Electric boilers evan epo 4 electric circuit. Before turning on the electric boiler, make sure that

There is no external remote control in it, since it is not needed. The temperature regulator is located on the boiler itself, in the upper end part on the heating element. The electric boiler is equipped with a cable and an euro plug, the power consumed is 220 V. It is very easy to install this device in the electrical network. It is well applicable in country houses, boxes, small garages where a high temperature in the room is not particularly needed. Another of the more frequent applications is to work in "pair" with another heat generator, such as solid fuel. At night, it turns on to maintain the temperature of the coolant in the system. The heating element is made of high quality stainless steel. The ability to control the temperature within 35-80 degrees, a connector for connecting the pump.
The boiler has been tested at the EVAN CJSC plant, certified, and has a 12-month warranty.

Buy boiler EVAN in Moscow.

You can buy an electric boiler in our store in Moscow. It is also possible to deliver the ordered equipment to all regions of Russia using the services of the most convenient transport company for you.

Electric boiler EVAN EPO 4 kW. Heated area: 40 m2. The price is for the boiler complete with 1-stage control panel.

Electric boiler EVAN EPO 4 is a stationary electric heater designed for heating residential, domestic, industrial and other premises.

All models of electric boilers EVAN EPO

More

More

BUY Electric boiler EVAN EPO-4 (4.0 kW) for 7267.5 rubles

More

BUY Electric boiler EVAN EPO-6 (6.0 kW) for 9337.5 rubles

More

BUY Electric boiler EVAN EPO-7.5 / 220B (7.5 kW) for 11520 rubles

More

BUY Electric boiler EVAN EPO-7.5 / 380B (7.5 kW) for 11520 rubles

More

BUY Electric boiler EVAN EPO-9.45, (9.45 kW), 380V for 12577.5 rubles

More

BUY Electric boiler EVAN EPO-12, (12.0 kW) for 13297.5 rubles

More

BUY Electric boiler EVAN EPO-15 (15.0 kW) for 15270 rubles

More

BUY Electric boiler EVAN EPO-18, (18.0 kW) for 16875 rubles

More

BUY Electric boiler EVAN EPO-24 (24.0 kW) for 17460 rubles

More

BUY Electric boiler EVAN EPO-30, (30.0 kW) for 22987.5 rubles

Application should be considered in the following cases:

As the main source of heat (if there is sufficient allocated electric power and if it is impossible (or expensive) to connect to the gas distribution network;
- as a temporary source of heat for the period of construction work and laying of engineering communications;
- as a backup or additional source of heat during emergencies;

Installing an electric boiler as the main or additional source of heat in an existing or planned water heating system is not particularly difficult and, as a rule, does not require complex additional measures (for example, chimneys, foundations, window openings), subject to a qualified connection in compliance with electrical safety requirements.
For preliminary selection of the required power of the electric boiler, one can proceed from the calculation of 1 kW per 10 m2 of heated area. In rooms that meet modern requirements for heat loss, the specific electrical power can be significantly lower.
A wide power range of EVAN EPO electric boilers from 2.5 to 480 kW allows solving the problems of heating both a small country house and a residential building or production facility with an area of ​​​​up to 4800 or more m2.
Electric heating boilers EVAN EPO 4 can operate in heating systems with natural and pump circulation. Both water and non-freezing liquid can be used as a heat carrier. EVAN recommends DIXIS antifreeze for use.

Technical characteristics of the electric boiler EVAN EPO 4 kW

Electrical power: 4.0 kW
- Possibility of smooth regulation of the heat carrier temperature in the range of 30-85°С
- Efficiency of the device, not less than 93%
- Double protection against overheating
- Operating pressure in the boiler, not more than 0.3 MPa (3.0 atm)
- Test pressure of the boiler in production 0.5 MPa (5.0 atm)
- Crimping pressure of the heating system with the boiler after installation, no more than 0.4 MPa (4.0 atm)
- Response temperature of the emergency sensor with self-return 92±3°C
- Heating elements are made of stainless steel
- Light indication of work
- Reliable operation when the mains voltage changes ±10% of the nominal value
- Warranty period of operation 18 months

Technical description of electric boilers EVAN EPO 4 kW

1 - body
2 - protective cover
3 - heater
4 - cover
5 - emergency thermal switch with self-reset, thermostat sensor a
6 - outlet pipe
7 - inlet pipe
8 - thermostat sensor a (not visible)
9 - clamp M8 for zero protective conductor PE

Dimensions and weight of the electric boiler EVAN EPO 4 kW

Height: 565 mm
Case Diameter: 159 mm
Cap diameter: 220mm
Length with connecting pipes: 270 mm
Connecting size of branch pipes: G 1¼"
Weight: 15 kg

Overall dimensions of the EVAN EPO console (height x width x depth) and weight:

1-stage 4-18 kW - 270x205x175 mm, Weight 3 kg
1-stage 24-30 kW - 280x205x175 mm, Weight 4 kg
3-stage 4-30 kW - 265x380x180 mm, Weight 6 kg

Specifications EVAN EPO 4 kW

Supply voltage: 220 V
Heated area, m 2: 40
Cross section of the power cable core (copper), mm 2: 4,0

The design of EVAN electric boilers provides for the choice of the desired temperature regime, depending on the air temperature in the room. To do this, the boiler control panels are equipped with a connector "Connector X1" for connecting a room thermostat. When using an air temperature sensor, the control circuit will automatically switch to work with this sensor. To do this, the "Temperature" knob on the boiler control panel must be brought to the maximum temperature mark and all power levels must be turned on. Further, the switching on and off of the electric boiler to maintain the temperature set by the room thermostat will occur automatically.

When choosing a room thermostat, it must be taken into account that it must contain a changeover contact. The connection of the room thermostat to the boiler must be made with a two-wire cable with a cross section of 0.5 mm 2.
EVAN EPO boilers are switched off when the sensor contacts are closed.

Thermostats (with built-in air temperature sensor) for controlling EVAN boilers:

Electric boiler EVAN EPO-4 (4.0 kW), diagram and connection procedure.


The electric boiler EVAN EPO-4 (4.0 kW) is operated with a protection device installed in the stationary wiring. Before trial switching on the boiler after connection, maintenance and (or) repair, make sure that the device has a zero protective conductor PE.

Before turning on the electric boiler, make sure that:

The absence of a break in the visible part of the zero protective conductor;

The absence of damage to the visible part of the insulation of the electrical wiring and the zero protective conductor PE;

The absence of visible leaks of the coolant from the device and the heating system;

The absence of a frozen coolant in the heating system;

The presence of coolant in the expansion tank.

Start-up and adjustment works include:

Connecting the boiler to the electrical network;

Filling the system with coolant;

Removal of air from the heating system;

Bringing the pressure to normal in accordance with the requirements of this instruction manual (when using an expander);

Trial run;

Adjustment of the system and valves;

Before installing the boiler, check the correctness and quality of the installation of the heating system with natural circulation.
The pipes of the heating system must be located so as to promote the natural circulation of the coolant. In this case, the maximum level of the coolant should not exceed 30 meters to the level of the boiler (the working pressure in the boiler is not higher than 0.3 MPa).
If it is impossible or undesirable to achieve natural circulation of the coolant in the heating system, a circulation pump must be used.
The heating system must necessarily have an expansion tank that communicates with the atmosphere. When using a membrane-type expansion tank, a safety valve designed for a pressure of not more than 0.4 MPa must be installed before the ball valve at the outlet of the boiler.
Since when the safety valve is triggered, coolant or steam can be released through its drain hole, it is necessary to connect a drain to the sewer system to it.
Ball valves are installed at the inlet and outlet of the boiler, which are used during dismantling, repair and maintenance of the device.

The installation of shut-off valves on the pipeline connecting the expansion tank to the heating system is prohibited!

Pressurization pressure of the heating system with the boiler after installation - no more than 0.4 MPa.
The boiler must be mounted in a vertical position.
The control panel is mounted vertically at a height of 1.4-1.7 m from the floor on walls and structures in well-lit rooms.

Electric boilers of various classes, similar in electric power:

More

BUY Electric boiler EVAN EPO-2.5 (2.5 kW) for 6262.5 rubles

More

Electric boiler EPO class 4 "Standard-Economy" is the most budgetary model in the range of EVAN heating devices, which is suitable for use both at home and in the country. A 20% reduction in the price of the device, in contrast to the “Standard” class following it, is achieved due to the absence of a housing that combines the boiler and the control panel, while maintaining all the basic characteristics and capabilities. The required temperature of the heat carrier in the boiler is set by the built-in thermostat by smooth adjustment from 30 to 85 degrees. In addition, the boilers have the ability to connect an external thermostat, with which you can adjust the air temperature in the room. The GSM-Climate boiler remote control module (except for EPO-2.5) can be used as an external thermostat, which allows you to control the temperature in the room from a distance, control the operation of the boiler and monitor its serviceability. To ensure safety when heating to the set temperature of the coolant, the thermostat turns off the boiler and turns it on again after the temperature drops below the set one. For additional protection against overheating, the devices are equipped with a self-resetting emergency thermal switch, which, in the event of a failure of the main thermostat, turns off the boiler when the coolant reaches a temperature of 92 degrees. The heating elements of the EPO 4 boiler, like all EVAN electric boilers without exception, are made of stainless steel, which increases their service life.

Specifications

Power supply, V 220 Electrical insulation class I Width, cm 16 Depth, cm 20 Height, cm 50.5 Efficiency, % 99 Heating temperature range, C 30-85 Heating connection 1 1/4" (DN32) Power consumption, kW 4.2 Power regulation single stage Max. heating pressure, bar 3 Appearance and equipment may be changed by the manufacturer without special notice.

EVAN NOVATOR is a practical representative of Comfort class electric boilers, which has wide functionality, allowing it to be used as a mini-boiler room. The EVAN NOVATOR electric boiler is ready for operation immediately after being connected to the heating system.

EVAN NOVATOR, as a representative of the intelligent generation of EVAN boilers, has a self-diagnosis system, which allows you to get information about the operating, service and emergency modes of operation of the equipment. Despite the impressive list of built-in components, the electric boiler is a compact, neat and silent electric heater. Like all intelligent generation boilers.

TECHNICAL CHARACTERISTICS OF ELECTRIC BOILER EVAN NOVATOR 4 kW

Model EVAN NOVATOR 4
Power 4 kW
Voltage 220V / 380V
heating elements heating elements made of high quality stainless steel
Power steps 2/2 kW when connected to 220V
1.33/1.33/1.33 kW when connected to 380V
Switching unit provides automatic selection of the power of the device and the temperature of the coolant supply
without jumps, the seven-storey type of load on / off (heating elements) guarantees noiseless operation
Heated area 40-60 sq. m
efficiency 99%

CHARACTERISTICS OF ACCESSORIES

Built-in circulation pump Wilo RS 15/5 Cast iron housing and stainless steel shaft provide a sufficiently high reliability of the pump.
This model allows you to set one of three options for rotation speed.
The choice is made depending on the design of the heating system and the type of coolant used.
Expansion tank Volume 6 l (closed type)
Automatic air vent there is

SECURITY COMPLEX

Pressure meter controls pressure in the range from 0.01 to 0.6 MPa
overheat protection self-resetting thermal switch turns off heating when exceeding
coolant temperature over 92°C
Protection against power surges and network power control of the presence of phases, automatic switching in case of loss of a phase to
remaining with the subsequent restoration of the uniformity of resource consumption.
Misconnection protection
Working on an unstable network
Emergency shutdown of heating Controller-independent heating shutdown

COMFORT AND CONTROL

Seven-account control type Seven-storer type working power control ensures automatic selection
device power and coolant supply temperature without jumps
Working on an unstable network stable operation at reduced (160V) and increased (260V) voltage
Graphic display Graphic display with intuitive navigation through settings and operating modes
Remote control the ability to connect remote control modules (GSM / Wi-Fi Climate)
DHW management hot water control - switching the valve that directs the flow of the coolant
to an indirect water heater (purchased separately)

QUALITY OF COMPONENTS, SERVICE

fault self-diagnosis, high maintainability

TECHNICAL DOCUMENTATION FOR THE BOILER EVAN NOVATOR 4

EVAN NOVATOR 4 ELECTRIC BOILER DEVICE

1 - rear panel
2 - inlet combined branch pipe, external thread G3/4
3 - circulation pump
4 - pipelines
5 - heat exchange capacity
6 - heater blocks
7 - top outlet with G3/4 external thread.
8 - membrane-type pneumohydraulic accumulator (expansomat)
9 - temperature sensor
10 - pressure sensor
11 - self-resetting thermal switch
12 - contactor coil
13 - power boards
14 - installation panel
15 - central board
16 - phase switch board
17 - screw cable clamps

18 - bolt clamp (ZBS)


In suburban villages, where the voltage in the network is often unstable, an electric boiler EVAN Novator will confidently work at reduced (from 160V) and increased (up to 260V) voltage. Intelligent circuit solutions of the phase switch guarantee the stability of operation in case of loss of 1 or even 2 phases. The device constantly determines and selects the phase that is best for the operation of the electric boiler.

  • Product description

    Electric boiler EPO class 4 "Standard-Economy" is the most budgetary model in the range of EVAN heating devices, which is suitable for use both at home and in the country. A 20% reduction in the price of the device, in contrast to the “Standard” class following it, is achieved due to the absence of a housing that combines the boiler and the control panel, while maintaining all the basic characteristics and capabilities.

    The required temperature of the heat carrier in the boiler is set by the built-in thermostat by smooth adjustment from 30 to 85 degrees. In addition, the boilers have the ability to connect an external thermostat, with which you can adjust the air temperature in the room. The GSM-Climate boiler remote control module (except for EPO-2.5) can be used as an external thermostat, which allows you to control the temperature in the room from a distance, control the operation of the boiler and monitor its serviceability.