Solid fuel boilers Teplodar Kupper - technical characteristics of the models. Universal heating boiler "Cooper" - types and features Transfer of goods to a branch of a transport company

Solid fuel combined boilers Cooper from the Novosibirsk company Teplodar a few years ago literally “blew up” the heating equipment market. All this is quite understandable. Before the advent of these universal Kupper boilers, buyers were offered either expensive imported options or unsightly domestic counterparts with a “soviet” design.

Quite a wide range of models, price, nice appearance and good build quality have done their job. A lot of information about them has already appeared on the Internet, and it is the universal Cooper boilers that have only positive reviews from the owners, including from the experts themselves.

Let's take a look at these water heaters, consider the model range, technical characteristics, device, as well as the advantages and disadvantages of combined solid fuel boilers of the Kupper brand.

The lineup

Cooper boilers are available in six main modifications:

1. Cooper OVK-10
2. Cooper OK-15
3. Cooper OVK-18
4. Cooper OK-20
5. Cooper OK-30
6. Cooper OK-42

What do all these letters and numbers in the marking mean?
The letters OK are a heating boiler, HVAC is a heating boiler with a hob (stove) for cooking. The numbers indicate the thermal power of this particular model. In OVK-10 boilers, fuel can be loaded directly from above, after removing the cooking stove from it.

Models OVK-10, OK-15, OVK-18, OK-20, OK-30


Cooper boilers are available in different capacities from 10 to 42 kW. The smallest boiler OVK-10 is able to heat a house up to 100 square meters, the most powerful OK-42 up to 400 meters.

In addition to the main modifications, Teplodar produces a series of boilers Cooper 22 Pro, Cooper Pro 28, Cooper Pro 36 and Cooper 42 Pro. These are universal, they are distinguished by a larger volume of the loading chamber, which increases the operating time from one firewood bookmark to another up to eight hours. These models have an additional chamber for afterburning gases produced by wood during its smoldering.

The device of universal boilers Cooper

The device and wiring diagram of the boiler Cooper


Boilers of this series consist of:

- steel case 3 mm thick;
- tubular multi-row heat exchanger;
— solid fuel loading chambers;
- kindling chamber;
- a layer over the entire volume of the boiler for its better thermal insulation;
- a box for collecting ash;
- thermometer;
- an internal fitting for installing a block of heating elements.

The principle of operation of the boiler

Solid fuel is placed through the loading door: firewood, coal or peat in briquettes. In the lower chamber you make kindling. When the fuel burns, heat is released, which heats the water in the heat exchanger (water jacket).

The heated coolant moves through the heating system either naturally or with the help of a circulation pump installed on the return pipe of the system. Exhaust flue gases are discharged through the boiler pipe into the chimney. The diameter of the flue pipe of these boilers is 150 mm, and for the OVK-10 model it is 120 mm.

The efficiency of heating the coolant in this wood-burning boiler was made possible thanks to a multi-row heat exchanger with pipes arranged in a checkerboard pattern. Water passes inside the boiler through the pipes of the heat exchanger without stagnation in it. On top of that, excellent thermal insulation with basalt significantly increases the efficiency of a solid fuel boiler.

Kupper boilers with and without hob


Operation of a boiler with a thermostat in long-term burning mode

In order for the device to work in an economical mode, it is necessary to purchase a special thermostat for the boiler. For it, a side threaded fitting is provided in the boiler body, where it is installed.

The thermostat comes with a chain, which must be connected at one end to the damper of the boiler’s ignition door, and at the other end directly to the thermostat.

There is a special temperature scale on the thermostat, setting the desired temperature, through the circuit and the door damper it regulates the air supply to the boiler furnace. Thus, the set temperature is maintained and our fuel is saved.

Judging by the reviews on Kupper boilers, when using this thermostat, the boiler can work on one firewood tab for up to 7-8 hours.

Boiler thermostat


Boiler operation on electricity, gas and pellets

All models of Kupper boilers are equipped with heating elements with a power of 6 kW. Models with a rated power of 30 kW or more - heating elements of 9 kW. This makes it possible to use the boiler not only on solid fuel, but also on electricity.

Of course, with the help of heating elements with a total capacity of 6 kW, it will be difficult to heat a house with an area of ​​​​more than 100 m2, but to maintain a certain temperature of the coolant, it is quite enough.

For convenient control of a group of boiler heating elements, it is possible to purchase a special control panel (CP) with temperature sensors for water and air. With its help it is very convenient to switch heating elements. You can, for example, turn on only 1 for 2 kW or 2 for 2 kW. True, the control panel is not included in the package, but you can buy it separately.

In addition, Cooper boilers can run on gas or pellets. To do this, it is possible to purchase a special automatic gas burner device (gas burner) AGG-13, -26, -40K with a capacity of 13, 26 or 40 kW, respectively, or APG-25 (-42).

Gas and pellet burners are installed in place of the boiler's ignition door. The door is removed and the necessary additional equipment cuts in instead of it.

Cooper boiler with gas burner


It should be noted that the gas consumption when using such a burner will be higher than that of a typical floor burner.

Thus, by purchasing a wood-burning boiler Cooper, you get a universal, combined boiler of the "wood-electricity" or "gas-electricity" type.

How to choose the right boiler of the Cooper OK series: technical specifications

If you need to heat a room of 100-120 sq. meters, it is better to buy a Kupper OK-15 boiler with a power of 15 kW. If cooking is also planned on the boiler, then you can choose the OVK-18 model with a capacity of 18 kW. And, for example, for a house of 200-250, we would recommend purchasing a boiler of the OK-36 model.

Remember the basic rule for selecting thermal equipment: 1 kW per 10 m2, and a small margin so as not to operate the boiler at the limit of its capabilities.

Technical characteristics of boilers Kupper


Advantages of solid fuel boilers Cooper

– versatility, the ability to use as fuel not only wood, coal, but also electricity, gas, pellets;
- good price-quality ratio (from 20,000 rubles);
- the possibility of cooking on certain models;
— original design and color of the paintwork;
- good thermal insulation.

Disadvantages of Cooper boilers

- new;
- a steel heat exchanger is less durable than;
- the absence of a thermostat for the boiler and a control panel for the heating element unit;
- there are no double-circuit models, all boilers are only single-circuit.

And finally, I recommend watching this video:

In this article, we have analyzed solid fuel combined boilers Cooper from the domestic company Teplodar. We considered the model range, internal and external devices, as well as advantages and some disadvantages. As you can see, our worthy competitor to imported heating equipment has appeared on the market. Let's hope that these boilers will live up to expectations and take their rightful place.

Universal boilers of the Kupper line are powerful single-circuit heating equipment in a compact design. Due to their efficiency and reliability, Kupper boilers have won the trust of the buyer and firmly occupy a leading position in sales.

Heating solid fuel boiler "KUPPER OK 15" is installed in rooms for various purposes with an area of ​​up to 150 m2. The boiler is built into any type of heating system.

The KUPPER OK 15 boiler runs on solid fuel - wood and coal. Thanks to the universal design of the KUPPER OK 15, it is easy to convert to work on gas or pellets using the installed Teplodar burners.

Features of the boiler "Kupper OK 15":

The staggered arrangement of the water-tube heat exchanger increases the flame travel, and the stainless steel flame deflector plate completely extinguishes the flame, which has a positive effect on efficiency.
The water tube heat exchanger improves heat removal and increases the efficiency of a standard water jacket.
The power of the boiler is regulated in the range from 30 to 100% by means of an installed automatic draft regulator.
The built-in 6 kW heating element maintains the temperature of the system after the completion of the combustion of the main fuel.
The kit includes accessories for cleaning the boiler, a rotary damper, a thermometer to control the temperature of the boiler.

ATTENTION! Chimney elements and draft regulator are not included in the kit and must be purchased separately.

Characteristics

Type of components Boiler

Type of fuel Solid fuel

Chimney diameter, mm 150

Firewood length, mm 310

Efficiency, % 78

Weight of the set, kg 98

power, kWt 15

Heated area, m2 150

Dimensions, mm 745 x 415 x 556

Write a review

Payment

Payment produced only in cash upon receipt of the goods upon self-delivery or to the courier upon delivery.

When buying any product for self-pickup or delivery by courier, cash and sales receipts are provided, as well as, if necessary, certificates.

Payment by non-cash- by agreement .

Pickup

Pickup is available for orders of any size. daily from 9:30 to 18:30 without breaks.

Self-delivery is carried out from a warehouse located at the intersection of 94 km of the Moscow Ring Road and the Yaroslavl Highway, the Trakt-Terminal Trade and Construction Complex, pavilion No. 5, place 26, (5/26).
See the map for directions "Contacts".

Delivery

For orders of any volume is available as a delivery service.

Delivery of most materials is carried out the next day.

Large orders are fulfilled during the week.

Delivery is carried out from a warehouse located at the intersection of 94 km of the Moscow Ring Road and the Yaroslavl Highway (Trakt-Terminal Trade and Construction Complex).
See location map in section "Contacts".

The cost of delivery is calculated individually based on the volume of the order and mileage.

Delivery within the Moscow Ring Road - 1200 rubles, then - 35 rubles / km. One way mileage calculation. For example, 20 km from Moscow Ring Road = 1200 + 20 km x 35 rubles. = 1900 r.

Delivery is carried out to the entrance. Rise to the floor, skidding into the house and other work are paid separately(by agreement). It is advisable to warn about the need for these works in advance in order to agree on the cost and the required number of loaders.

* - The estimated cost of delivery is calculated, the final cost is determined after receiving the goods at the company's terminal.

Professional installation and installation of stoves, fireplaces, chimneys

Installation of a fireplace stove and chimney is a very important and at the same time individual issue. For an accurate assessment of the labor intensity and cost of work, as well as the elements of the chimney and thermal insulation materials necessary for the installation, it is necessary for the master to visit the site directly. The installer of fireplace stoves will be able to see with his own eyes what he has to do, and the client can discuss all the nuances of the installation.

Why is it necessary to call a measurer to the object as the first step?

Solid fuel boilers Teplodar Kupper - technical characteristics of models

5 (100%) votes: 1

Today, the market for heating equipment presents a large number of different models produced by different manufacturers. Solid fuel boilers Kupper, manufactured by Teplodar, have won the trust of Russian users and are in great demand.

These units operate on,. In their design there is an electric heating element, some models can be equipped with a gas burner. Due to this, after the main fuel burns out, the temperature of the coolant in the system is maintained. User feedback on the operation of these units is very positive. In the article we will consider the distinctive features of these devices.

Heating boiler Teplodar Kupper OVK 10

Design features

The Kupper solid fuel boiler is made in a steel case, inside it there is a combustion chamber and an ash pan, around which there is a water jacket. In order for the efficiency of heat removal to be higher, at the very top of the heating solid fuel boiler Teplodar, the right and left sides of the heat exchanger are connected by transverse pipes, which are placed in a checkerboard pattern.

The space of the combustion chamber is separated from the pipes by means of a steel visor. The movement of flue gases towards the chimney does not occur directly, but bypassing the obstacle, giving even more energy to the coolant and increasing the performance of boiler equipment. In order to minimize heat loss, the hull is covered with balsam cardboard insulation, on top of which the hull panels are laid.

The principle of operation of all models is based on the transfer of heat to the coolant, which is formed during the combustion of fuel.

Boilers manufactured by Teplodar can be used in a piping scheme for a solid fuel boiler with natural / forced circulation. In order to make the connection of the unit to the supply and return lines as simple and convenient as possible, branch pipes are located on the right and left walls of the boiler.

Experts advise to connect only to the pipes on one side. If you connect the supply/return lines to opposite sides of the device, the heat exchange efficiency is reduced.

To be able to adjust the intensity of combustion, there is a damper at the very bottom of the body. By opening / closing it, you can adjust the supply of air masses to the combustion chamber. This procedure can be performed both manually and with the help of an automatic traction control. He is responsible for measuring the temperature in the heat exchanger, and, in accordance with the set parameters, adjusts the damper opening value. This process is carried out mechanically and does not require the presence of electrical power.

Pellet boiler Kupper can maintain a constant temperature in the system between bookmarks and coal or firewood, operating on electricity. To do this, each unit is equipped with heating elements, the power of which is 6-9 kW.

Advantages and disadvantages

Like any other type of heating equipment, Kupper wood-burning boilers have their pros and cons. When installing such devices, you will have to additionally buy a traction control sensor and a thermostat, and the fact that in some models the loading chamber is not large enough can also be noted as a disadvantage.

Most of the reviews indicate that pellet boilers Kupper OK 20, 15 are universal units that effectively cope with heating and note their advantages:

  • can operate on different energy carriers;
  • device performance is high;
  • units are easy to use and maintain;
  • power can be adjusted both manually and automatically;
    devices are easy to upgrade;
  • boilers are characterized by reliability and are made in accordance with European standards.

Models and Specifications

The domestic company Teplodar produces various models of Kupper boilers. Consider the most popular of them.

Boilers Kupper OK 15, 20, 30, operating on wood and coal

Kupper OK are traditional solid fuel units. In total, there are three sizes on the market with a capacity of 15, 20, 30 kW. Such devices can effectively heat rooms with an area of ​​​​150-300 m².

Solid fuel boiler Teplodar Cooper OK 15

Consider the technical characteristics of the Kupper OK boiler line

Kupper boilers with hob

This series is an improved previous one, it is designed from two devices for 10 and 18 kW. A key distinguishing feature is the hob, which provides the ability to cook food.

Technical indicators of Kupper HVAC models with a hob.

Pellet boiler Teplodar Kupper

This unit is a series of OK or OVK with a pellet burner APG 25 and a bunker with a control unit. During the operation of the device, in order to be able to burn fuel pellets, a prerequisite is the presence of electrical power. You can mount it directly on the boiler connected to the heating system.

Pellet boiler Kupper OK 20

Technical characteristics of boilers Kupper series OK or OVK.

Kupper boiler with gas burner

In order to transfer the functioning of the boiler from solid fuel to gas, it is necessary to resort to installing a gas burner AGG-13K or AGG 26K. In this case, OK and HVAC heating units will be an excellent option.

Technical characteristics of the Kupper OK and OVK models

Long burning boiler Kupper Pro

The Kupper Pro model appeared on the market in 2015 and in a short period of time managed to win the love and trust of users. This heater can operate on wood much longer than other models. This is due to new technical solutions that manufacturers have resorted to in the production of this equipment.

In addition to the standard water jacket and pipes located outside the combustion chamber, there is also a grate water-tube grate. This element contributes to higher heating efficiency. In addition, manufacturers have improved the supply of secondary air. The duration of burning on one load of fuel for Kupper boilers reaches 8 hours.

Solid fuel boiler Teplodar Kupper PRO 22

Technical characteristics of the boiler Kupper Pro

Kupper Comfort

This model is used to supply heat to rooms that are small in size and is available with a power rating of 10 kW. The boiler runs on wood fuel and has an enlarged firebox that allows you to burn long logs. Due to the original shape of the boiler unit, the coolant can move freely inside the heat exchanger, while stagnation zones will not appear. For convenience of operation the capacious ashpit is included in its package.

Technical characteristics of the solid fuel boiler Kupper Uyut 10

Summing up all of the above, it is worth noting that Kupper boilers manufactured by the Russian company Teplodar are highly efficient, high-quality units that can heat a house well.