Pass-through elements for Vilpe roof ventilation. Roof ventilation VILPE ​​Ventilation of sewer risers Vilpe

and the whole house. Properly selected and installed ventilation elements for residential and non-residential premises, plumbing units and under-roof space - a guarantee of comfort, healthy atmosphere and durability of your home.

In this article, we will describe in detail which ventilation elements are presented in our assortment, in what cases they are used and what tasks they solve.

Moisture is always present in roof structures: insulation and roof structure absorb it during the construction of the house; condensation forms on the bottom surface of the roofing material; while living in the house, moisture evaporates in the form of water vapor and enters the insulation and wooden structures; at heavy rain or snow and crosswinds, a small amount of water can get under the roofing material.

For moisture wicking and ventilation roofing system install ventilation elements. Their absence or ineffective work leads to the following consequences:

accumulation of moisture, the formation of condensate on the rafters and substructures, and subsequently mold and fungus that destroy wooden elements;

Corrosion of metal structures, destruction of brick and concrete parts;

Formation of frost on the roofing material and, as a result, damage to the roof and drainage system, the penetration of melt water under the roofing during thaws;

moistening of thermal insulation, leading to a sharp decrease in its efficiency and an increase in the cost of heating a house;

Overheating of the roofing material summer period(this is especially detrimental to bituminous coatings) and the interior of the attic;

Increase in air conditioning costs.

Under-roof space ventilation elements connect the under-roof space with outside air. Operating principle roof ventilation based on the use of differential pressure and air currents. Efficient ventilation requires air flow at the lowest point of the roof, that is, on the roof eaves, and roof fans ensure that this air is released into top point, for example, at the ridge or at the junction of the slopes to the walls, and effectively remove moisture.

Constant ventilation of the insulated roof structure is necessary condition long-term and reliable service of the entire building. The value of ventilation is difficult to overestimate - thanks to air flows, air is removed from the structure excess moisture, eliminates the likelihood of mold and fungi, the destruction of the wooden elements of the roof and insulation.

The choice of a roof fan depends on the type of roofing material; it can be installed both on a roof slope and on a ridge. In addition to under-roof space ventilation, roof fans are used for ventilation attic space. The required number of valves depends on the design of the roof.


Maintaining tightness is an important task that needs to be solved when bringing natural or forced ventilation and other elements.

Pass-through elements provide a hermetic passage through the roof, vertical installation of pipes on a slope and the operability of the ventilation system of internal premises, sewer risers, antennas and other elements. Pass-through elements are selected according to the diameter of the element brought to the roof and are mounted on almost any roof. Installation is quick and easy, without the use of sealing tapes, the service life of which can be significantly less time service roofing material, which further leads to leaks.

For hermetically leading cables and pipes of small diameters to the roof, e.g. inlet and outlet pipes solar battery, you can use SOLAR feed-through elements.


During the first years after construction, there is an active release of particles from building materials that accumulate in the air. Human activities and domestic animals also degrade air quality. Polluted and humid air that is not removed from the premises penetrates the structures, causing the growth of fungi and mold, and affects the well-being of a person.

To prevent this from happening, the house must "breathe", creating favorable conditions for the people who live in it. In accordance with sanitary standards, the air in the house must be completely replaced every two hours. This can only be achieved with the help of properly calculated and executed ventilation of the premises. The house should have an influx of fresh air, which is organized only in living and sleeping rooms. From these rooms do not make a hood. Ventilation allows you to direct the air flow in the house so that the air from the living and sleeping rooms flows into the premises with polluted and damp air and is removed from there. With such an organization, the air of the toilet, kitchen, bathroom, storerooms will not spread to the living rooms. To do this, exhaust valves are installed in the ceiling or walls of rooms with damp and dirty air and, with the help of air ducts, lead to the roof, where ventilation pipes with passage elements are installed.

The kitchen hood from the stove is displayed separately on the roof. It is not recommended to discharge it into a common duct, as grease contaminates the ducts, and unpleasant odors can spread throughout the living quarters.

Ventilation of rooms with gas equipment required according to the current building requirements SP 42-101-2003. The air from the boiler room is discharged to the roof separately using ventilation pipes with an internal diameter of 160 mm.

To avoid the appearance unpleasant odors, destruction of the sewer system due to the gases formed in the sewer, and the normal operation of the water seal, sewer risers must have a ventilation outlet to the roof. It equalizes the pressure in the system at the time of draining and removes the gases that destroy the pipes.


For sewer risers, it is recommended to use ventilation pipes with an internal diameter of 110 mm, which are thermally insulated and non-insulated. Uninsulated pipes are recommended for ventilation of sewer risers in regions with a mild climate. Thermally insulated ventilation pipes are recommended for ventilation of sewer risers in regions with a long frosty period. In an insulated pipe, no ice plug is formed that disrupts the ventilation of the riser. The ventilation pipe is connected to the sewer riser using a corrugated pipe with a diameter of 110 mm.

Forced ventilation performs the same functions as ventilation pipes, but much more efficiently.

Proper ventilation of the house involves the creation of low pressure in the house in relation to the environment. In this case, the walls and ceilings receive fresh air, and the structures are ventilated and dried - fungus and mold do not start in the walls.

Reduced pressure in the house is effectively achieved by forced ventilation.

Rubber seals and gates for pipes provide a hermetic output to the roof of antenna rods, pipes, cables, etc.

Seals available in several sizes various diameters pipes, there are one-piece and detachable. The latter are used to seal the joints of finished objects that cannot be sealed with one-piece seals. The flexible EPDM rubber seal allows for thermal and mechanical fluctuations, sealing the opening in the roof.


EPDM rubber is resistant to weather conditions and ultraviolet, well tolerates the effects of acids and alkalis contained in the air of industrial areas. Seals are installed directly on the roofing.

gate consist of an EPDM rubber seal in the upper part of the element and a plastic gate in the lower part, which is installed on standard passage elements, selected depending on the type of roofing material.


Pass-through elements PIIPPU are designed for hermetic output of round metal heat-insulated chimneys to the roof. The product is produced with a diameter of 200-265 mm or 280-380 mm, and can be installed on roofs made of metal tiles, flexible and natural tiles, suitable for seam roofing.

The PIIPPU feedthrough has passed fire tests in the Finnish VTT laboratory and has fire certificates.



7. Roof deflectors

Roof deflectors have the same purpose as roof fans - ventilation of the under-roof space and attic space. The installation of roof deflectors is recommended on roofs with a low pitch angle or in regions with large quantity snowfall, that is, in cases where the correct functioning of the roof fans is not possible. Deflectors are installed on roofs made of bituminous materials on the ridge of the roof or on the slope.


Moisture always accumulates in the basement of buildings, damaging building structures. The most efficient air circulation in the basement of the building is achieved with the simultaneous use of forced roof ventilation for the exhaust and the basement deflector as supply pipe. The forced fan is connected to plastic pipe, which is displayed in the basement.

Plinth ventilation can also be carried out in the system natural ventilation by installing an insulated ventilation pipe on the roof instead of a forced fan.

It is possible to ventilate the basement space using only basement deflectors.


For correct operation the ventilation system in the house must ensure the flow of air into the premises. For this, ventilation grilles or supply valves are used.


Supply valves provide filtration and supply of fresh air to the premises. The valve is equipped with a thermostat that is sensitive to temperature fluctuations. The air flow changes automatically depending on the change in the outside air temperature. The thermostat setting can be changed as needed. The valve has a filter that traps dust, pollen and the most dangerous mineral microparticles.

The roof hatch is a technical and fire hatch, used for access to the under-roof space or to the attic.


If you have any questions about the range of ventilation elements, their purchase or installation, please contact us in any convenient way or come to our customer service centers.

1.
2.
3.
4.
5.

The ventilation system, as you know, is an integral part of almost any building, be it residential, industrial or utility buildings. Thanks to good ventilation, the air in the premises of the building will be able to circulate in a normal rhythm, which, of course, is a very important factor. But in order to mount a good ventilation system, it is necessary to equip the node of the passage through the roof.

There are a lot of options for its arrangement, since the installation method depends, first of all, on the type of roofing device. Each roof has its own individual design features, therefore, the roofing passage unit has many construction schemes in accordance with the type of roof.

The need for arranging passage nodes

The main purpose of the roof passage elements is the removal of polluted and exhaust air. The design of such elements is carried out in accordance with GOST 15150, where the distances from the passage node to the edge of the slab are precisely determined, as well as the diameters of the holes that are located in the floor slabs. It is possible to equip passage nodes not only for, but also for chimney systems in those structures that are equipped with a fireplace or furnace heating. This method of device is sometimes referred to as roof penetration.


Based on the type of roof structure and the ventilation intended for it, the air duct passage through the roof may have the following forms:

  • square;
  • round;
  • oval;
  • rectangular, etc.

In their appearance, the nodes resemble holes made in the ceilings. Metal pipes are carried into these holes, which are mounted on the roof or on reinforced concrete cups. The thickness of the material used should not be less than 1 mm. Manufacturers produce ventilation units of various sizes, this applies to both their length and thickness. The type of ventilation system that serves as the connection point for the pipe can be either natural or forced.


Before finally making a decision in favor of one or another type, you should focus on such factors that can affect the choice, such as:

  • humidity indicators;
  • gas contamination coefficient;
  • the lowest and highest air temperature inside the building;
  • dust coefficient, etc.

The passage element for the roof is mounted using special reinforced concrete systems by fixing them to anchor bolts, which, in turn, are installed in the glasses during their construction.


The entire installation process depends on the following criteria:

  • the angle of inclination of the roof slope;
  • interval from penetration to roofing ridge;
  • roofing thickness;
  • the area that the space under the roof has.

In the event that the basis of the floor is reinforced concrete, then at the location it is necessary to use special slabs equipped with ready-made holes. If the diameter of this hole does not match the integrity of the slab, then places made of concrete in the form of a monolith are mounted in the installation area of ​​the penetration.

In this case, the passage through the roof with a light metal frame will be the same, but the glasses must be made of metal. A large building, which carries the functions of a residential, industrial or civil purpose, requires the calculation of the location of the roof passage units at the design stage.

Installation of ventilation, in detail on the video:

Installation of a pass-through unit for a chimney

Most often, the chimney pass-through device is carried out at the shortest distance from the roof ridge. With this installation option, the main part of the chimney pipe should be located under the base of the roof, which will protect the structure from condensation. However, there is another installation option, in which the installation of pipes is carried out through the roof ridge.

Arrangement of the chimney roof slope is fraught with the formation of a pocket of snow in the upper part of the pipe, which can cause leakage. Therefore, it is very important to use sealants for roof passages, as well as to design truss system which may lead to certain difficulties. However, it has its advantages, in particular - ease of installation and no risk of leakage.


It is also impossible to bypass fire-fighting measures by arranging passage nodes chimney through a wooden covering, as well as a roof, which should be protected from potential fire due to overheating of the pipe.

The chimney itself is recommended to be equipped with special umbrellas to prevent moisture and wind from entering it. The passage assembly should not be mounted in the valley area, since there is a possibility of poor sealing of roof joints and pipe apron. In addition, this area is particularly prone to the formation of ice and snow pockets on it.

Pitched roof requires a device wooden system rafters, which, as it becomes clear, has a maximum degree of combustion. That is why it is necessary to equip all the gaps between the pipe and wooden elements in accordance with building codes and rules (SNiP). To prevent contact of the heated pipe with combustible materials, a special design should be used. Usually for this necessary place a passage node in the form of a rectangle is mounted. In appearance, it resembles a box filled with glass wool or any other non-combustible material.

Roof penetration options

Today, manufacturers make the passage nodes of the most different types:

  • equipped with a valve;
  • without valves;
  • equipped with a heater;
  • without insulation;
  • equipped with technology that controls the opening and closing of valves.


Units that have manual control in their design are usually used where there is no need to regularly use multiple ventilation modes.

The manual assembly includes:

  • tailor's cloth;
  • counterweight;
  • cable;
  • management sector.

A special mechanism helps to control the valve, which regulates the position of the valve through two basic commands- "open" and "closed". To create penetrations for the roof, manufacturers use a black sheet of metal, the thickness of which does not exceed 2 millimeters, as well as a sheet of of stainless steel having a thickness of 0.5 to 0.8 mm.


The production of a passage unit can also be carried out on the basis of galvanized steel along with a heater, which is most often represented by a layer mineral wool 50 millimeters thick. This option involves a device in the system of umbrellas or deflectors treated with zinc. When mounted on a fan assembly, the internals may be perforated steel and fitted with electrically conductive plastic tubes. With this method of installation, the passage assembly will also perform a soundproof function.

Roof ventilation Vilpe (Vilpe) from Finland. Ventvyhody, aerators and pass-through elements Vilpe.

Vilpe ventilation elements

Roof aerators KTV

Ventilation outlets

Provide ventilation of the under-roof space and attic

They serve to bring ventilation of interior spaces through the roof

Antenna output

Pass-Through Elements

Designed for hermetic output through the roof of antennas and pipes from 12 to 90 mm

Used for mounting ventilation outlets on any roof

Roof aerators KTV (roof valves)

Roof aerators provide ventilation of the under-roof space and attic. Protect from rain and snow under the roof. Mounted on sloped pitched roofs.

Muotokate (Maxi) KTV

Classic KTV

Designed for installation on a metal roof

Aerator for a smooth roof (soft or seam)

Pelti KTV

Huopa KTV

soft flange through element fits snugly on any profile. The height of the roof profile should not exceed 38 mm.

Aerator for soft tiles, is placed during the installation of the roof

Ventilation outlets are used to bring ventilation of interior spaces through the roof. They reduce the air resistance at the outlet, thereby increasing traction. Caps with deflectors protect from rain and snow. Insulated versions have thermal insulation between the inner pipe and the outer one. The insulation layer protects against the appearance of an ice plug in the inner pipe due to freezing of condensate.

Sewer ventilation outlets

ventilation outlet sewer riser designed to ventilate the sewer system, equalize the pressure in the system and ensure the normal operation of the water seal. You can additionally order a corrugated pipe with an adapter 110/75 - it connects the ventilation outlet to the riser.

Caps Vilpe

Antenna output

Designed for installation of ventilation outlets on any roof. There are Vilpe passage elements for metal tiles, for smooth roofing and universal ones. Thanks to their ball joint, the ventilation outlet can be placed vertically on a roof slope with any angle of inclination.

Muotokate (Maxi)



Designed for metal tiles with a profile height of more than 38 mm

Universal passage element for roofing made of metal tiles, corrugated board, euro slate with a profile below 38mm


Passing element for soft tiles. Installed during roof installation

For folded and soft roofs. Installed on finished roof

Vilpe ventilation elements can be purchased in 6 colors:

  • brick RAL 8004
  • brown RR 32
  • red RAL 3009
  • green RR 11
  • gray RAL 7015
  • black RAL 9005.


For cottage construction, we offer sets of modern ventilation units VILPE-vent, including roof valves and fans, ventilation outlets air cleaners and sewers, fittings for drains, antenna outputs and rubber seals.

All VILPE ​​roofing accessories are made of impact-resistant, durable polypropylene that can easily withstand any weather and temperature conditions. Thanks to the diverse color scheme and thoughtful design, you can always choose VILPE ​​products to match the roofing material, which will make the appearance of your house truly beautiful and elegant. Hermetic adjoining on any roof is provided by special roof penetrations corresponding to the type of roof.

Advantages of Vilpe ventilation:

  • Simple and robust construction with thoughtful, harmonious design;
  • Resistance to ultraviolet rays and exposure to all types of weather.
  • Long service life due to the manufacture of high-quality material that is not subject to corrosion;
  • The ability to install vertically on roofs with any slope (including installation on finished roofs is possible);
  • Six standard colors are offered.

Colors of Vilpe ventilation elements

Vilpe feed-throughs


Price: 1 250 rub.

The MUOTOKATE pass-through element is designed for mounting on metal with a tiled profile of pipes and fans with a diameter of 110 - 160 mm, an antenna outlet and a seal heating boiler. Due to the flexible flange it is possible to install the feed-through element on almost any profile. The minimum length of a metal tile profile is 350 mm. Perfectly combined with metal tiles with Monterrey and Elite profiles. On the inside The flange is provided with a special rubber seal, which ensures the tightness of the installation. The size of the MUOTOKATE passage element is 330x260 mm. It is installed on the finished roof.


Price: 750 rub.

The HUOPA feedthrough is used for installation on soft roof pipes and fans with a diameter of 110 - 160 mm, an antenna outlet and a heating boiler seal. The dimensions of the element are 583x488 mm, it has a flange 150 mm wide. The installation of the HUOPA pass-through element is carried out when laying the roofing material.


Price: 1 150 rub.

The CLASSIC pass-through element is designed for mounting pipes and fans with a diameter of 110 - 160 mm, an antenna outlet and a heating boiler seal on a folded and finished soft roof. A rubber seal located on the inside of the flange guarantees complete tightness of the installation. The dimensions of the element are 351x266 mm. It is installed on an already finished roof.


Price: 4 250 rub.

PELTI

The PELTI pass-through element can be used to install pipes and fans with a diameter of 110 - 160 mm, an antenna outlet and a heating boiler seal on metal tiles. Special rubber compressor it is easily formed according to the profile of metal tiles due to the aluminum layer on the seal flange, which guarantees the tightness of the installation. Not applicable for metal tiles with a trapezoidal profile over 38 mm. The dimensions of the PELTI element are 355x460 mm. Installation is carried out directly when laying the roofing material.

Under-roof space ventilation Vilpe


Price: 1 000 rub.

Roof valve HUOPA-KTV is designed for ventilation of roof structures and attic space on pitched roofs made of soft roofing material. To ensure ventilation of roof structures, it is better to use a KTV valve without an adapter. In the attic room, a KTV valve with an adapter is recommended, which is connected to a pipe leading to this room.

In addition, the KTV roof valve with adapter can effectively ventilate the sewer riser in regions with warm winters. In this case, the corrugated pipe for connection to the sewer riser must be ordered separately. The dimensions of the passage element are 583x488 mm, the flange width is 150 mm. It is installed when laying roofing material.


Price: 1 150 rub.

The HUOPA - KTV / Harja roof valve is used to ensure effective ventilation of roof structures and attic space on pitched roofs made of soft roofing material. It is possible to install the valve on a roof slope or ridge and close to the wall. For ventilation of roof constructions we recommend the KTV valve without an adapter, for the attic room - KTV with an adapter. In the latter case, the adapter simply connects to the pipe leading to the attic.

Another area of ​​application KTV valve with adapter - ventilation of the sewer riser in regions with warm winters. In this case, a corrugated pipe for connection to a sewer riser will need to be ordered separately. The size of the passage element is 430x440 mm. Mounted when laying roofing material


Price: 2 000 rub.

The CLASSIC - KTV valve is designed to provide ventilation of roof structures and attic space on pitched roofs made of seam and soft material. For efficient ventilation of roof structures, use a KTV valve without an adapter, for an attic room - a KTV valve with an adapter. In the latter case, the adapter is connected to a pipe that leads to the attic.

In addition, the KTV valve with adapter can also be used to ventilate the sewer riser in regions with a warm climate. Then the corrugated pipe for connection to the sewer riser will have to be ordered additionally. The size of the passage element is 351x266 mm. It is installed on an already finished roof.


Price: 7 650 rub.

Roof valve PELTI - KTV is used for ventilation of roof structures and attic space on pitched roofs made of metal tiles with a profile height of less than 38 mm. For roof ventilation, a KTV valve without an adapter is best suited, for attic spaces a KTV valve with an adapter is best suited. Such an adapter is simply connected to a pipe that leads to the attic. The KTV valve with adapter can also be used to ventilate the sewer riser in regions with warm winters. In this case, a special corrugated pipe for connection to the sewer riser must be ordered separately. The size of the passage element is 355x460 mm. It is installed when laying roofing material.


Price: 2 450 rub.

Ridge valve PELTI-KTV/harja for metal roofing designed to provide ventilation of the roof and attic space. Easily installed on round, triangular and U-shaped skates. It has flexible design and can be mounted on a ridge with a different angle of inclination. It is recommended to observe an interval between the valves of about 3 meters. Valve size - 350x225 mm. The valve opening corresponds to a diameter of 160 mm. It is installed on the finished roof.


Price: 2 000 rub.

The MUOTOKATE – KTV valve can be used for ventilation of roof structures and attic space on pitched roofs made of metal tiles with a tile profile. For roof ventilation, it is advisable to use a KTV valve without an adapter. If it is necessary to ensure the ventilation of the attic space - a KTV valve with an adapter. Such an adapter is connected to a pipe leading to the attic. Another area of ​​application for the KTV valve with an adapter is to ensure ventilation of the sewer riser in regions with very mild winter. In this case, it will be necessary to order a separate corrugated pipe for connection to the sewer riser. The dimensions of the passage element are 330x260 mm. Installation is carried out on the finished roof.

Ventilation outlets Vilpe


Price: 3 600 rub.

The ventilation outlet with a hood 500 mm high is designed to lead pipes to the roof kitchen hood, or exhaust ventilation with duct fan or recuperator. It directs the air flow, which ensures the protection of the entire ventilation system from precipitation and dirt. The outer diameter is 160 mm. The inner pipe has a diameter of 125 mm and is made of high quality galvanized steel. The passage element is ordered separately based on the type of roofing material.


Price: 9 200 rub.

Ventilation outlet with a hood 500 mm high is used to bring kitchen hood pipes to the roof, as well as exhaust ventilation with a duct fan or heat exchanger. It allows you to direct the flow of air, helping to ensure reliable protection ventilation system from the penetration of precipitation and dirt. External diameter - 225 mm. The inner tube is made of galvanized steel. It has a diameter of 160 mm. The passage element must be ordered separately depending on the type of roofing material.

Ventilation of sewer risers Vilpe


Price: 2 400 rub.

Ventilation outlet with reliable thermal insulation is designed for ventilation of the sewer riser in regions with long winter frosts. Insulated 500 mm high. The outer diameter is 160 mm. Thanks to thermal insulation, ice plugs do not form in the pipe, which can disrupt the effective ventilation of the riser. It is necessary to order separately a corrugated pipe for connecting the ventilation outlet to the sewer riser and a pass-through element (based on the type of roofing material).


Price: 1 350 rub.

This ventilation outlet is used to provide ventilation of the sewer riser in regions with warm winter. Outlet uninsulated 500 mm high. In regions with a warm climate, without severe and prolonged frosts, the sewer outlet can be equipped with a deflector cap. Additionally, it is required to order a passage element (depending on the type of roofing material) and a corrugated pipe for connecting the ventilation outlet to the sewer riser.


Price: 2 000 rub.

Corrugated pipe connects the ventilation outlet of the sewer with a sewer riser having a diameter of 110 mm. Made from rubber. Flexible and versatile pipe allows you to bring the riser to the roof in any convenient location. It is allowed to fluctuate the outlet and the sewer riser in the horizontal and vertical plane. If necessary, you can order an adapter for a diameter of 75 mm.

Ventilation hoods Vilpe


Price: 500 rub.

The VILPE-110 deflector cap is designed for pipes with a diameter of 110 mm. It provides the creation of additional traction in the pipe. An uninsulated sewer ventilation outlet with a diameter of 110 mm, equipped with such a cap, can be used for ventilation of the under-roof space. If necessary, the pipe can be cut to the desired height.


Price: 1 050 rub.

The VILPE-160 hood is installed on ventilation outlets with a diameter of 160 mm (eg isolated sewer outlets 110/160 and ventilation outlets 125/160).

The cap prevents precipitation and dirt from entering the ventilation system, while providing additional draft in the pipe.


Price: 1 800 rub.

Vilpe's antenna outlets are designed to provide reliable sealing of antenna roof penetrations, flagpoles and pipes with a diameter of less than 90mm. They are completed with a passage element according to the type of roofing material. In the tone of the roof, you can pick up a plastic collar. A special seal allows the movement of the antenna. It is made from weather and ozone resistant EPDM rubber. The cone-shaped seal can be cut to the required diameter. Strong connection with the antenna barrel is provided with a reliable metal clamp.

Vilpe roof fans with forced ventilation


Price: 17 100 rub.

Fan height 500 and 700 mm, with an outer diameter of 160 mm.

To maintain the necessary air exchange in the interior, the Vilpe E120 P125 fan is used. With the help of the device, it is possible to minimize the formation of condensate and put a barrier for foreign odors. Additional thermal insulation of the fan pipe eliminates the possibility of condensation. Flow air masses passes through an internal galvanized pipe with a diameter of 125 mm.

Depending on the type of roofing used, the passage element is selected.


Price: 21 600 rub.

To create indoors favorable environment and normal air exchange, you can use the Vilpe E 190 R 125 fan. Due to the special, additionally heat-insulating layer on the pipe, it is possible to achieve maximum reduction condensation, to prevent foreign odors from entering the room. The passage of the air flow is carried out through an internal galvanized pipe with a diameter of 125 mm.


Price: 28 800 rub.

Fan height 500 and 700 mm, with an outer diameter of 225 mm.

In order for the interior to be optimal level air exchange, as well as in order to protect the premises from foreign odors, a roof fan Vilpe E220 P / 160 is installed. The device is designed to minimize the possibility of condensation phenomena. For this, the fan pipe has an additional heat-insulating layer. The flow of air masses moves along an internal galvanized pipe, the diameter of which is 160 mm.

The passage element is selected separately, its choice depends on the type of roofing used.


Price: 61 200 rub.

To create optimal air exchange in the premises, to protect them from the penetration of foreign odors and to eliminate the appearance of condensate, a roof fan Vilpe E250 R / 200 is used. Reducing the degree of condensate formation is achieved by additional thermal insulation of the fan pipe. The flow of air masses moves along an internal galvanized pipe with a diameter of 200 mm.

The passage element is selected separately, its choice depends on the type of roofing used.


Price: 0 rub.

Fan height 500 and 700 mm, with an outer diameter of 300 mm.

To create optimal air exchange in the premises, a Vilpe E310 R/200 fan is installed on the roof. Also, the main functions of the fan include reducing the level of condensation and protecting the room from extraneous odors. deal with increased condensate an additional heat-insulating layer of the roof fan pipe helps. The air flow moves along an internal galvanized pipe with a diameter of 200 mm.

The passage element is selected separately, its choice depends on the type of roofing used.


Price: 44 100 rub.

Fireplace fan Vilpe TI-17 is necessary to ensure high-quality draft in the chimney of the stove or in the fireplace. Place of installation - chimney.

Installing a fan is advisable where the fireplace is heated extremely rarely. A damp chimney does not provide the necessary traction, it helps to correct the situation powerful fan- Vilpe TI-17. With the help of the device, it is possible to put a barrier to smoke, increase the degree useful action fireplace or stove, adjust the desired draft. The device is easy to use, does not require special care, has low power consumption.

Advantages of the fan: simple design and long, convenient operation, use quality materials and fast installation.

You can connect the fan with a multi-stage switch or with a thyristor. The device provides smooth adjustment and activation of the fireplace at full capacity. Installing a switch next to the fireplace provides a convenient and quick way to control fan operation.

The fan is installed on a special rubber substrate using metal squares. The fan motor does not require additional maintenance throughout its life. The motor impeller is cleaned at the same time as the pipe is cleaned.

Rated power - 43 W

Maximum temperature level - 200 C

Black colour

Attention! If there is a fire in the fireplace, the fan must be turned on!


Price: 10 620 rub.

Manhole size - 96.3 x 96.3 x 16.0 cm

Hole in the hatch - 60.0 x 60.0 cm

Border flange width - 15.0 cm

For safe operation roof made from roll materials or shingles, it is necessary to use the Vilpe HUOPA roof hatch. The main task of the device is to ensure free penetration into the attic space in terms of fire safety.
The special design of the device is the presence of double grooves that ensure a tight fit of the cover.

Condensate is drained through a special hole through a special groove located on the inner surface hatch covers.

Finnish roof ventilation Vilpe Vent is manufactured at the plant of SK-Tuote OY, which is one of the leaders in the development and production of various accessories for hydro and thermal insulation of the roof. Produced in Finland, vilpe roof ventilation is the ideal solution for climatic conditions on Russian territory. In production roofing accessories vilpe vent uses impact-resistant high-quality polypropylene, which is a material that is resistant to ultraviolet and various kinds mechanical influences.

Thanks to uniform design and great opportunity choosing the color of the accessories, Vilpe vent ventilation gives an attractive and finished look to the roof of the building. Traditionally, the production of roof ventilation is carried out in black, brick, dark red, dark brown and dark green colors. SK-Tuote OY accessories are recommended for high quality roofing.

Roof ventilation from a Finnish manufacturer has some advantages that make it an attractive solution when proper ventilation needs to be done. pitched roof. Firstly, SK-Tuote OY produces all the necessary elements for arranging ventilation in a private house. Secondly, the installation of ventilation of this kind can be carried out on already finished roofs. Ventilation flat roofs will not be exposed to corrosion, and will not lose its attractive appearance under the influence of ultraviolet rays.

Vilpe Vent roofing accessories include: roof penetration, deflectors and valves, household fans, ventilation outlets, roof hatches, antenna outlets, seals for pipes and antennas, ventilation for sewer risers. Roof hatches allow you to organize access to hard-to-reach areas of the roof through the exit through the attic, access to the space of complex roofs and the under-roof area. In addition, roof hatches can serve as fire exits to the roof of the house. Normal air exchange in the room is maintained with the help of household fans, and deflectors and valves are used to remove moisture from attics and attics.

Necessary roof ventilation Vilpe

High-quality installation of any roof and facade cannot do without thoughtful and properly installed roof ventilation. Such important detail Roofing in modern construction helps to perform the following functions:

  • protection of the roof and under-roof space from ice accumulation;
  • ensuring normal and proper air circulation in the room and space under the roof;
  • preventing the accumulation of moisture and preventing the growth of mold and pathogens in too humid air;
  • rotting prevention roofing materials and extending their service life.

Quality ventilation Vilpe

The company "Vekro" represents the Finnish trademark Vilpe, whose ventilation has established itself as a high-quality and reliable product. All components and accessories, which are represented by the Vilpe brand, are very durable and easy to install. Thus, roof ventilation turns out to be reliable and fully performs the functions and tasks assigned to it.

How to buy

All components and accessories presented on the site are available for order. In our company, any buyer can get high-quality advice and make right choice parts for roof ventilation equipment. And Vilpe ventilation is reliable and correct solution all issues related to the provision of under-roof air circulation in the room. All Vilpe roof ventilation in our company is available for order with delivery, and its price will please every customer. For reasonable money, each of you will receive high-quality and durable roof and ventilation in the room.

A roof vent is the end element of a vent or aerator system through which a pipe exits. Products ensure the tightness of the junction of communications with the roof, and also provide an aesthetic appearance node. The so-called fungi protect the ventilation system from precipitation and wind blowing.

The need to pass ventilation pipes through the roof is due to the fact that it is this method that allows you to create natural draft in the system. The location of the output at a height will ensure the creation of a comfortable atmosphere in the room, accelerate the removal of waterlogged and polluted air from the kitchen, bathroom or workshop.

The most important advantage of hood fungi is that they eliminate the need for a bulky brick riser. Hermetic outlet allows pipes to be laid by any convenient way. The use of such a design is much cheaper, less time and money are spent on its installation, turnkey solution does not spoil the appearance of the roof and does not require any maintenance.


Assortment of ventilation outlets for corrugated sheets, rebates, metal tiles, soft roofs

The design of the fungus includes not only the visible part, but also a system of passage and sealing elements, as well as pipes (for individual models). For some products, you can pick up an adapter for use as. In general, the design features of such elements depend on the type of coating on which the installation will be performed.

Our catalog contains outlets of various foreign and domestic brands, including:

  • Finnish. Premium products that have earned the trust of professionals. The manufacturer offers a variety of solutions for the most different roofs;
  • . Budget series, which is made of reliable rubber and silicone. The catalog contains penetrations for cables with a thickness of 6 mm and pipes with a diameter of up to 100 cm. Important distinguishing feature products - heat resistance;
  • . Produced under the Russian brand in Denmark and are advantageous combination reliability and availability. Items are shipped assembled. The catalog contains penetrations for corrugated board;
  • . The outlets of the Russian brand are made from materials that are resistant to fading. The range includes many models for common types of roofing.

To buy an outlet for ventilation pipe on the roof, place an order on our website or provide information about the order by phone.