, two temperature sensors and two filters for mechanical cleaning of the coolant.

Ariston bs II 24 ff

Ariston bs II 24 ff is a reliable 2-circuit wall-mounted gas boiler with a closed firebox. A separate heat exchanger increases the efficiency of the entire system and extends the life of the equipment. The useful power of this unit is 25 kW, which is enough to heat an apartment or a small country house, the area of ​​\u200b\u200bwhich does not exceed 240 square meters. At the same time, the maximum temperature of the coolant in the heating system reaches 85 degrees Celsius.

The equipment is highly productive. Ariston bs II 24 ff is capable of producing 13.6 liters of hot water per minute at a temperature of 25 degrees. And the efficiency reaches 93%. For this class of equipment, such a high efficiency is a worthy indicator.

The device is easy to install, so it is not necessary to entrust this task to specialists. If you are confident in your own skills and want to mount Ariston bs 24 ff on your own with the instructions that come with the equipment, you can easily do it.

But do not forget that an experienced specialist with one hundred percent probability will be able to install the equipment without any errors, which will protect you from the possible withdrawal of equipment from warranty service, which the manufacturer has every right to do in case of violation of any standards. The instructions for Ariston bs 24 ff are clear and comprehensive enough for the wizard to cope with the installation without problems.